KingPo Technology Development Limited
                                                                                                           
Verified Supplier
26 Years
Since 2000
Menu
Home Products Medical Test Equipment

Medical Test Equipment

China ISO594-1 Fig 3b Ring Gage For Male Luer Connectors for sale Video

ISO594-1 Fig 3b Ring Gage For Male Luer Connectors

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO594-1 Fig 3b RING GAGE FOR MALE LUER CONNECTORS ISO594/1 Fig 3a or Fig 3b RING GAGE FOR MALE LUER CONNECTORS ISO 594 Has Been Replaced ISO 80369-7 Foreword ISO 80369-7:2016 cancels and replaces the first edition ISO 594-1:1986 and the second edition of ISO 594-2:1998, clauses, subclauses, tables, figures, and annexes of which have been consolidated and technically revised. The new ISO 80369-7 specification does not define any gauges. We still offer the ISO 594 Conical Ring

China IEC 60601-1 Grips And Other Handling Devices-7 Cm Strap Tester for sale Video

IEC 60601-1 Grips And Other Handling Devices-7 Cm Strap Tester

Price: Negotiable
MOQ: 1
Delivery Time: Negotiable

IEC 60601-1Grips and other handling devices-7 cm strap tester Carrying handles or grips furnished on PORTABLE ME EQUIPMENT shall withstand loading as described in the following test: The handles and their means of attachment are subjected to a force equal to four times the weight of the ME EQUIPMENT in any direction of NORMAL USE and transport. If more than one handle is furnished on PORTABLE ME EQUIPMENT , the force is distributed between the handles. The distribution of

China C.4 Male Luer Reference Connector for sale Video

C.4 Male Luer Reference Connector

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector and C.4 Male Luer Reference Connector ISO 80369-7 C.4 Male Luer Reference Connector Compatibility/Interchangeability: Between ISO 594/2 Fig 7 and ISO 80369-7 Fig C.4 The ISO 594/2 Figure 7 Male Luer Reference Conical Fitting is replaced by ISO 80369-7 Fig C.4 Male Luer Reference Connector. The ISO 80369-7 Figure C.4 is identical to the ISO 594/2 Figure 7 Reference Fitting. ISO 80369-7 Fig C.4 and ISO 594/2 Fig 7 are

China ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material for sale

ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO 80369-7 FIGURE C.4 and C.6 MALE LUER REFERENCE CONNECTOR ISO 80369-7:2016 cancels and replaces the first edition ISO 594-1:1986 and the second edition of ISO 594-2:1998, clauses, subclauses, tables, figures, and annexes of which have been consolidated and technically revised. Because of this, ISO 594 connections must be tested per ISO 80369-7 requirements. Read: Discussion on the change. Compatibility/Interchangeability... Between ISO 594/2 Fig 7 and ISO 80369-7 Fig C.4

China Energy Saving Mask Tester Electrical Safety Test Equipment Esalt Aerosol Generator for sale

Energy Saving Mask Tester Electrical Safety Test Equipment Esalt Aerosol Generator

Price: to be quoted
MOQ: 1
Delivery Time: 30 working days

ZR-1310model salt aerosol generator Product introduction ZR - 1310 salt aerosols generator is the use of collison nozzle will have a certain specific concentration NaCl solution after spray drying, particle size and concentration of aerosol dedicated instruments, built-in clean air compressors, dryers and more nozzle valve, electrostatic neutralizer, output aerosol concentration in 100 L/min to 1000 L/min air flow, be able to reach 100 mu g/L ~ 10 mu g/L, output aerosol

China Mask Virus Filtration Efficiency VFE Detector With High Brightness Color Touch Screen for sale

Mask Virus Filtration Efficiency VFE Detector With High Brightness Color Touch Screen

Price: to be quoted
MOQ: 1
Delivery Time: 30 working days

KP-1000A mask virus filtration efficiency (VFE) detector Product introduction KP – 1000A mask the virus filtration efficiency (VFE) detector as the main performance index conforms to YY/T1497-2016 medical respirator material virus filtration efficiency evaluation phi-x174 phage test method, with double pneumatic contrast sampling method at the same time, improve the precision of sampling, applicable to the metrological verification department, research institutes, mask

China Computer Control Mode Mask Resistance Tester Timing Accuracy  0.1s for sale

