Commercial hot water heat pump
Hot Water EVI Heat Pump , Air To Water Low Ambient Heat Pump
Hot Water EVI Heat Pump , Air To Water Low Ambient Heat Pump Specifications: Parameters MG-200KFLW Body size(W*D*H) MM 2000*1100*2080 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser shell and coil Thermostatic expansion valve Danfoss AC contactor (220V-38A)*2 Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*10mm2+2*4mm2 20℃ Heating capacity (kW) 81.2 Input power (kW) 21.4 Rated current
Copeland Compressor EVI Low Temperature Heat Pump With IP Grade IPX4
Copeland Compressor EVI Low Temperature Heat Pump With IP Grade IPX4 Specifications: Product model MG-100KFLW MG-200KFLW Standard Configuration Metel plate Galvanized steel/Spray/Gray Galvanized steel/ Spray/Gray Body size(W*D*H) 1580*800*1600 2000*1100*2080 Compressor Copeland ZW61KSE*2 Copeland ZW108KSE*2 Refrigerant R407C/3.3kg*2 R407C/7kg*2 Power supply 380V/50Hz 380V/50Hz Condenser Efficient tank 155HD065*2 shell and coil φ273 162-φ9.52*1250 Economy unit(EVI heating
R407C Refrigerator EVI Heat Pump High Coefficient Of Performance
R407C Refrigerator EVI Heat Pump High Coefficient Of Performance Specifications of EVI Air To Water Heater For Super Cold Region In EU: Model No. #MG-030A -KFLW #MG-030B -KFLW #MG-050- KFLW #MG-100 -KFLW #MG-200 -KFLW 20℃ Heating Capacity(KW) 10.8 11.8 20.6 40.6 81.2 Heating Input Power(KW) 2.81 3.1 5.4 10.7 21.4 Rated Current(A) 12.4 6.2 9 17.6 35.2 COP(Coefficient of Performance) 3.84 3.81 3.81 3.79 3.79 Water Capacity(L/H) 232 254 443 873 1745 -10℃ Heating Capacity(KW) 6.3
12 KW High COP EVI Heat Pump , Heating And Cooling Heat Pump
12 KW High COP EVI Heat Pump , Heating And Cooling Heat Pump Specifications: Model No. MG-030KFXRS Heating Capacity(kW) 12 Heating Input Power(kW) 2.78 COP(Coefficient of Performance) 4.32 Voltage 380V/50Hz Rated Current(A) 7.5 Advised cable 3*2.5mm2+2*1.5mm2 IP Grade (Level of protection) I Level of protection IPX4 Working Condition(℃) -25 to 43 Rated Water Temp.(℃) 55 Max Water Temp.(℃) 60 Hot Water Capacity(L/H) 172 Water Connection Size(mm) DN25 Compressor Copeland Air
Low Temperature EVI Heat Pump Copeland 380V 50HZ Approved EN14511
Low Temperature EVI Heat Pump Copeland 380V 50HZ Approved EN14511 Specifications: Parameters MG-100KFLW Body size(W*D*H) MM 1580*800*1600 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser Efficient tank Thermostatic expansion valve Danfoss AC contactor (220V-18A)*2 Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*6mm2+2*2.5mm2 20℃ Heating capacity (kW) 40.6 Input power (kW) 10.7 Rated
-25 Deg C Low Temperature Heat Pump EVI System For Russia Ukarine Market
-25 Deg C Low Temperature Heat Pump EVI System For Russia Ukarine Market Specifications: Product model PF030-KFLW-S PF030-KFLW PF050-KFLW PF100-KFLW Parameters heating* Heating capacity (kW) 10.5 11.5 18.8 38 Input power (kW) 2.7 2.9 4.8 9.6 Rated current (A) 12.4 5.9 9 17.6 COP 3.89 3.97 3.92 3.96 Production capacity (L/H) 226 247 404 817 heating** Heating capacity (kW) 8.4 9.1 15.0 30.2 Input power (kW) 2.6 2.8 4.7 9.4 Rated current (A) 12.3 5.8 8.9 17.4 COP 3.23 3.25 3.19
Forced Air Hot Water Heating System Air To Water Heat Pump With EN14511
Maximum 40.6KW Heating Forced Air To Hot Water Heat Pump In Iced Area For European Market With EN14511 Test Report Specifications of Power World Maximum 40.6KW Heating Forced Air To Hot Water Heat Pump: Model No. #MG-030A-KFLW #MG-030B-KFLW #MG-050-KFLW #MG-100 -KFLW #MG-200 -KFLW 20℃ Heating Capacity(KW) 10.8 11.8 20.6 40.6 81.2 Heating Input Power(KW) 2.81 3.1 5.4 10.7 21.4 Rated Current(A) 12.4 6.2 9 17.6 35.2 COP(Coefficient of Performance) 3.84 3.81 3.81 3.79 3.79 Water
