Refrigeration Solenoid Valve
Honey well Type AEL-1.0 Automatic Expansion Valve AEL-222201 AEL-222211
Honey well Type AEL-1.0 Automatic Expansion Valve AEL-222201 AEL-222211 Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure; Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines. 1. Smallest dimensions2.
Automatic expansion valve Honey well Type AEL- 0.5 AEL-222200 AEL-222210
Automatic expansion valve Honey well Type AEL- 0.5 AEL-222200 AEL-222210 Series AEL Automatic Expansion Valves with fixed orifice and adjustable evaporating pressure; Automatic expansion valves (constant pressure valves) series AEL are used in general refrigeration and for original equipment. For plants with single injected evaporators and without a distributor, such as air conditioners, dehumidifiers, air driers, water coolers or ice-making machines. 1. Smallest dimensions2.
CMV-14S Mueller Type Refrigeration Magnetic Check Valve 7/8'' Solder
CMV-14S Mueller Type Refrigeration Magnetic Check Valve 7/8'' Solder Magnetic type refrigeration check valve is designed for installation in commercial refrigerating systems and in residential or industrial air conditioning plants. They are used to control the unidirectional flow of refrigerant to prevent backflow; the magnetic actuator guarantees a high reliability standard. When you install the refrigeration check valve in the system, it will rapidly balance the high
Mueller Type Refrigeration Magnetic Check Valve CMV-8S 1/2'' Solder
Mueller Type Refrigeration Magnetic Check Valve CMV-8S 1/2'' Solder Magnetic type refrigeration check valve is designed for installation in commercial refrigerating systems and in residential or industrial air conditioning plants. They are used to control the unidirectional flow of refrigerant to prevent backflow; the magnetic actuator guarantees a high reliability standard. When you install the refrigeration check valve in the system, it will rapidly balance the high
Thermostatic expansion valve Danfoss Type TD1 R134a R22 R407C R404A
Thermostatic expansion valve Danfoss Type TD1 R134a R22 R407C R404A TD 1 is a thermostatic expansion valve designed to regulate refrigerant injection into evaporators. The injection depends on the refrigerant superheat at the evaporator outlet, where the bulb must be placed. TD 1 is constructed for hermetic sealed systems and supplied as angleway and straightway version. Application Examples: 1. GDM (Glass Door Merchandiser) 2. Commercial fridge and freezer 3. Heat Pump
Refrigeration Expansion Valve EEV EXV for Mini Split Systems 12VDC
Refrigeration Expansion Valve EEV EXV for Mini Split Systems 12VDC Electronic Expansion Valves (EEV, EXV) are designed for use in air conditioning and refrigeration systems or in heat pumps. The valve controls the automatic adjustment of refrigerant flow rate and makes the system work under optimized conditions for the purpose of fast cooling or heating, precise temperature control and energy saving. The valve can also be used e.g. for suction line pressure controls. These
Danfoss Type SG SGN SGI Sight Glass 1/4'' 3/8'' 1/2'' 5/8'' 7/8'' ODF x ODF
Danfoss Type SG SGN SGI Sight Glass 1/4'' 3/8'' 1/2'' 5/8'' 7/8'' ODF x ODF SG is sight glasses for low pressure application (Max Working Pressure 500 psig). SG is available with flare, solder and socket connections, and with and without moisture indicators. SG and SGR, without moisture indicator, are mainly used to indicate the condition of the refrigerant in the liquid line or the flow in the oil return line from the oil separator. SGI / SGN and SGRI / SGRN are equipped
Danfoss Type SGN SGI Low Pressure Sight Glass 1/4'' 3/8'' 1/2'' Flare int x ext
Danfoss Type SGN SGI Low Pressure Sight Glass 1/4'' 3/8'' 1/2'' Flare int x ext SG is sight glasses for low pressure application (Max Working Pressure 500 psig). SG is available with flare, solder and socket connections, and with and without moisture indicators. SG and SGR, without moisture indicator, are mainly used to indicate the condition of the refrigerant in the liquid line or the flow in the oil return line from the oil separator. SGI / SGN and SGRI / SGRN are equipped
Danfoss Type SG Sight Glasses SGN SGI 1/4'' 3/8'' Flare ext x ext
Danfoss Type SG Sight Glasses SGN SGI 1/4'' 3/8'' Flare ext x ext SG is sight glasses for low pressure application (Max Working Pressure 500 psig). SG is available with flare, solder and socket connections, and with and without moisture indicators. SG and SGR, without moisture indicator, are mainly used to indicate the condition of the refrigerant in the liquid line or the flow in the oil return line from the oil separator. SGI / SGN and SGRI / SGRN are equipped with
Danfoss Type NRV refrigeration check valves for Air conditioning 1/4'' 3/8'' 1/2'' 5/8'' 3/4'' 7/8''
Danfoss Type NRV refrigeration check valves for Air conditioning 1/4'' 3/8'' 1/2'' 5/8'' 3/4'' 7/8'' NRV and NRVH refrigeration check valves can be used in liquid, suction and hot gas lines in refrigeration and air conditioning plant with HCFC. HFC and HC flammable refrigerants. The valves ensure the correct flow direction and prevent back-condensation from a warm part of the system to the cold evaporator. A built-in damping piston makes the valves suitable for installation
Danfoss Type Collector Pressure Regulator NRD12S 1/2'' Solder 020B1132 020B1136