Computer Control Mode Mask Resistance Tester Timing Accuracy 0.1s

Price: To be quoted
MOQ: 1
Delivery Time: 30 working days

Mask resistance tester 1.Test standard: yy0469-2011 medical surgical mask Differential pressure tester is used for pressure difference detection of surgical masks. The equipment is equipped with software, which can display pressure curve in real time, output test report and save test data. Meet the test standard yy0469-2011 surgical mask 5.7. YY/ t0969-2010, ventilation resistance 5.6 2. Features of equipment 1. The equipment is equipped with an air pump to simulate

China ISO80369-3 Figure C.4 Male Reference CONNECTOR For Testing Female ENTERAL CONNECTOR For Separation From Axial Load for sale

ISO80369-3 Figure C.4 Male Reference CONNECTOR For Testing Female ENTERAL CONNECTOR For Separation From Axial Load

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO 80369 - 3 2016 Small bore connector for liquids and gases in healthcare application - Part 3 Figure C.4 – Male reference CONNECTOR for testing female ENTERAL CONNECTOR for separation from axial load and resistance to overriding

China ISO5356-1 Figure A.1 30mm Plug And Ring Test Gauges For Testing Anaesthetic And Respiratory Equipment for sale

ISO5356-1 Figure A.1 30mm Plug And Ring Test Gauges For Testing Anaesthetic And Respiratory Equipment

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO 5356-1 Anesthetic and Respiratory Equipment – Conical Connectors – Part 1: Cones and Sockets ISO 5356-1 Introduction In clinical practice, several breathing attachments used in anaesthetic and respiratory equipment may have to be joined together to provide a suitable breathing system. Items of medical equipment, such as a humidifier or a spirometer, are often incorporated into the breathing system which may also be connected to an anaesthetic-gas scavenging system.

China ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector For Testing Female Luer Connectors Leakage for sale

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector For Testing Female Luer Connectors Leakage

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO 80369-7:2017 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications NOTE 1 Cone taper (0,06:1). NOTE 2 R may be 0,5 mm (maximum) × 45° chamfer. The minimum length of the male taper of 10,5 mm is required for testing non-interconnectable characteristics. A minimum length of the male taper of 7,5 mm may be used for the performance tests of Clause 6. ISO 80369-7-Figure C.2 — Male reference luer

China HME Moisture Loss Tester - ISO 23328-1 Conditioning Apparatus For BSF for sale Video

HME Moisture Loss Tester - ISO 23328-1 Conditioning Apparatus For BSF

Price: Negotiable
MOQ: 1
Delivery Time: 30 days

1. Overview: The HME testing equipment is developed and designed according to ISO 9360-1 and ISO 23328-1. This equipment is mainly used to test the performance of the heat and moisture exchanger that simulates the human body, mainly measuring the water loss value during the use of the HME. 2. Specifications: The instrument is based on the standards ISO 9360-1, ISO23328-1; The instrument is mainly used to test the water loss of heat and moisture exchangers (HME) used in

China ISO5356-1-15mm Gauge For Testing Anaesthetic And Respiratory Equipment for sale

ISO5356-1-15mm Gauge For Testing Anaesthetic And Respiratory Equipment

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO 5356-1 Anesthetic and Respiratory Equipment – Conical Connectors – Part 1: Cones and Sockets ISO 5356-1 Introduction In clinical practice, several breathing attachments used in anaesthetic and respiratory equipment may have to be joined together to provide a suitable breathing system. Items of medical equipment, such as a humidifier or a spirometer, are often incorporated into the breathing system which may also be connected to an anaesthetic-gas scavenging system.

China ZR-1210 Model  Respirator Resistance Detector With High Definition LCD Liquid Crystal Display for sale

ZR-1210 Model Respirator Resistance Detector With High Definition LCD Liquid Crystal Display

Price: to be quoted
MOQ: 1
Delivery Time: 30 working days

ZR-1210model respirator resistance detector Product introduction Zr-1210 respirator resistance tester is used to measure the inspiratory and expiratory resistance of the mask under specified conditions.It is applicable to the inspection and inspection of mask products by mask manufacturers and national labor protection equipment inspection institutions. Executive standard GB 2626-2019 Respiratory protective self-absorption filter respirator against particulate matter

China Automatic Constant Current Control Mask Tester ZR-1200 Model Mask Resistance Tester for sale

Automatic Constant Current Control Mask Tester ZR-1200 Model Mask Resistance Tester

