SDB Plastic Materials Burning ISO5659 Nbs Smoke Chamber Smoke Density Chamber
SDB ISO5659 NBS Smoke Density Chamber Introduction: SDB ISO5659 NBS Smoke Density Chamber has proved to be one of the most versatile fire testing instruments since its inception in the 1980s. SDB ISO5659 NBS Smoke Density Chamber is the most widely accepted apparatus for the measurement of smoke from burning materials and measures specific optical density under flaming and non-flaming conditions. It is also used for the extraction of toxic gas. SDB ISO5659 NBS Smoke Density
IEC60134 Standard 27 Cubic Meter Cable Smoke Density Testing Equipment
IEC60134 Cable Smoke Density Testing Equipment Introduction: The 3MC IEC60134 Cable Smoke Density Testing Equipment is used for measuring the emission when the cable or optical cable is placed horizontally under the definite fire condition. 3MC IEC60134 Cable Smoke Density Testing Equipment comprises a cubic enclosure and a photo-metric system(the outer test chamber is not supplied by us, customers should build the room by themselves.) The specified standard fire source
SDB Solid Materials Flammability Test Equipment Smoke Optical Density Testing ASTM E662
SDB NBS Smoke Optical Density Testing Equipment Introduction: The SDB NBS Smoke Optical Density Testing Equipment has proved to be one of the most versatile fire testing instruments since its inception in the 1980s. SDB NBS Smoke Optical Density Testing Equipment is the most widely accepted apparatus for the measurement of smoke from burning materials and measures specific optical density under flaming and non-flaming conditions. It is also used for the extraction of toxic
UL94 Construction Materials Testing Equipment Plastic Materials Flammability Test
UL94-X Plastic Materials Flammability Tester Introduction: UL94-X Plastic Material Flammability Testing Equipment is widely applied throughout industry, especially in electrical manufacturing, where it is widely used for the testing of electrical products. UL94-X Plastic Material Flammability Testing Equipment measures the burning rate of samples positioned either horizontally or vertically. Flammability, combustion speed, flame spread, the intensity of combustion can be
Vertical Fire Testing Equipment , Horizontal Burning Flame Testing Equipment
UL94-X Horizontal Vertical Burning Flame Testing Equipment Introduction: The test is widely applied throughout industry, especially in electrical manufacturing, where it is widely used for the testing of electrical products. The test measures the burning rate of samples positioned either horizontally or vertically. Flammability, combustion speed, flame spread, the intensity of combustion can be acquired during test automatically and precisely; UL94-X Horizontal and Vertical
High Sensitivity IEC60695-11 Horizontal Vertical Flammability Tester
UL94-X IEC60695-11 Horizontal Vertical Flammability Tester Introduction: The test is widely applied throughout industry, especially in electrical manufacturing, where it is widely used for the testing of electrical products. The test measures the burning rate of samples positioned either horizontally or vertically. Flammability, combustion speed, flame spread, the intensity of combustion can be acquired during test automatically and precisely; UL94-X Horizontal and Vertical
CFRT IEC 60331 Electric Cable Fire Resistance Testing Equipment
IEC60331 Electric Cable Fire Resistance Testing Equipment -- Model CFRT Introduction: CFRT IEC60331 Electric Cable Fire Resistance Testing Equipment is used for testing cables required to maintain circuit integrity when subject to fire alone or fire with shock where the test condition is based upon flame with a controlled heat output corresponding to a temperature of at least 750˚C or fire with shock at a temperature of at least 830 °C. Reference Standards: IEC 60331 Test
CRA IEC60754-1,2 Electrical Cable Halogen Acid Tester
IEC60754-1, 2 Electrical Cable Halogen Acid Tester -- Model CRA Introduction: The International Electrotechnical Commission IEC 60754 Part 1 and Part 2 test is performed to determine the degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring the pH & conductivity. IEC 60754-1 is halogen-free cable came from and including the polymer to halogenated compounds on the basis of the additive compounds emitted during combustion,
BVC Bunched Cable Vertical Flame Tester
Bunched Cable Vertical Flame Tester -- Model BVC Introduction: Bunched Cable Vertical Flame Spread Tester is a series conforming to IEC 60332-3-10 (Category A~D) standards. The test measures the expansion of vertical flame to the electronically or optically vertical cable or wire using the standard ignition source while supplying a certain amount of air to a chamber of a defined volume. Additionally, if bunched cable vertical flame spread testers burner is adjusted by 20
SCV IEC60332-1-2 Single Cable Vertical Flame Tester
SCV IEC60332-1-2 Single Cable Vertical Flame Tester Introduction: Single Cable Vertical Flame Tester is used for the vertical flame propagation of a single insulated wire or cable is a bench scale test to determine the resistance of a single cable to a 1kW flame application. It conforms to IEC60332-1-2 (flame propagation) and IEC60332-1-3 (test for flaming droplets). Features: Stainless steel box, the height of 1300mm, width of 300mm, depth of 450mm. Two stainless steel rods,
3MC 27m3 Cable Smoke Density Tester
Electrical Cable Smoke Density Tester -- Model 3MC Introduction: The 3MC Smoke Density Tester is used for measuring the emission when the cable or optical cable is placed horizontally under the definite fire condition. The equipment comprises a cubic enclosure and a photo-metric system(the outer test chamber is not supplied by us, customers should build the room by themselves.) The specified standard fire source (ethanol 90±1%, methanol 4±1% and distilled water 6±1%) 1L±0.01L
SDB ISO5659-2 ASTM E662 NBS Smoke Density Chamber
NBS Smoke Density Chamber -- Model SDB Introduction: The Smoke Chamber has proved to be one of the most versatile fire testing instruments since its inception in the 1980s. It is the most widely accepted apparatus for the measurement of smoke from burning materials and measures specific optical density under flaming and non-flaming conditions. It is also used for the extraction of toxic gas. This equipment is satisfied with standards (ASTM E 662, BS6401, ISO 5659, NES 711,
UL94 Building Material UL94 Horizontal and Vertical Flame Chamber
Building Material Horizontal and Vertical Flame Chamber -- Model: UL94-X Introduction: The test is widely applied throughout industry, especially in electrical manufacturing, where it is widely used for the testing of electrical products. The test measures the burning rate of samples positioned either horizontally or vertically. Flammability, combustion speed, flame spread, the intensity of combustion can be acquired during test automatically and precisely; It conforms to all
LOI-A Automatic Type Limiting Oxygen Index Tester
Fully Automatic Type Limiting Oxygen Index Tester -- Model LOI-A Introduction: The oxygen index tester is designed to test combustibility by oxygen concentration, letting user know minimum oxygen concentration as necessary for combustion. The working principle is: Place the specimen into the testing chimney, filling with oxygen and nitrogen into the chimney, ignite the specimen, then measure the min concentration of oxygen to support continuous combustion. Standards: ASTM:
Economic Type Electrochemistry Method Oxygen Index Tester
Economic Type Electrochemistry Method Oxygen Index Tester -- Model LOI Introduction: OI Oxygen Index tester measures minimum oxygen concentration as necessary when specimen combustion. Oxygen sensor of this equipment is electro-chemistry type, which is precise and has less error rate. But it has short life and will be replaced each ten months. It meets the contents of standards like ASTM, ISO, NES and so on. Standards: ASTM: ASTM D2863 ISO: ISO 4589-2 NES: NES 714 Application