Single Phase 600KVA Three Phase 2000KVA Switching AC Power Source
Switching Standard AC Power Source APA1000 Series Product details High Performance • The maximum capacity of single-phase power supply can reach 600KVA;three-phase power supply can reach 2000 KVA • High crest factor 3.5:1 • Fast response, suitable for special load. Low Distortion Interference,Complete Input/Output Isolation. • Terminal voltage feedback compensation function to ensure no error in test power • Set the starting angle of waveform (0-359 degrees)and synchronous
IEC60065 Dielectric Strength Test Equipment , Dielectric Strength Tester KP-DST
Dielectric Strength Tester Items Model Description Standard Dielectric strength tester KP-DST pole diameter: 5 ± 0.1mm Metal club weight: 100 ± 2g Max measure rang: 20mm Max strength: 35mm Standard: IEC60065, GB8898, UL1310 IEC60065
IEC60335-2-14 Dry sand
IEC60335-2-14 Dry sand Dry sand having a grain size between 170 μm and 250 μm Weight: 2kg
IEC60335-2-14 clause 3 Cylindrical bowl
IEC60335-2-14 clause 3 Cylindrical bowl Cylindrical bowl of approx. capacity 1 Lt. and inner diameter 110mm
IEC 60601-1 Leakage Currents Network Electrical Safety Test Equipment
IEC 60601-1 Leakage Currents network Calibration certificate
IEC 60335-2-3 Simulated Hand Feeler Gauge Steel Material
IEC 60335-2-3 Simulated Hand,Feeler Gauge IEC 60335-2-3-Figure 102 Simulated hand and Figure 103 Feeler gauge 22.1 3 Replacement: 1 3 Appliances shall be constructed so that when handles are gripped in normal use, contact is unlikely between the operator's hand and parts that could be unintentionally touched having a temperature rise exceeding the value specified in Table 3 for handles which are held for short periods only in normal use and Table 1 01 for surfaces adjacent to
ISO 6941-Fig1 Bunsen Burner
ISO 6941-Fig1 Bunsen Burner
15KVA Electrical Safety Test Equipment Programmable AC Power Source
Programmable AC Power Source Model:KPAFC-215 Output capacity:15KVA Working:IGBT/PWM pulse width adjustment mode Input Power:1Ф2W+G 110V/220V±10% 50Hz/60Hz±5% Output Frequency:50,60,45-65Hz Frequency Stability:≤0.01% Output Voltage:0-150V/0-300V Output Current:126/63 Load Regulation:≤1% Waveform Distortion:≤1%(full load2%) Meter Display LED: Display voltage, current, frequency (power selection, power factor display) Protective Device:Overload, overcurrent, overtemperature,
IEC 60320 / IEC60884 Electrical Safety Test Equipment , Plug Withdrawal Force Tester
IEC 60320/IEC60884 Plug Withdrawal Force Tester Details this device meet the requirements of GB2099.1-2008 Fig 16, IEC 60320 and IEC 60884 clause 20 and 21 fig 16, use to test the plug withdraw force. What is the IEC 60320 Withdrawal Force Test? Interpower Corporation uses the 60320 gauges to verify proper withdrawal forces of the connectors and proper positioning of internal connections; thus ensuring loose connections and arching do not occur. What are the requirements? IEC
250VAC IEC60335-1 Flexing Test Apparatus 4 Station
4 Station Flexing Test Apparatus Instrument Introduction 1.1 Main uses This instrument is mainly used to test the flexural fatigue strength of AC power cords and plug leads. It is suitable for rocking motion testing of plug power cords under a certain load. The instrument has no-load (only measures life, does not make open circuit judgment) On-off (makes open circuit judgment), external load (also equipped with load machine, L, N line with large current and voltage load, can
IEC 60335-2-25 Clause 32 Microwave Survey Meter,Survey Meter ,Micro Wave Leakage Tester
IEC 60335-2-25, 6th Edition (2010) - A1/2014 - A2/2015 Household and similar electrical appliances – Safety – Part 2-25: Particular requirements for microwave ovens, including combination microwave ovens IEC 60335-2-25-clause 32- Microwave Survey Meter Product parameters 1. Display mode: LCD 5-bit display. 2. Working environment: -10℃~40℃, humidity less than 80%. 3. Low voltage display: Please replace the battery when the LCD screen displays "EEEEE" symbol. 4. Power supply:
IEC60745-2-5 Lower Guard Durability Test And Close Time Test Equipment With Circular Saw At A 90°Cut
IEC60745-2-5 Lower Guard Durability Test and Close time Test Equipment with Circular Saw at a 90° cut Product information: This device conforms to the standard requirement of EN 60745-2-5:2010 clause 19,IEC60745-2-5:2003 and Annex BB. It is used to test the Durability Test and Close time Test for the lower guard. The saw is to be set for a 90°cut and oriented in the horizontal plane. The lower guard is to be cycled from the full closed position to the maximum open position
