Electrical Safety Test Equipment
Vacuum Cleaner Current - Carrying Hose Resistance Torsion Testing Machine IEC60335-2-2 cl.21.104
IEC60335-2-2 cl.21.104 Vacuum Cleaner Current-Carrying Hose Resistance Torsion Testing Machine Functional Overview: This equipment is designed according to the requirements of IEC60335-2-2/GB4706.7:201.103. The vacuum cleaner current-carrying hose twisting test equipment will be used to test the horizontal axis of the current-carrying hose fixing equipment. Horizontal rotation axis forward 5 turns, then reverse 5 turns, cycle test 2000 times, after the test is completed, the
IEC60335-2-2 cl.21.103 Vacuum Cleaner Equipment / Current - Carrying Hose Bending Test Machine
IEC60335-2-2 cl.21.103 Vacuum Cleaner Current-Carrying Hose Bending Test Machine Functional Overview: The equipment is a vacuum cleaner current-carrying hose bending test equipment designed according to the requirements of IEC60335-2-2/GB4706.7:201.103, UL1017-8.13.1.3. The test will be carried out on the pivot arm of the current-carrying hose fixing device. The distance between the arm shaft and the hose into the rigid part is 305 (+0 ~ -0.5) mm, and the other end of the
Instrument Lock Drilling Proof Testing Machine Mechanical Anti - Theft Door Lock Detection Plug Door Lock Detection
Instrument lock drilling proof testing machine mechanical anti-theft door lock detection plug door lock detection 1, Equipment Overview: the lock anti drilling testing machine is mainly used for destructive testing of intelligent electronic locks, mechanical anti-theft locks, plug-in locks and other products. 2, Main technical parameters: 1. Control part: PLC controls destructive test by adding specified pressure to electric drill through air pump. Record the failure time and
IEC60335-2-2- Clause 21.101 Current Carrying Hoses Crushing Tester Resistant To Crushing
IEC60335-2-2-clause 21.101 Current-carrying hoses crushing tester | Current-carrying hoses resistant to crushing IEC60335-2-2-21 .101 Current-carrying hoses shall be resistant to crushing. Compliance is checked by the following test. The hose is placed between two parallel steel plates each having a length of 100 mm, a width of 50 mm and the edges of the longer sides rounded with a radius of 1 mm. The axis of the hose is positioned at right angles to the longer sides of the
EN60900 Figure Indengtation test
The en60900 hand tool high temperature pressure test device is designed and manufactured by Dongguan safety regulations according to the standard en60900 Figure 18.
EN60900 Figure Indengtation test
The en60900 hand tool high temperature pressure test device is designed and manufactured by Dongguan safety regulations according to the standard en60900 Figure 18.The en60900 hand tool high temperature pressure test device is designed and manufactured by Dongguan safety regulations according to the standard en60900 Figure 18.
mask bacteria filtration efficiency key performance indicators (BFE)
1 summarize 1.1 Product introduction ZR - 1000 type mask bacteria filtration efficiency key performance indicators (BFE) detector not only conforms to the requirements of medical surgical masks technology YY0469-2011 appendix B in the test method for filter efficiency (BFE) bacteria first B. 1.1 the requirement of test instruments, but also conforms to the American society for testing material ASTMF2100, ASTMF2101, the requirements of the European EN14683 standards,
Bowl , IEC 60335-2-14-clause 3
Bowl having height of approximately 130 mm and an inner diameter of approximately 170 mm at the top, tapering down to approximately 150 mm at the bottom. Its inner surface is smooth and the wall and bottom blend smoothly
IEC60884-1-figure 11 Arrangement For checking the mechanism force of terminals with and without screw
Arrangement For Checking Damage To Conductors Test Device On Screwless Terminals Weights Product information Standard: IEC60884-1-figure 11,VDE 0620-Bild 9 ,IEC60669-1 Application: This device is use to check whether the terminals with screw and screwless terminals can bears the mechanism force under normal operation. Mainly use to judge whether the design and structure of screw clamping terminals meet the requirement of clamping the conductors without excessive damage. Test
PLC Conventional Cordless Kettle Boil Pour Dry Heating Withdraw Fully Functions Tester
Conventional Cordless Kettle Boil Pour Dry Heating Withdraw Fully Functions Tester Product information: The electric water kettle tester is suitable for comprehensive lifespan testing of various types of Conventional cordless electrothermal kettle,complete simulation of artificial water boiling mode. It is designed and manufactured according to IEC 60335-2-15 clause 19.101, 19.102, 22.106 and etc.The whole without staff care, failure alarm.Each station configured independentl
IEC60335-2-3 Clause 21.101 Electric Iron Drop Tester Checking Mechanical Strength Of Electric Irons