20.6 KW Low Temperature Air Source Heat Pump with high COP and low noise
20.6 KW Low Temperature Air Source Heat Pump with high COP and low noise Specifications: Product model MG-050KFLW Body size(W*D*H) MM 1110*490*1260 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser Efficient tank Thermostatic expansion valve Danfoss AC contactor (220V-18A) Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*4mm2+2*2.5mm2 20℃ Heating capacity (kW) 20.6 Input power (kW) 5.4
-25 Degree Air To Water EVI Low Temperature Heat Pump With Copeland Compressor
-25 Degree Air To Water EVI Low Temperature Heat Pump With Copeland Compressor Low Temperature Heat Pump Futures: Feature 1) EVI compressor special designed for high COP (Coefficient of Performance): 4.5 even in bad weather condiction or area. 2) Base frame and externel panels made of galvanized powder coated steel 3) Water exchanger equipped with high efficiency tube in shell heat exchanger 4) Reliable compressor with R407C refrigerant 5) Stable water flow switch & backflow
EVI System Low Temperature Heat Pump With Automatic Defrosting
EVI System Low Temperature Heat Pump With Automatic Defrosting Low Temperature Heat Pump Futures: Feature 1) EVI compressor special designed for high COP (Coefficient of Performance): 4.5 even in bad weather condiction or area. 2) Base frame and externel panels made of galvanized powder coated steel 3) Water exchanger equipped with high efficiency tube in shell heat exchanger 4) Reliable compressor with R407C refrigerant 5) Stable water flow switch & backflow proof. 6) Fully
Energy - Saving Air To Heat Water Exchanger Pump For Hot Water Heating System
Hi81.2KW Exhausted Air To Heat Hot Water Exchanger Pump System In Glacial Zone For EU Market With CE and EN14511 Report Specifications of Power World Exhausted Air To Heat Hot Water Exchanger Pump System: Model No. #MG-030A-KFLW #MG-030B-KFLW #MG-050-KFLW #MG-100-KFLW #MG-200-KFLW 20℃ Heating Capacity(KW) 10.8 11.8 20.6 40.6 81.2 Heating Input Power(KW) 2.81 3.1 5.4 10.7 21.4 Rated Current(A) 12.4 6.2 9 17.6 35.2 COP(Coefficient of Performance) 3.84 3.81 3.81 3.79 3.79 Water
Energy Saving EVI Low Temperature Heat Pump With Hot Water Heat Exchanger
EnergySaving 11.8KW EVI Water Heating System In Freez Area with Galvanized Case,Minute Compressor, R407C Refrigerant Oil Specifications of Power World 11.8KW EVI Water Heating System In Freez Area: Model No. #MG-030A-KFLW #MG-030B-KFLW #MG-050-KFLW #MG-100 -KFLW #MG-200 -KFLW 20℃ Heating Capacity(KW) 10.8 11.8 20.6 40.6 81.2 Heating Input Power(KW) 2.81 3.1 5.4 10.7 21.4 Rated Current(A) 12.4 6.2 9 17.6 35.2 COP(Coefficient of Performance) 3.84 3.81 3.81 3.79 3.79 Water
Low Temperature Air Source Heat Pump For Heat Exchanger Hot Water System
Better COP 10.8KW EVI Pump Heater For Snowy Area Hot Water with Galvanised Case, Quiet Compressor, Green Refrigerant Oil Specifications of Power World 10.8KW EVI Pump Heater For Snowy Area Hot Water: Model No. #MG-030A-KFLW #MG-030B-KFLW #MG-050-KFLW #MG-100 -KFLW #MG-200 -KFLW 20℃ Heating Capacity(KW) 10.8 11.8 20.6 40.6 81.2 Heating Input Power(KW) 2.81 3.1 5.4 10.7 21.4 Rated Current(A) 12.4 6.2 9 17.6 35.2 COP(Coefficient of Performance) 3.84 3.81 3.81 3.79 3.79 Water
Hotel / Hospital 40KW Low Temperature Heat Pump , Air To Water Source Heat Pump R407C
