Refrigeration Spare Parts
4 way reversing valve for air conditioner, (air conditioning valve, HVAC/R part)
DSF4-way Reversing Valve is the component to provide heating and cooling from the system to the conditioned space by reversing the flowing direction of refrigerant, which is used at room air conditioners, packaged and central air conditioners. Our reversing valves are designed for heat-pump systems with the capacity from 0.75PH to 12PH; they are suitable for most refrigerants such as R22. R407C, and R410A. Basic parameter 1.Exteral leakage test pressure: 3.0 Mpa 2.Max
4 way reversing valve coil, air conditioning parts, refrigeration valve coil, ACR part
The coil with 0.5m wire, be using for the 4 way reversing valve. The rated power is 5-8W and the temperature is till to 130oC. The voltage be include AC24V, AC100V, AC115V, AC120V, AC220V/240V, AC277V, DC24V, 50HZ/60HZ.
Refrigeration Filling Valve, (copper charging valve, copper access valve, charge valve)
The access valve be usingfor refrigerator, air conditioner, and auto air conditioner industries. Tube can be soft or hard tube, Different specifications available:1/4,3/16,3/8, 1/2, 5/8, 3/4 tube length can be according to customer's requirements: 40mm,50mm,60mm,70mm,80mm,90mm,100mm,120mm....... with tool or without tool, with head part or without head part. For more details please contact with us.
Refrigeration Access Valve, (brass valve, HVAC/R valve, brass charging valve)
The access valve be usingfor refrigerator, air conditioner, and auto air conditioner industries. Tube can be soft or hard tube, Different specifications available:1/4,3/16,3/8, 1/2, 5/8, 3/4 tube length can be according to customer's requirements: 40mm,50mm,60mm,70mm,80mm,90mm,100mm,120mm....... with tool or without tool, with head part or without head part. For more details please contact with us.
Refrigeration Flare type brass hand valve (shut off valve, HVAC/R part)
and valve ( Flare&ODF Solder) applied to the liquid, air suction and heated air lines of refrigeration units. Basic Features: Available with all fluorinate refrigerants. The valve could be fully closed with minimum torque exerted on the valve board. The three stainless steel shims can effectively prevent leaking during the entire life cycle of the valve. The hidden valve cover helps prevent moisture penetration. Connection size: 1/4", 3/8", 1/2", 5/8", 3/4", 7/8"
Refrigeration flare type sight glass (moisture indicator, HVAC/R part)
sight glass(moisture indicator) is a kind of element which shows the moisture and the flow of refrigerant. Descriptions 1. The content of refrigerant in the line of the system; 2. The content of water in the refrigerant; 3. Indicates the oil level of compressor crooked. 4. SG-series have indicator paper whose color changes can indicate the content of water in the refrigerant; 5. The glasses and the "O" ring can make sure there is no leak of the refrigerant; 6. Max. Working
SHF 3/2 Solenoid Valve (HVAC/R valve, refrigerator spare parts)
SHF Series 2-position 3-way solenoid valve is specific component of refrigerators, freezers and other refrigeration system, which is mainly used to control the flow rate and shift the flow direction of refrigerant in the system, can make each room of the refrigerators, freezers refrigerate separately. Now it mainly used in dual-temperature and dual-control computer-controlled refrigerator. 1. Rated Voltage: AC110V, AC220V, DC24V 2. Rated power: 5W 3. Max. operating pressure:
Ice Machine Evaporator, HVAC/R part
The evaporator be using for all kinds of ice machine. We accept the OEM producing according to samples or drawings. For more details please contact with us or visit our website.
Refrigeration aluminum finned evaporator, HVAC/R part
The freezing evaporator be produced by copper tube and alu. fin. Be using for refrigeration and air conditioning system. We accept the OEM producing according to the drawings or samples.
Refrigeration vibration absorber, anti-vibration tube, refrigeration parts
The vibration absorber be made by copper and steel, be using for the refrigeration equipment. The sizes be from 1/4" to 4-1/8". More details please contact with us.
Ice Maker Evaporator, evaporator
The evaporator be using for all kinds of ice machine. We accept the OEM producing according to samples or drawings. For more details please contact with us or visit our website.
