Medical Test Equipment
Surgical Mask Tester Surface Moisture Permeability Tester Height Adjustable Manual Control
Moisture permeability tester Test standard: Surgical mask Synthetic blood penetration test for surgical masks synthetic blood penetration test for surgical masks can output test reports and store test data. GB 19083-2003-2011 GB/T 4745 requirements. Characteristics of the equipment 1. Configure funnel for detection. 2. The height can be adjusted within a certain range. Technical parameters of detector 1. Test height: 150±2mm. 2. Funnel height: 195±10mm. 3. Funnel diameter:
Color Touch Screen Electrical Safety Test Equipment Bacterial Filtration Efficiency BFE Tester
Bacterial Filtration Efficiency (BFE) tester The main performance indexes of the mask bacterial filtration efficiency (BFE) tester not only meet the requirements of the test instrument of appendix B bacterial filtration efficiency (BFE) in YY0469-2004, but also meet the requirements of ASTM F2100, ASTM F2101, European EN14683 of the American Institute of Testing Materials. On this basis, innovative improvements have been made to improve the accuracy of the sampling by using
IEC60601-1-Figure 33 IEC60601-Clause 9.8.3.3 Load Tester With MITSUBISHI PLC
Body Upper-Carriage Module-IEC60601-1-Figure 33 , IEC60601-clause 9.8.3.3 loading tester 9.8.3.3 * Dynamic forces due to loading from persons Where dynamic forces (due to sitting down, standing up, PATIENT handling PROCESS or the like) can be exerted on ME equipment parts intended to support or suspend a PATIENT or OPERATOR in NORMAL USE, the ME EQUIPMENT shall maintain BASIC SAFETY and ESSENTIAL PERFORMANCE. Compliance is checked by the following test: Prior to performing
ISO 80369-3 Male Luer Gauge for Female Enteral Connector Testing
ISO80369-3 Figure C.3 Gauge Male Reference CONNECTOR For Testing Female ENTERAL CONNECTOR For Leakage Product Specifications Brand Name Kingpo Material Hardness Steel Standard ISO 80369-7 Hardness HRC58-62 Warranty 1 Year Product Name LUER GAUGE Product Description ISO 80369-3 2016 Small bore connector for liquids and gases in healthcare application - Part 3. Figure C.3 - Male reference CONNECTOR for testing female ENTERAL CONNECTOR for leakage, disconnection by unscrewing,
ISO5356-1 Figure A.1 8.5 mm Plug And Ring Test Gauges For Testing Anaesthetic And Respiratory Equipment
ISO 5356-1 Anesthetic and Respiratory Equipment – Conical Connectors – Part 1: Cones and Sockets ISO 5356-1 Introduction In clinical practice, several breathing attachments used in anaesthetic and respiratory equipment may have to be joined together to provide a suitable breathing system. Items of medical equipment, such as a humidifier or a spirometer, are often incorporated into the breathing system which may also be connected to an anaesthetic-gas scavenging system.
IEC60601 / IEC60990 Contact Current-Terminal Discharge Tester Technical Specification
601 / 990 Contact current-terminal discharge tester Technical specification Type 601 Contact current-terminal discharge tester... 1, overview This instrument is a , information technology equipment and electronic and electrical contact current, leakage current and terminal discharge instrument.Contact current (leakage current) and terminal discharge volume are general measuring instruments in the laboratory engaged in electronic and electrical product safety testing, widely
ISO 8185 Figure DD.1 Temperature Sensor Gauge , Respiratory Tract Humidifiers Connectors Gauge
ISO8185 Respiratory tract humidifiers for medical use — Particular requirements for respiratory humidification systems Temperature sensors and mating ports DD.1 Dimensional requirements for temperature sensors Check dimensional accuracy as follows: a) Maintain the temperature sensor and gauge at ambient air temperature. b) Ensure that the axial length of the taper of temperature sensors is at least 10,5 mm. c) Engage the temperature sensor with the ring gauge shown in Figure
ISO8638 Blood Port Connectors Gauges , ISO8638 Extracorporeal Blood Circuit For Haemodialysers Connectors Gauges
ISO8638 Cardiovascular implants and extracorporeal systems — Extracorporeal blood circuit for haemodialysers,haemodiafilters and haemofilters Figure 3 — Test device used for ISO blood port connector
IEC60601-2-52 Entrapment Test Tools | Cylinder Tool
IEC60601-2-52 Entrapment test tools | Cylinder tool Cylinder tool | IEC60601-2-52-Figure 201 .103 b Cylinder tool Key 1 Total weight 3,34 kg ±0,05 kg 2 Marked centre line 3 Surface roughness 1 ,6 4 Drilling hole for weight adjustment Figure 201 .1 03 b) – Cylinder tool schematic
