Ophthalmology Equipment
2019 Auto Eye Test Vision Chart Projector / Ophthalmic Vision Tester
Features: Auto Chart Projector ACP-1800 1. Easy installation and maintenance: It is quite easy to replace light bulks, and unnecessary to adjust its focus and position. 2. Customer Programmable: Icons can be displayed in predefined sequence by programming. 3. Display Single Icon: Display single icon by multi-function mask plate. 4. Tilted Placement: Perfect image position can be obtained by adjusting the
Made in china 19" LCD vision chart DCP-200 convenient control Auto Chart Projector
Product Description Product Features for the LCD vision test chart 1) 2m to 4m adjustable use distance, which reduce operation room largely. 2) Inner projecting display, outside ray permitted; more accurately operating. 3) LCD remoter control, operating very visual and convenient 4) Even if to be kept at 2m distances, also realizes vision effect for projecting just like at 4m 5) The selection of charts has been specifically arranged to meet the needs of each market region. 6)
Professional Optical machine/ OCT with fundus camera function Optical Coherence Tomography
Product descriptions Name : OCT machine The OCT with fundus color photography with variable retina scanning modes and analysis procedures, which provides direct and reliable analysis reports for auxiliary examinations of retina diseases and glaucoma. High- definition and comprehensive High-definition OCT images with clear color fundus photography present a more accurate details in scanning area. OCT scanning for macula Fundus color photography Analysis for macula thickness 3D
hot selling factory price for the Children led vision test chart : E, C, Alphabet, Numbers
Children led vision test chart : E, C, Alphabet, Numbers What's new? 17 inch LED backlit screen New CNT test, which is more scientific, effective, and directive. CNT curve will be formed and displayed on the screen when the test is finished. Better user experience--- All tests icons are listed on home interface. Quick test list--- Pick ten or less frequently used tests to establish your own quick test list. V style optotype arrangement--- Avoid optotpyes congested on the
oct machine for eye clinic and hospital Optical Coherence Tomography
Product descriptions Name : Optical Coherence Tomography The OCT is a spectral domain OCT, the scan speed is 36000 A-scan/s. We use the same SLD light source as Carl Zeiss. For the fundus imaging, we are using the LSO technology, not the fundus camera. It's same as Carl Zeiss's High end device, such as Cirrus 4000 and Cirrus 5000. The frame rate is 10fps. It could provide the real time fundus image to the doctors. The field of view is 47 degree. Meanwhile, we have all basic
low price Ophthalmic Unit Optometry Combined Table
Product descriptions Ophthalmic Unit ptometry Combined Table Ophthalmic Chair Unit Feature: 1.luxurious design and graceful structure 2.Tabletop can rotate 90° 3.Small slidable table for refractor 4.Motorized Chair go up/down smoothly with low noise 5.Arm can swing to left/right to change position of phoropter 6.leg's protecting device specifications Unit size 1130*1100*1920mm Tabletop size 1000*480mm Table rotation angle 90° Arm swing range ±30° Chair up/down range 170mm
Factory price Chargeable Binocular Indirect Ophthalmoscope 25C
Product descriptions Characteristics 1. Imported LED lamp bulb has long service life . Even and bright illumination .The brightness can be adjusted continuously. 2. Clear image , perfect third dimension and broad view field. The engineering plastic is also applied in the instrument body with the exquisite and compact design. Super light weight, comfortable to operate . 3. Portable power supply , which is convenient for surgery , ward round and consultation , could provide 4
2019 NEWEST products ophthalmic surgical instruments Precise eye laser Photocoagulator
Features of Laser Photocoagulator Compact Compact and portable design for advanced solid-state-laser technology Touch-screen operations for easier use Precise Continuously zoomed and precise laser spot size Homogenous photocoagulation spot on retina Stable output but no power degeneration for closed-loop power control system Safe Minimized power density on cornea Maximum protection while
digital ophthalmic non contact tonometer
Introduction of Auto tonometer utilizes image control and feature recognition for auto 3-D positioning of xyz with reliable judgment and measurement results, and easy to operate. The air non-contact approach to measure IOP can also be used for corneal thickness Specification Intraocular pressure (IOP) measuring range 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg) Measuring system dual sensor system of light and pressure Working
ODM-2100S Low price stable quality Opthalmology Ultrasonic A/B Scanner with ISO, CE
ODM-2100S Ultrasonic A/B Scanner for Ophthalmology is specially designed for doctors those having a higher demanding with his diagnosis. From the fine image to the possibility of working with PC, each feature gives a feeling of profession. Besides these, you could also make two images the same time for comparing purposes. While working with computer, you may save images, video and diagnostic
