Commercial hot water heat pump
57Kw Top Discharge Commercial Heat Pump With Cooling And Heating Function
57Kw Top Discharge Commercial Heat Pump With Cooling And Heating Function Specifications of Power World Air Source Heat Pump For Commercial Heating and Cooling: Product model MG-120KFXRS MG-150KFXRS MG-200KFXRS Standard Configuration Metel plate Galvanized steel/Spray/Gray Galvanized steel/Spray/Gray Galvanized steel/Spray/Gray Body size(W*D*H) 1580*800*1600 1580*800*1600 1850*1000*1950 Compressor Copeland ZR72KCE*2 Copeland ZR81KCE*2 Copeland ZW108KAE*2 Refrigerant R407C/3
10.8KW 60 DegC Hot Water Air Source Commercial Heat Pumps for Home Application
10.8KW 60DegC Hot Water Air Source Heat Pump Water Heater For Commercial Projects or Home Application Specifications of Power World 10.8KW 60DegC Hot Water Air Source Heat Pump Water Heater For Commercial Projects or Home Application: Specification of Top Fan Commercial Heat Pump Model No. Unit #PW-030-KFXLR #PW-040-KFXLR #PW-050-KFXLR Power Input KW 2.70 3.60 4.50 Heating Capacity KW 10.80 14.40 18.00 Rated Current Amps 12.2 16.2 20.25 Largest Current Amps 16.2 21.6 27 Power
High COP Geyser Commercial Heat Pumps / Air Source Heat Exchanger Pump R407C
Best COP 42KW Heating Air Source Geyser Furnish Living 60℃ Water with 7year Warranty Compressor, Danfoss Valve & 6T Fans Specifications of Power World 42KW Heating Air Source Geyser: Model No. #MG-100-KFXRS #MG-120-KFXRS #MG-150-KFXRS #MG-200-KFXRS #MG-250-KFXRS Heating Capacity (kW) 38 42 52 72 95 Heating Input Power (kW) 9.6 10.8 13.2 18.2 23.8 COP(Coefficient of Performance) 3.96 3.89 3.94 3.96 3.99 Rated Current(A) 17.60 20.70 25.90 36.10 41.40 Voltage 380V/50Hz 380V/50Hz
EN14511 Commercial Air To Water Heat Pump For Heating / Cooling , Hot Water
38 KW Air Source Heat Pump For Hot Water And Heating And Cooling With High COP Specifications: Parameters MG-100KFXRS Heating capacity (kW) 38 Power consumption(kw) 9.6 COP (Coefficient of Performance) 3.96 Voltage 380V/50Hz Rated current (A) 17.6 IP Grade (Level of protection) IPX4 Anti-electric shock Rate I Working conditon(℃) -7 to 43 Max water temperature(℃) 60 Advised water flux (L/h) 817 Water connection size(mm) φ50 Compressor Copeland Electronic expansion valve
Heating And Cooling Systems Commercial Heat Pumps COP 3.94 For Hospital
52 KW Air Source Heat Pump For Hot Water And Heating And Cooling With High COP Specifications: Parameters MG-150KFXRS Heating capacity (kW) 52 Power consumption(kw) 13.2 COP (Coefficient of Performance) 3.94 Voltage 380V/50Hz Rated current (A) 25.9 IP Grade (Level of protection) IPX4 Anti-electric shock Rate I Working conditon(℃) -7 to 43 Max water temperature(℃) 60 Advised water flux (L/h) 1118 Water connection size(mm) φ50 Compressor Copeland Electronic expansion valve
Commercial Water Heating Exhaust Air Heat Pump With Copeland Scroll Compressor
High COP 38kw Exhaust Air Pump Solution For Commercial Water Heating With Danfoss Valve Green Refrigerant LCD Systems Specifications of Power World Exhaust Air Pump Solution For Commercial Water Heating: Model No. MG-030A-KFXRS MG-030B-KFXRS MG-050-KFXRS MG-060-KFXRS Heating Capacity(kW) 10.5 11.5 18.8 21.8 Heating Input Power(kW) 2.7 2.95 4.8 5.6 COP(Coefficient of Performance) 3.89 3.90 3.92 3.89 Voltage 220V/50Hz 380V/50Hz 380V/50Hz 380V/50Hz Rated Current(A) 12.40 5.90 9
52kW Heating Capacity Commercial Heat Pumps , Air To Water Heating System
52 KW Air Source Heat Pump For Hot Water And Heating And Cooling With High COP Specifications: Parameters MG-150KFXRS Heating capacity (kW) 52 Power consumption(kw) 13.2 COP (Coefficient of Performance) 3.94 Voltage 380V/50Hz Rated current (A) 25.9 IP Grade (Level of protection) IPX4 Anti-electric shock Rate I Working conditon(℃) -7 to 43 Max water temperature(℃) 60 Advised water flux (L/h) 1118 Water connection size(mm) φ50 Compressor Copeland Electronic expansion valve