Refrigeration Solder solenoid valve (HVAC valve, air conditioner parts, electric valve)
The Solenoid Valve is a kind of normally closed, two-channel trait, acted as a pilot valve, it usually is applied in the liquid refrigerant or exhausting air and water or compressing air, with the features as below: 1. Nut system with O ring ensures watertight performance and strengthens the watertight performance of the coil. 2. The elaborately designed coil winding conforms to CE161-lstandard and able to remain functioning under extreme conditions. 3. The coil winding can
Refrigeration Flare solenoid valve (HVAC valve, air conditioner parts, electric valve)
The Solenoid Valve is a kind of normally closed, two-channel trait, acted as a pilot valve, it usually is applied in the liquid refrigerant or exhausting air and water or compressing air, with the features as below: 1. Nut system with O ring ensures watertight performance and strengthens the watertight performance of the coil. 2. The elaborately designed coil winding conforms to CE161-lstandard and able to remain functioning under extreme conditions. 3. The coil winding can
Refrigeration Differential pressure controller (HVAC/R parts, pressure switch, AC parts)
Descriptions: 1. For use with fluorinated refrigerants as well as with air and water. 2. Allowable Fluid Temp.: -10℃~+120℃ 3. Differential pressure of the pressure control is asdjustable 4. Novel micro-switch ensures reliable switching 5. Mounting bracket is suitable for different occasions 6. It can be used as protective devices for maintaining oil pressure of compressor for air-conditioning purpose. 7. Two pattern: with or without time delay 8. Delay time 60, 90, 120
Refrigeration D dual pressure controller (HVAC/R parts, pressure switch, AC parts)
Descriptions: 1. For use with fluorinated refrigerants as well as with air and water. 2. Allowable Fluid Temp.: -10℃~+120℃ 3. Various contact functions available. 4. With SPDT contact mechanism. 5. Renovated micro-switch structure ensures the reliable switch function. 6. Manual-controlled and no use of other instruments to have a function test. 7. Flexible mounting plate suits various kinds of application. 8. 1/4, G1/4, capillary or special connection can be available and
Refrigeration S single pressure controller (HVAC/R parts, pressure switch, AC parts)
Descriptions: 1. For use with fluorinated refrigerants as well as with air and water. 2. Allowable Fluid Temp.: -10℃~+120℃ 3. Various contact functions available. 4. With SPDT contact mechanism. 5. Renovated micro-switch structure ensures the reliable switch function. 6. Manual-controlled and no use of other instruments to have a function test. 7. Flexible mounting plate suits various kinds of application. 8. 1/4, G1/4, capillary or special connection can be available and
Refrigeration dual pressure controller (HVAC/R parts, pressure switch, ACR parts)
Descriptions: 1. For use with fluorinated refrigerants as well as with air and water. 2. Allowable Fluid Temp.: -10℃~+120℃ 3. Various contact functions available. 4. With SPDT contact mechanism. 5. Renovated micro-switch structure ensures the reliable switch function. 6. Manual-controlled and no use of other instruments to have a function test. 7. Flexible mounting plate suits various kinds of application. 8. 1/4, G1/4, capillary or special connection can be available and
FDF Series Solenoid Valve (HVAC/R valve, air conditioner spare parts, dehumidity parts, A/C part)
FDF type is a kind of mini-flow solenoid valve, which is mainly used for adjusting the defrosting and controlling the refrigerant flow direction of the refrigeration system. At present it is widely used in air-conditioner, dehumidity unit and ice maker, etc. 1. Rated Voltage: AC110V, AC220V, DC24V 2. Frequency: 50/60Hz 3. Max. operating pressure: 3.0Mpa 4.2Mpa 4. Suitable Refrigerant: R12, R22, R134a, R502, R407c, R410a, etc 5. Fluid permission temperature: -30oC to +120oC 6.
Refrigeration solder type hand valve (shut off valve, HVAC/R parts, brass valve, refrigeration valve)
and valve ( Flare&ODF Solder) applied to the liquid, air suction and heated air lines of refrigeration units. Basic Features: Available with all fluorinate refrigerants. The valve could be fully closed with minimum torque exerted on the valve board. The three stainless steel shims can effectively prevent leaking during the entire life cycle of the valve. The hidden valve cover helps prevent moisture penetration. Connection size: 1/4", 3/8", 1/2", 5/8", 3/4", 7/8"
Refrigeration solder type sight glass (moisture indicator, refrigeration part)
sight glass(moisture indicator) is a kind of element which shows the moisture and the flow of refrigerant. Descriptions 1. The content of refrigerant in the line of the system; 2. The content of water in the refrigerant; 3. Indicates the oil level of compressor crooked. 4. SG-series have indicator paper whose color changes can indicate the content of water in the refrigerant; 5. The glasses and the "O" ring can make sure there is no leak of the refrigerant; 6. Max. Working