Figure C.1 Female Reference Luer Lock Connector For Testing Male Luer Connectors Leakage
ISO 80369-7:2017 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications In Figure C.1, all outside edges of lug or thread form shall have a radius between 0,15 mm and 0,20 mm (unless otherwise specified). R may be × 45° chamfer. ISO 80369-7-Figure C.1 — Female reference luer lock connector for testing male luer connectors for leakage, separation from unscrewing, stress cracking and non
ISO 14457 Dentistry — Handpieces And Motors , ISO 14457 -Figure 3 Five Types Of Test Mandrel
ISO 14457 Dentistry — Handpieces and motors , ISO 14457 -Figure 3 Five types of test mandrel Test mandrel The test mandrel shall have the dimensions shown in Figure 3. The shape of the shank end for all types of test mandrels shall be either conical or rounded at the discretion of the manufacturer or test house to avoid damaging of the chuck system. The mandrel cylindricity shall not exceed a value of 2,5 µm and its hardness shall exhibit a value of at least 610 HV5. Test in
Cone Tool Medical Bed Standard Equipment
Cone tool | medical bed standard equipment It is designed according to the standard iec60601-2-52 figure 201.103a. It is made of aluminum and weighs 5.13 ± 0.05kg Model KP-61521 According to standard IEC 60601-2-52-Figure 201.103a Total weight 5.13 ± 0.05kg Surface roughness 1.6 Material Aluminum
IEC60601 Figure CC1 for Evaluate The Risk Degree Of V-Shaped Opening Of V-Shaped Opening Of Medical Devices
IEC60601 Figure CC1,Which Is Used To Evaluate The Risk Degree Of V-Shaped Opening Of V-Shaped Opening Of Medical Devices Triangle tool conforms to iec60601-2-52 figure CC. 1, which is used to evaluate the risk degree of V-shaped opening of medical devices. The tested area is V-shaped opening of B and C. the tool is made of aluminum and its mass is 3.34kg
Cylinder tool | IEC60601-2-52-Figure 201 .103 b Cylinder tool
Cylinder tool | IEC60601-2-52-Figure 201 .103 b Cylinder tool Key 1 Total weight 3,34 kg ±0,05 kg 2 Marked centre line 3 Surface roughness 1 ,6 4 Drilling hole for weight adjustment Figure 201 .1 03 b) – Cylinder tool schematic
ASTM F2554 22 Phantom Evaluating Tracking Accuracy Of A System
ASTM F2554 22 Phantom
IEC60601-1-Figure 33 Body Upper Carriage Module With Reservoir
Product Description IEC 60601-1-Figure 33 Body upper-carriage module 9.8.3.3 * Dynamic forces due to loading from persons Where dynamic forces (due to sitting down, standing up, PATIENT handling PROCESS or the like) can be exerted on ME equipment parts intended to support or suspend a PATIENT or OPERATOR in NORMAL USE, the ME EQUIPMENT shall maintain BASIC SAFETY and ESSENTIAL PERFORMANCE. Compliance is checked by the following test: Prior to performing this test, the PATIENT
IEC 60601-2-52 Standard Medical Bed Tester Featuring Sturdy Aluminum Loading Pad
Loading pad- Medical Bed tester Model KP-61523 According to standard IEC 60601-2-52-Figure 201.104 Total weight 1500N The equipment consists load pad + stainless steel drum + load steel ball Material Aluminum + stainless steel Size Φ335*500mm Standard drawing
IEC80601-2-60 Loading Fan Construction Aluminum Close Connection
IEC 80601-2-60 loading fan construction Standard: IEC80601-2-60-figure AA.4 Packaging and Shipping 1. Aluminium box and carton box, careful and tight package, make sure the package is intact. 2. The package will be shipped by DHL/Fedex/TNT/EMS/UPS/China post/EF-Express/Special line, as you have chose in the order. 3. The shipping time is different, it depends on the distance bewteen us. At usual, exclude the preparing time, the goods would be sent to you in 5days.
ISO 10079-1 Medical Suction Equipment , Part 1 Electrically Powered Suction Equipment
ISO10079-1:2015 Test Equipment List ISO10079-1:2015 Test Equipment List Clause Name Test Name Note 6.1.2&7.5.2 Container capacity: (ISO10079-1, Sub-Clause 6.1.2) &Overflow protection of electrical suction equipment: (ISO10079-1, Sub-Clause 7.5.2) 6.1.3 Container strength: (ISO10079-1, Sub-Clause 6.1.3) 6.3.1 Degree of collapse of Suction tubing: (ISO10079-1, Sub-Clause 6.3.1) Figure A.2 — Test apparatus for degree of collapse for suction tubing 7.5.3.1 Negative pressure
ISO / DIS 18193 2020-Figure A.3 Gauge Medical For Testing 6% Luer Conical Fittings
ISO/DIS 18193:2020- Cardiovascular implants and artificial organs — Cannulae for extracorporeal circulation ISO/DIS 18193:2020-Figure A.3 Gauges for testing 6% (Luer) conical fittings Packaging