R407C EVI High Efficiency Commercial Heat Pumps Hot water Heat Pump , White Color
R407C EVI China High Efficiency Air Source Commercial Hot water Heat Pump How Do Air to Water Heat Pumps Work? Air to water heat pumps utilise energy from the air, which is used to generate heat with a water-based heating system. The heat from the air makes the chemical liquid inside the pump evaporate. The compression pump extracts the evaporated liquid from the steam generator and transfers it to a smaller space, forwarding the pressure and temperature of the liquid. When
Energy Saving Air Source Industry Heat Pump With LCD Automatically Control
Energy Saving Air Source Industry Heat Pump With LCD Automatically Control Specifications 1, Good performance, reliable 2, Easy installation, long life, high COP value 3, Competitive price, on time delivery 4. Stable runing and low noise; 5. Control by dual system mode; 6. Copeland scroll Compressor 7. Stock listed company 8. Automatic defrosting Commercial Heat Pumps Parameters: Product model MG-30KFXRS MG-50KFXRS MG-100KFXRS MG-120KFXRS MG-150KFXRS MG-200KFXRS MG-250KFXRS
Heating System Solutions 72KW Air to 60℃ Hot Water with Green Refrigerant Oil , Danfoss Valves & LCD Control Panel
Heating System Solutions 24hour 72KW Air to 60℃ Hot Water with Green Refrigerant Oil, Danfoss Valves & LCD Control Panel Specifications of Power World Heating System Solutions: Model No. #MG-100-KFXRS #MG-120-KFXRS #MG-150-KFXRS #MG-200-KFXRS #MG-250-KFXRS Heating Capacity (kW) 38 42 52 72 95 Heating Input Power (kW) 9.6 10.8 13.2 18.2 23.8 COP(Coefficient of Performance) 3.96 3.89 3.94 3.96 3.99 Rated Current(A) 17.60 20.70 25.90 36.10 41.40 Voltage 380V/50Hz 380V/50Hz 380V
Exhaust Air Heat Pump Copeland Scroll Heat Pump Galvanized Steel Spray Gray
Commercial air source heat pumps R407C air to water heat pump with heating and cooling Specifications: Product model PF030-KFXRS-T-S PF030-KFXRS-T PF050-KFXRS-T PF100-KFXRS/U PF100-KFXRS/V PF120-KFXRS PF150-KFXRS PF200-KFXRS PF250-KFXRS PF300-KFXRS Parameters Heating capacity (kW) 10.5 11.5 18.8 38 38 42 52 76 95 110 Input power (kW) 2.7 2.95 4.8 9.6 9.6 10.8 13.2 19.2 23.8 27.8 Rated current (A) 12.4 5.9 9 17.6 17.6 20.7 25.9 36.1 41.4 52.3 COP (Coefficient of Performance) 3
Efficient Tank Condenser Air Source Heat Pumps Dual System Controller
Efficient Tank Condenser Air Source Heat Pumps Dual System Controller Specifications of Power World High COP Air Source Heat Pump For Commercial Hot Water: Product model MG-120KFXRS MG-150KFXRS MG-200KFXRS Standard Configuration Metel plate Galvanized steel/ Spray/Gray Galvanized steel/ Spray/Gray Galvanized steel/ Spray/Gray Body size(W*D*H) 1580*800*1600 1580*800*1600 1850*1000*1950 Compressor Copeland ZR72KCE*2 Copeland ZR81KCE*2 Copeland ZW108KAE*2 Refrigerant R407C/3.3kg
High Temperature Air Source Heat Pumps Tube In Shell Heat Exchanger
High Temperature Air Source Heat Pumps Tube In Shell Heat Exchanger Specifications of Power World Lowest Cost Forced Air to Water Heat Exchanger For Commercial Hot Water: Product model MG-30KFXRS MG-50KFXRS Standard Configuration Metel plate Powder Coated/ Stainless Steel Powder Coated/ Stainless Steel Body size(W*D*H) 710*710*850 800*800*1100 Compressor Copeland Scroll Copeland Scroll Refrigerant R410a R410a Power supply 220V/50Hz/1Ph 380V/50Hz Condenser Tube in shell Tube
Air To Water DC Inverter Heat Pump Heating and Cooling High Efficiency