IEC60335-2-89 Clause 15 Figure 101 Water Spillage Test Apparatus For Testing Refrigerating Appliances
IEC60335-2-89 Clause 15 Figure 101 Water Spillage Test Apparatus For Testing Refrigerating Appliances Applacation:This water spillage test apparatus is designed and manufacture according to IEC60335-2-89 clause 15 figure 101 and other similar international standards. It is used for for testing refrigerating appliances and consists of the vessel, removable bridge support, release pin, and displacement block. Techincal Parameters: Displacement block volume 140 ml ± 5 ml
IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device
IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device Comply with standards: EN 60745-2-5: 2010 Annex M21.18, Annex M21.18.301, Annex M21.203, Annex M21.301, figure M.301, IEC60745-2-5:2003 Annex BB.20.102, EN 60745-2-5:2010 clause 17.101 and clause 19.102.3. Model:YW-1185 Purpose: Test the mechanical strength, durability test and recovery time test of the lower protective cover. Sample range: circular saw Structure and function: The circular
IEC60745 Electric Hammer Durability Test Apparatus
IEC60745 Electric Hammer Durability Test Apparatus Standard: IEC60745-2-1, IEC60745-2-6 Model:YW-1186 Purpose: used for the test of the durability of hand-held electric tools below 2.5KW Sample range: electric drill and impact drill and electric hammer Structure and function: The device is used for the standard IEC60745-2-6 Figure 103. Load the electric hammer or electric drill to make it run intermittently, and test the electric hammer or electric drill in normal use,whether
30K Air Conditioner Air Enthalpy Method Calorimeter Energy Efficiency Temperature Humidity Test Chamber For Household
30K Air Conditioner Air Enthalpy Method Calorimeter Energy Efficiency Temperature Humidity Test Chamber For Household Charter 1 Laboratory General Introduction Outline This air enthalpy method calorimeter lab designed and manufactured by Anhui KingPo ZhiRui technology limited company consists of an indoor side room and an outdoor side room. The refrigerating capacity, heating capacity and other performances of an air conditioner are tested by means of testing the lab
Test System for Conductive Harassment and Disturbance of RF Field Induction CRF61006A/B
Test System for Conductive Harassment and Disturbance of RF Field Induction CRF61006A/B CRF61006A /B radio frequency conduction immunity test system, according to the IEC61000-4-6 standard integrated conduction sensitivity test system, meet the CS114. of GB /T17626.6/ automotive electronic BCI/ national military standard Meet the criteria: IEC /EN 61000-4-6GB/T17626.6ISO11452-4MIL-STD461E Product characteristics: ■ frequency range 150 kHz-230MHz, frequency resolution 1 Hz ■
Diameter 60mm Test Rod , EN 60335-2-30 Surfaces That Are Accessible To The Test Rod
Diameter 60mm Test Rod , EN 60335-2-30 Surfaces that are accessible to the test rod Product Description: 1. According To Standard: EN 60335-2-30 2. It is used to the protective performance check of the apparatus structures and shells which is easy to access live parts Spectifications: Probe diameter 60mm Probe length 50mm Baffle plate diameter 100mm Baffle plate thickness 10mm Packaging and Shipping 1. Aluminium box and carton box, careful and tight package, make sure the
Touch Screen Stray Surge Generator DS28-100S
Stray surge generatorDS28-100S Military vehicle 28 V DC power supply characteristic parameter tester, according to the GJB298-1987 design through the computer control DC power supply high-voltage, normal, low-voltage power output, complete the vehicle electrical system in a fault-free, single fault, start-up disturbance surge simulation pressurization experiment, voltage spike generator according to the requirements GJB298 the national army standard design. Meet the criteria:
Peak Voltage , Over / Under Voltage Generator SUG181A/B
Peak voltage, over/under voltage generator SUG181A/B the SUG-181A spike voltage generator is designed according to the requirements of the GJB181 standard. during the flight of the aircraft, the execution of the mission and other functions, the power supply system must guarantee the normal working state when performing various scheduled tasks. the main function of the product is to generate a spike signal, which can apply 120 positive and negative alternating voltage spike