Price: to be quoted
MOQ: 1
Delivery Time: 30 working days

ZR-1200model mask resistance tester Product introduction Zr-1200 mask resistance tester conforms to yy0469-2011 technical requirements for surgical masks.When different airflow flows through a certain area of the mask, the pressure at both ends of the mask can be detected to detect the resistance of the mask material. Executive standard YY/0469-2011 Technical requirements for surgical masks for medical use YY/T 0969-2013 Disposable surgical mask Related intellectual property

China ISO 80369-7 Fig C.2 Male Reference Luer Slip Connector For Testing Female Luer Connectors For Leakage for sale Video

ISO 80369-7 Fig C.2 Male Reference Luer Slip Connector For Testing Female Luer Connectors For Leakage

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO 80369-7 Fig C.2 Male Reference Luer Slip Connector for testing female Luer Connectors for leakage Escape Clause: ISO 80369-7; Page 24; Annex C; Figure C.2; Note 2 states: The minimum length of the female taper of 10,5 mm is required for testing non-interconnectable characteristics. A minimum length of the female taper of 7,5 mm may be used for the performance tests of Clause 6. What they are saying here is that if you use an ISO 594/1 Fig 5 Reference Fitting with a

China Loading pad | IEC60601-2-52-Figure 201 .1 04 Loading pad for sale

Loading pad | IEC60601-2-52-Figure 201 .1 04 Loading pad

Price: To be quoted
MOQ: 1
Delivery Time: Negotiable

Loading pad | IEC60601-2-52-Figure 201 .1 04 Loading pad 201 .5.1 02 Loading pad The loading pad (see Figure 201 .1 04) is a rigid circular object, (355+/–5) mm in diameter, the face of which has a convex spherical curvature of 800 mm radius with a 20 mm front edge radius. Figure 201 .1 04 – Loading pad

China Cone tool | IEC60601-2-52-Figure 201 .103 a cone tool for sale

Cone tool | IEC60601-2-52-Figure 201 .103 a cone tool

Price: To be quoted
MOQ: 1
Delivery Time: Negotiable

Cone tool | IEC60601-2-52-Figure 201 .103 a cone tool Key 1 Total weight 5,1 kg ±0,05 kg 2 Marked centre line 3 Surface roughness 1 ,6 4 Drilling hole for weight adjustment Figure 201 .1 03 a) – Cone tool schematic

China GB 19083-2010 Electrical Safety Test Equipment Mask Tightness Tester for sale

GB 19083-2010 Electrical Safety Test Equipment Mask Tightness Tester

Price: to be quoted
MOQ: 1
Delivery Time: 30 working days

ZR – 1220 model Mask tightness tester Product introduction ZR - 1220 type respirator fit tester is a mask/respirator fit test of special equipment, at the same time compatible with OSHA and GB GB 19083-2010 medical respirator technical requirements of the respirator fit test on, widely applicable to mask manufacturers, the national labor protection articles inspection institution to related the mask products testing and inspection. Executive standard GB 19083-2010 Technical

China Diameter ø25mm Mask Resistance Tester High Flow Control Precision for sale

Diameter ø25mm Mask Resistance Tester High Flow Control Precision

Price: to be quoted
MOQ: 1
Delivery Time: 30 working days

Zr-1200model mask resistance tester Product introduction Zr-1200 mask resistance tester conforms to yy0469-2011 technical requirements for surgical masks.When different airflow flows through a certain area of the mask, the pressure at both ends of the mask can be detected to detect the resistance of the mask material. Executive standard YY/0469-2011 Technical requirements for surgical masks for medical use YY/T 0969-2013 Disposable surgical mask Related intellectual property

China 500L Mask Tester Self Cleaning Electrical Safety Test Equipment Respirator Particle Protection Effect Detector for sale

500L Mask Tester Self Cleaning Electrical Safety Test Equipment Respirator Particle Protection Effect Detector

Price: to be quoted
MOQ: 1
Delivery Time: 30 working days

Respirator particle protection effect detector 1 Product introduction ZR - 1002 masks particle detector is protective effect on volume of 500 l self-purification test chamber was gb head mould, will be waiting for inspection masks worn on the head, by any quality median diameter was (0.6 + / - 0.050 mu m, in the salt concentration of 20 mg/m3 aerosols and mass median diameter was (0.3 + 0.050) microns, concentration of 20 mg/m3 of oily aerosol net input from the test chamber,