Air To Water DC Inverter Heat Pump Heating and Cooling High Efficiency Specification of DC Inverter Heat Pumps D/C inverter air source heat pump (Heating&cooling mode, R410a) Model MG-030BP MG-050BP FOB SHENZHEN USD$ $1,750.00 $2,680.00 Standard components Cabinet/Color Anti-rusting Spray Coating Refrigerant R410A Power Supply 220V~240V/50Hz/1Ph 380V~415V/50Hz/3Ph Compressor Dual-rotary D/C Inverter Compressor Condenser High efficiency tube in shell heat exchanger Evaporator
Radiator Heating Air Source Heat Pumps Hot Water / Heating And Cooling
Radiator Heating Air Source Heat Pumps Hot Water / Heating And Cooling Specifications: Parameters MG-050KFXRS Heating capacity (kW) 18.8 Power consumption(kw) 52 COP (Coefficient of Performance) 3.92 Voltage 380V/50Hz Rated current (A) 9 IP Grade (Level of protection) IPX4 Anti-electric shock Rate I Working conditon(℃) -7 to 43 Max water temperature(℃) 60 Advised water flux (L/h) 193 Water connection size(mm) φ50 Compressor Copeland Electronic expansion valve Danfoss Air flow
Commercial Air Source Heat Pumps R407C , Exhaust Air Heat Pump
Commercial Air Source Heat Pumps R407C , Exhaust Air Heat Pump Specifications of Power World Exhaust Air Pump Solution For Commercial Water Heating: Model No. MG-030A-KFXRS MG-030B-KFXRS MG-050-KFXRS MG-060-KFXRS Heating Capacity(kW) 10.5 11.5 18.8 21.8 Heating Input Power(kW) 2.7 2.95 4.8 5.6 COP(Coefficient of Performance) 3.89 3.90 3.92 3.89 Voltage 220V/50Hz 380V/50Hz 380V/50Hz 380V/50Hz Rated Current(A) 12.40 5.90 9.00 11.20 Advised Cable 3*2.5mm2 3*2.5mm2+2*1.5mm2 3
Home Air Source Heat Pumps / Copeland Scroll Heat Pump 52kw
Home Air Source Heat Pumps / Copeland Scroll Heat Pump 52kw Specifications of Power World Lowest Cost Forced Air to Water Heat Exchanger For Commercial Hot Water: Model No. #MG-100-KFXRS #MG-120-KFXRS #MG-150-KFXRS #MG-200-KFXRS #MG-250-KFXRS Heating Capacity (kW) 38 42 52 72 95 Heating Input Power (kW) 9.6 10.8 13.2 18.2 23.8 COP(Coefficient of Performance) 3.96 3.89 3.94 3.96 3.99 Rated Current(A) 17.60 20.70 25.90 36.10 41.40 Voltage 380V/50Hz 380V/50Hz 380V/50Hz 380V/50Hz
High COP 18.8kw Heat Pump Water Heater with Copeland Scroll
High COP 18.8kw Heat Pump Water Heater with Copeland Scroll Specifications of Power World Air to Water Heating System For Sanitary Use: Model No. MG-030A-KFXRS MG-030B-KFXRS MG-050-KFXRS MG-060-KFXRS Heating Capacity(kW) 10.5 11.5 18.8 21.8 Heating Input Power(kW) 2.7 2.95 4.8 5.6 COP(Coefficient of Performance) 3.89 3.90 3.92 3.89 Voltage 220V/50Hz 380V/50Hz 380V/50Hz 380V/50Hz Rated Current(A) 12.40 5.90 9.00 11.20 Advised Cable 3*2.5mm2 3*2.5mm2+2*1.5mm2 3*4mm2+2*2.5mm2 3
Air Source Copeland Scroll Heat Pump Water Heater IPX4 ECO Compressor
Air Source Copeland Scroll Heat Pump Water Heater IPX4 ECO Compressor Specifications of Power World Air Source Heating Pump For Domestic Hot Water: Model No. MG-030A-KFXRS MG-030B-KFXRS MG-050-KFXRS MG-060-KFXRS Heating Capacity(kW) 10.5 11.5 18.8 21.8 Heating Input Power(kW) 2.7 2.95 4.8 5.6 COP(Coefficient of Performance) 3.89 3.90 3.92 3.89 Voltage 220V/50Hz 380V/50Hz 380V/50Hz 380V/50Hz Rated Current(A) 12.40 5.90 9.00 11.20 Advised Cable 3*2.5mm2 3*2.5mm2+2*1.5mm2 3*4mm2
Copeland Compressor Exhaust Air Heat Pump For Hot Water
Copeland Compressor Exhaust Air Heat Pump For Hot Water Specifications: Parameters MG-030KFXRS MG-030KFXRS Heating capacity (kW) 10.5 11.5 Power consumption(kw) 38 42 COP (Coefficient of Performance) 3.89 3.90 Voltage 220V/50Hz 380V/50Hz Rated current (A) 12.4 5.9 IP Grade (Level of protection) IPX4 IPX4 Anti-electric shock Rate I I Working conditon(℃) -7 to 43 -7 to 43 Max water temperature(℃) 60 60 Advised water flux (L/h) 267 127 Water connection size(mm) φ50 φ50