40.6 KW Low Temperature Air Source Heat Pump for EU market with EN14511 Specifications: Parameters MG-100KFLW Body size(W*D*H) MM 1580*800*1600 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser Efficient tank Thermostatic expansion valve Danfoss AC contactor (220V-18A)*2 Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*6mm2+2*2.5mm2 20℃ Heating capacity (kW) 40.6 Input power (kW) 10.7
Low Temperature Air Source Heat Exchanger Heat Pump Coefficient Of Performance 3.81
20.6 KW Low Temperature Air Source Heat Pump with high COP and low noise Specifications: Product model MG-050KFLW Body size(W*D*H) MM 1110*490*1260 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser Efficient tank Thermostatic expansion valve Danfoss AC contactor (220V-18A) Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*4mm2+2*2.5mm2 20℃ Heating capacity (kW) 20.6 Input power (kW) 5.4
EVI low temperature heat pump air to water heat pump water heater with EN14511
High COP - 25 Degree C EVI Low Temperature Air Source Heat Pump with TUV ErP CE standard Features : 1.Low temperature Enhanced Vapor Injection compressor technology ( EVI ) guarantee a stable running even at -25 degree., Operation range: -25C~+45Ambient temp 2.Perfect protection design: Anti-frost protection, high/ low pressure protection, water flow protection,high protection, etc.,and automatic-defrost function,assuring the system to run safely and efficiently even in hard
18.8 KW Commercial Heat Pump Water Heater For Hot Water Heating Systems
18.8 KW Commercial Heat Pump Water Heater For Hot Water Heating System Specifications: Product model MG-050KFXRS Standard Configuration Metel plate Galvanized steel/Spray/Gray Compressor Copeland ZW61KAE Refrigerant R407C Power supply 380V/50Hz Condenser Efficient tank 155HD-065 Evaporator L-2/990*1200/φ9.52 Internal Thread/25U pipe Electronic expansion valve DanfossETS6-32 AC contactor German Eton (220V-18A) Motor (with capacitance) 90W*2(5μf) Fan φ490*2 Controller Dual
High Efficiency 38 KW Air Source Heat Pump For Heating And Cooling
High Efficiency 38 KW Air Source Heat Pump For Hot Water And Heating And Cooling Specifications: Parameters MG-100KFXRS Heating capacity (kW) 38 Power consumption(kw) 8.8 COP (Coefficient of Performance) 3.96 Voltage 380V/50Hz Rated current (A) 17.6 IP Grade (Level of protection) IPX4 Anti-electric shock Rate I Working conditon(℃) -7 to 43 Max water temperature(℃) 60 Advised water flux (L/h) 817 Water connection size(mm) φ50 Compressor Copeland Electronic expansion valve
42 KW Hot Water Air Source Heat Pump / Heating And Cooling Heat Exchanger
42 KW Air Source Heat Pump For Hot Water And Heating And Cooling With High COP Specifications: Parameters MG-120KFXRS Heating capacity (kW) 42 Power consumption(kw) 10.8 COP (Coefficient of Performance) 3.89 Voltage 380V/50Hz Rated current (A) 20.7 IP Grade (Level of protection) IPX4 Anti-electric shock Rate I Working conditon(℃) -7 to 43 Max water temperature(℃) 60 Advised water flux (L/h) 903 Water connection size(mm) φ50 Compressor Copeland Electronic expansion valve
38 KW Heating And Cooling Air Source Commercial Heat Pumps For Hot Water
38 KW Air Source Heat Pump For Hot Water And Heating And Cooling With High COP Specifications: Parameters MG-100KFXRS Heating capacity (kW) 38 Power consumption(kw) 9.6 COP (Coefficient of Performance) 3.96 Voltage 380V/50Hz Rated current (A) 17.6 IP Grade (Level of protection) IPX4 Anti-electric shock Rate I Working conditon(℃) -7 to 43 Max water temperature(℃) 60 Advised water flux (L/h) 817 Water connection size(mm) φ50 Compressor Copeland Electronic expansion valve