Domestic Gas Meters
G1.6 G2.5 G4 Domestic Diaphragm Ic Card Gas Meter Max Work Pressure 10 KPa
Product introduction IC (Diaphragm) Gas Meter:The diaphragm gas meter is used as the measurement base meter, and a new type of smart gas meter composed of a flow signal acquisition module, an IC card module, a valve control module, and a power management module is added. In addition to the volume metering functions of coal gas, natural gas, and LPG, the meter also has functions such as prepayment, electromechanical conversion of metering data, and valve control. Precise
Mechanical Diaphragm Flow Meter 2.5m3/H High Accuracy For Domestic House Gas
High Precision Mechanical Diaphragm Meters For Domestic House Gas Model number G1.6 G2.5 G4 Nominal flow q.n (m3/h) 1.6 2.5 4 Max flow q.max (m3/h) 2.5 4 6 Min flow q.min(m3/h) 0.016 0.025 0.04 Tolerance allowed 0.1qmax≤q≤qmax ±1.5% qmin≤q<0.1qmax ±3% Max work pressure pmax 0.5-50 kPa Pressure loss ≤180 Pa Lifetime Natural gas:10 years Artificial gas/LPG:6 years Max meter reading 99999.999 m3 Min meter reading 0.2 dm3 Deviation of electromechanical conversion <0.1m3 Working
Diaphragm Domestic Gas Meters G2.5 G4 High Safety ISO9001 certificate
Product introduction IC (Diaphragm) Gas Meter:The diaphragm gas meter is used as the measurement base meter, and a new type of smart gas meter composed of a flow signal acquisition module, an IC card module, a valve control module, and a power management module is added. In addition to the volume metering functions of coal gas, natural gas, and LPG, the meter also has functions such as prepayment, electromechanical conversion of metering data, and valve control. High Saftey
House G4 IP65 Wireless Meter Reader OHSAS18001 For Domestic
Remote Wireless Meter Reading I Cloud Control House Gas Meter IP65 Model number G1.6 G2.5 G4 Nominal flow q.n (m3/h) 1.6 2.5 4 Max flow q.max (m3/h) 2.5 4 6 Min flow q.min(m3/h) 0.016 0.025 0.04 Tolerance allowed 0.1qmax≤q≤qmax ±1.5% qmin≤q<0.1qmax ±3% Max work pressure pmax 10 kPa Pressure loss ≤250 Pa Lifetime Natural gas:10 years Artificial gas/LPG:6 years Max meter reading 99999.999 m3 Min meter reading 0.2 dm3 Deviation of electromechanical conversion <0.1m3 Working
Light Weight Domestic Gas Meters Accurate Reading Max Air Flow 4 m3
Light Weight Accurate Reading Civil Gas Meter Max Air Flow 4 m3 Model number G1.6 G2.5 Nominal flow q.n (m3/h) 1.6 2.5 Max flow q.max (m3/h) 2.5 4 Min flow q.min(m3/h) 0.016 0.025 Tolerance allowed 0.1qmax≤q≤qmax ±1.5% qmin≤q<0.1qmax ±3% Max work pressure pmax 0.5-50 kPa Pressure loss ≤180 Pa Lifetime Natural gas:10 years Artificial gas/LPG:6 years Max meter reading 99999.999 m3 Min meter reading 0.2 dm3 Deviation of electromechanical conversion <0.1m3 Working temperature -25
Mechanical Diaphragm Domestic Gas Meters IP65 Dustproof Waterproof Explosion Proof
IP65 Dustproof Waterproof Explosion-proof Civil Gas Meters Model number G1.6 G2.5 G4 Nominal flow q.n (m3/h) 1.6 2.5 4 Max flow q.max (m3/h) 2.5 4 6 Min flow q.min(m3/h) 0.016 0.025 0.04 Tolerance allowed 0.1qmax≤q≤qmax ±1.5% qmin≤q<0.1qmax ±3% Max work pressure pmax 10 kPa Pressure loss ≤180 Pa Lifetime Natural gas:10 years Artificial gas/LPG:6 years Max meter reading 99999.999 m3 Min meter reading 0.2 dm3 Deviation of electromechanical conversion <0.1m3 Working temperature
GPRS Automatic Reading Domestic Gas Meters Remote AMR AMI For Home
GPRS Automatic Reading Remote AMR AMI Home Gas Meters Model number G1.6 G2.5 G4 Nominal flow q.n (m3/h) 1.6 2.5 4 Max flow q.max (m3/h) 2.5 4 6 Min flow q.min(m3/h) 0.016 0.025 0.04 Tolerance allowed 0.1qmax≤q≤qmax ±1.5% qmin≤q<0.1qmax ±3% Max work pressure pmax 10 kPa Pressure loss ≤250 Pa Lifetime Natural gas:10 years Artificial gas/LPG:6 years Max meter reading 99999.999 m3 Min meter reading 0.2 dm3 Deviation of electromechanical conversion <0.1m3 Working temperature -25℃~
Ultrasonic Electronic Domestic Gas Meters 6m3/h with Accurate Sensor
Domestic Ultrasonic Electronic Modular Gas Meter with Accurate Sensor Model number G4 Nominal flow q.n (m3/h) 4 Max flow q.max (m3/h)6 6 Min flow q.min(m3/h) 0.016 Tolerance allowed 0.1qmax≤q≤qmax ±1.5% qmin≤q<0.1qmax ±3% Max work pressure pmax 10 kPa Pressure loss ≤250 Pa Lifetime Natural gas:10 years Artificial gas/LPG:6 years Max meter reading 99999.999 m3 Min meter reading 0.2 dm3 Deviation of electromechanical conversion <0.1m3 Working temperature -25℃~+55℃ Power source