IEC60335-2-3 clause 21.101 Electric Iron Drop Tester checking mechanical strength of electric irons Product information: To check the mechanical strength of electric irons by repeated drop onto a steel plate according to IEC60335-2-3 clause 21.101. The electric iron is operated under normal operation at rated power input and, except for cordless irons; the soleplate temperature is maintained under these conditions throughout the test. 1.steel plate, at least 15mm thick, mass
IEC 60335-2-15:22.106 Electrical Safety Tester For Kettle Plug / Pull Out
IEC 60335-2-15:22.106 Electric Kettle Plug And Pull Out Life Test Machine Function overview: This equipment shall test the structure of the electric kettle coupling according to clause IEC 60335-2-15:22.106 and clauses 19 and 22 of GB4706.19-1999.According to the standard requirements, the pot should be placed on the base at 10 frequency per minute, and pulled out 10,000 times to detect the reliability of the structure. Special, point: The test process is controlled by the
220V 50Hz High Linearity Switching Intelligent DC Power Source For Lab
Switching Intelligent DC Power Source APD2000 Series Product parameter • Input voltage range:1Ø2W+G 110V/220V±10% 220V±10% 3Ø4W+G 220V/380V±10% • CV(Constant Voltage Mode) line regulation≦±0.2% ±6Count rated voltage load regulation≦≤± 0.2% of full scale Ripple&Noise≦10mVrms(≦600V)/ 20mVrms(≦1000V) • Constant current mode line regulation≦±0.5% ±3Count rated voltage load regulation≦≤± 0.3% of full scale • Voltage and Current Resolution: 0.2V 0.01A • CP (constant power) mode
ISO9001 Laboratory Linear Standard DC Power Source Resolution 10mV 1mA
Linear Standard DC Power Source APD1000L Series Product parameter • Input voltage range: 1Ø2W+G 110V/220V±10% 220V±10% 3Ø4W+G 220V/380V±10% • Constant voltage temperature coefficient:50~100ppm/℃ Constant current temperature coefficient:300ppm/℃ • CV(Constant Voltage)Mode line regulation≦0.05%Vmax+3mV load regulation≦0.05%Vmax+5mV Ripple&Noise≦10mVrms(≦600V)/ 20mVrms(≦1000V) • CC(Constant current)Mode line regulation≦0.05%Vmax+3mV load regulation≦0.05%Vmax+5mV Ripple&Noise
CC CV CP Mode DC Power Source With IGBT Fast Switch
Switching Standard DC Power Source APD1000 Series Product parameter • Input voltage range:1Ø2W+G 110V/220V±10% 220V±10% 3Ø4W+G 220V/380V±10% • CV(Constant Voltage) Mode line regulation≦±0.02% ±6Count load regulation≦≤± 0.05% of full scale Ripple&Noise≦0.1%RMS • CC(Constant current) mode line regulation≦±0.05% ±3Count load regulation≦≤± 0.15% of full scale Ripple&Noise≦0.3%RMS • CP (constant power) mode line regulation≦±0.05% ±6Count load regulation≦≤± 1% of full scale •
IP55 28.5V 270V DC Aviation Ground Power Supply
Aviation Power APA5000 Series(DC) Product parameter The new APA5000 series DC aviation ground power supply is specially designed to provide external power supply for the production, inspection, maintenance and maintenance of new generation aircraft such as civil aviation passenger aircraft and military aircraft. Product pure digital measurement and control technology, LED/LCD screen display,novel and beautiful shape, reasonable structure design, high stability and reliability
IP54 EF Signal Interlocking AC Aviation Power Supply
Aviation Power APA5000 Series(AC) Product parameter • LED / LCD display, clear and intuitive • Higher power density, smaller size, lighter weight, space saving and easy to move • The protection level is as high as IP54, and the whole machine parts are treated with three preventive measures. working temperature-40℃~50℃ • There are two types of aircraft, vertical type and Trailer type, which are convenient for airport/hangar moving or fixed-point use. • Excellent overload
45 - 500Hz Output Intelligent Linear AC Power Source
Linear Intelligent AC Power Source APA2000 Series Product parameter • Input voltage range:Single phase 195~245V Three phase 340V~420V • Input frequency range:50/60Hz±5% • Output voltage range:Single phase 0~300V (0~600V Match) Three phase 0~520V (0~1040V Match) • Output frequency range:45~500Hz • Waveform Distortion≤0.3% Load Regulation≤0.5% Frequency stability≤0.01% • Three-phase phase angle can be adjusted (0~120 degrees),each phase in use can independently adjust voltage
RS232 / RS485 Communication Switching AC Power Source 195 - 245V 340 - 420V
Switching Intelligent AC Power Source APA2000 Series Product parameter • Input voltage range: Single phase 195~245V Three phase 340V~420V • Input frequency range: 50/60Hz±5% • Output voltage range: Single phase 0~300V (0~600V Match) Three phase 0~520V (0~1040V Match) • Output frequency range: 45~500Hz • Waveform Distortion≤1% Load Regulation≤1% Frequency stability≤0.01% simulate the test environment and power grid situation Product details High Performance • The maximum
Linear Standard AC Power Source With Low Distortion Interference
Linear Standard AC Power Source APA1000L Series Product parameter • Input voltage range: Single phase 195~245V Three phase 340V~420V • Input frequency range: 50/60Hz±5% • Output voltage range: Single phase 0~300V (0~600V Match) Three phase 0~520V (0~1040V Match) • Output frequency range: 45~500Hz • Waveform Distortion≤0.3% Load Regulation≤0.5% Frequency stability≤0.01% • Three-phase phase angle can be adjusted (0-120 degrees), each phase in use can independently adjust