Danfoss Type Collector Pressure Regulator NRD12S 1/2'' Solder 020B1132 020B1136 Condensing pressure regulator, type KVR opens upon a rise in pressure on the inlet side, i.e. when the pressure in the condenser reaches the set value. KVR regulation is dependent only on the inlet pressure. Pressure variations on the outlet side of the regulator do not affect the degree of opening, since type KVR has an equalizing bellows. The effective area of this bellows corresponds to that of
Danfoss Type 034L0025 Evaporation Pressure Regulator 7/8 in Kvp 22
Danfoss Type 034L0025 Evaporation Pressure Regulator 7/8 in Kvp 22 An Evaporator Pressure Regulator (EPR) is a mechanical or electronic valve installed in the suction line of a refrigeration or air-conditioning system. Its primary function is to prevent the pressure (and thus the temperature) inside the evaporator from dropping below a specific, preset minimum. Technical Data: Refrigerants CFC, HCFC, HFC Adjustment range 0 to 5.5 bar, Factory Setting = 2 bar Maximum working
Condensing Pressure Regulator Danfoss Type KVR 22 034L0094
Condensing Pressure Regulator Danfoss Type KVR 22 034L0094 Condensing pressure regulator is used to prevent the condensing temperature in a refrigeration system from dropping too low in a refrigeration system, especially during cold weather. They can be fitted in the hot-gas line downstream of the T-fitting branch to the receiver pressure regulator or in the condensate line. Technical Data: Refrigerants HCFC, HFC and HC: KVR 12-22 HCFC and non-flammable HFC: KVR 28-35
Danfoss Type 034L0045 Crankcase Pressure Regulator KVL 22
Danfoss Type 034L0045 Crankcase Pressure Regulator KVL 22 A CPR or crankcase pressure regulator is nothing more than a pressure reducing valve. When installed on a compressor suction inlet and properly adjusted, the CPR will prevent the compressor suction pressure from ever rising above the CPR's setting. The CPR will help prevent refrigeration compressor from overloading during startup on refrigeration systems that may experience heavy load conditions such as a freezer after
Danfoss Type 034l0049 Crankcase Pressure Regulator KVL 15
Danfoss Type 034l0049 Crankcase Pressure Regulator KVL 15 A CPR or crankcase pressure regulator is nothing more than a pressure reducing valve. When installed on a compressor suction inlet and properly adjusted, the CPR will prevent the compressor suction pressure from ever rising above the CPR's setting. The CPR will help prevent refrigeration compressor from overloading during startup on refrigeration systems that may experience heavy load conditions such as a freezer after
Crankcase pressure regulator Danfoss Type KVL 12 034L0043
Crankcase pressure regulator Danfoss Type KVL 12 034L0043 A CPR or crankcase pressure regulator is nothing more than a pressure reducing valve. When installed on a compressor suction inlet and properly adjusted, the CPR will prevent the compressor suction pressure from ever rising above the CPR's setting. The CPR will help prevent refrigeration compressor from overloading during startup on refrigeration systems that may experience heavy load conditions such as a freezer after
Receiver Pressure Regulator Danfoss Type KVD 12 034L0173 034L0176
Receiver Pressure Regulator Danfoss Type KVD 12 034L0173 034L0176 KVD is a modulating receiver pressure regulator. It opens on falling receiver pressure and bypasses hot gas to maintain the receiver pressure at the regulator setting (adjustable). The receiver pressure regulator KVD opens at a fall in pressure on the outlet side, i.e. when the pressure in the receiver falls below the set value. KVD regulates only in dependence on the outlet pressure. Pressure variations on the
FDF6A FDF6A58 Sanhua Type Solenoid Valve FDF NC Series Valve For Heat Pump
FDF6A FDF6A58 Sanhua Type Solenoid Valve FDF NC Series Valve For Heat Pump Product Features of FDF series solenoid valves: 1. Direct operated or pilot operated, 2 way normally closed solenoid valve. Normally open type is available. 2. For use with non-corrosive refrigerant. 3. Compactly designed for use in small appliances produced in quantity such as room air conditioners, dehumidifiers, heat pumps and ice making machines. 4. Various piping configuration available. Technical
FDF4A Sanhua Type Refrigeration Solenoid Valve 24V 110V 120V 220V 240V
FDF4A Sanhua Type Refrigeration Solenoid Valve 24V 110V 120V 220V 240V FDF series solenoid valves are direct operated or pilot operated solenoid valves, mainly used in refrigerant control of various devices such as refrigerating and freezing systems, air conditioners and heat pumps. * Applicable for all common HCFC, HFC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507, R407A/F, R448A/R449A, R452A, R450A/R513A)* Applicable medium temperature: -30ºC to +120ºC;*
FDF series FDF4A Refrigeration Solenoid Valve For Ice Maker AC220V
FDF series FDF4A Refrigeration Solenoid Valve For Ice Maker AC220V FDF series solenoid valves are direct operated or pilot operated solenoid valves, mainly used in refrigerant control of various devices such as refrigerating and freezing systems, air conditioners and heat pumps. * Applicable for all common HCFC, HFC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507, R407A/F, R448A/R449A, R452A, R450A/R513A)* Applicable medium temperature: -30ºC to +120ºC;*