Hot selling factory price for the Ophthalmic A/B Scanner SU-500AB with ISO, CE
SU-500AB A/B Scan with normal, vitreous body enhancement, retina observation mode, mainly used for diagnosis of intraocular diseases, display the location, shape range of the focus of infection and the relationship with the surrounding tissue. Can be diagnosed vitreous opacity, retinal detachment, eye base tumors etc. eye diseases. A scan is used to measure anterior chamber depth, lens thickness, axial length, calculate diopter of implant IOL as well. B scan: Frequency: 10MHz
CT-6 China Ophthalmic equipment Corneal Topography/Corneal topographer
CT-6 China Ophthalmic equipment Corneal Topography Clinical application in diagnosis of corneal astigmatism,quantitatively analysis the corneal shape and show the corneal diopter by data or different color such as axial curvature figure,corneal power figure,instantaneous curvature figure,and height graph.It can guide data of wearing corneal contact lens and improve the accuracy of contact lens adapter. Function * Placido Cone * Auto/Manual Measurement Mode * Display Multi
SW-6000 China Ophthalmic equipment Corneal Topography/Corneal Topographer
SW-6000 China Ophthalmic equipment Corneal Topography Corneal Topography SW-6000: By PLACIDO cone, 31 rings, a total of 7936 points. Through calculation and analysis, used in the clinical diagnosis of corneal astigmatism, quantitative analysis of corneal shape, display the corneal curvature by data or different colors, can display axial curvature map, tangential curvature map, height map, simulated corneal lens map and corneal 3D map. Can be used in preoperative examination
China Portable Binocular vision screener SW-800
Specification: Operation mode: Bino/Mono Optometry: Automatic DS:Range:-7.50D~+7.50D Resolution:0.25D/0.01D Accuracy:±0.50D DC:Range:0.00D~3.00D Resolution:0.25D/0.01D Accuracy:±0.50D Axis: Range:1°~180° Resolution:1° Accuracy:±5° Pupil size:Range :4.0 mm~9.0 mm Resolution :0.1mm Accuracy :±0.1 mm Pupil distance:Range :35 mm~80 mm Resolution:1mm Accuracy:±1 mm Gaze:0°~ 20° Measuring distance:1 m ± 5 cm Time per measurement: ~1s Fixation target: Light flash, attractive sound
China Portable monocular vision screener/vision screening Autosight 900
AutoSight 900 is a portable vision screening instrument used in all age groups. The working principle of the ray through the eye refraction refractive system focusing on the sensor, the signal processing through the eyes of the spherical, cylindrical diopter and axial refractive data. Technical parameter One key operation for test result One measurement detect multiple eye problems, including myopia, hyperopia, astigmatism, and anisometropia. Accurate results in less than 5
5.7" adjustable touch screen Optical Digital Auto Lensmeter with low price
5.7" adjustable touch screen Optical Digital Auto Lensmeter Description: This auot lensmeter is used for measuring single vision lenses, bifocal ( trifocal )lenses, progressive power lenses, ( PPL ) and contact lenses ( CL ). The display unit utillizes a full-graphic LCD, displaying measured values of right-eys and left-eye lenses at one time, and graphically showing the alignment condition in the shape of target. The menu is simple and clear. Icons are conveniently located
China high quality ophthalmic refraction chair unit at low price
Features: 1. Motor pressure up and down movement with lower noise; 2. Able to be equipped with arm, projector and so on; 3. Economical background illumination, comfortable; 4. Reasonable construction and clipper-built shape Specification: 1. Arm tilting angle…………±30º; 2. Table rotate angle……………90º; 3. Table slip scope………±150mm; 4. Chair rotate………………±60º; 5. Chair height…………500-700mm; 6. Weight………………200Kgs; 7.
Hot selling factory price for the SU50A Series Fundus Camera
50A Excellent Ophthalmic Series Fundus Camera Features: Patient can have a comfortable experience during the shooting program while using a chinrest which is designed in accordance with ergonomics. With excellent aspheric lens, a high efficient program of optical imaging is provided for operators. Split lines make the focusing operation much more convenient, and pupil alignment spots make the location much more accurate. Using a high resolution DSLR, we can provide you HD
korea technology auto refractometer Keratometer price with CE certificate SU-8600
korea technology auto refractometer Keratometer Patent for Focusing Control Algorithm When an operator miss focus of patient’ eyes during measurement, the system will make correction for right measurement data result. - It helps fast measurement with high accuracy - The software will help operators when they need to make measurement rapidly. Patent Temperature Compensation Circuit UNICOS’s new circuit detects temperature and compensates the temperature variation in measuremen
low price Auto Refractometer AR-800A
Product Description The AR-800A computerized optometer is an instrument that can quickly and accurately measure the diopter of eyes with a small 2.2mm pupil and a new LCD color screen design. The embedded microprocessing and fast image processing technology make the measurement speed faster. The diopter of small pupil can be measured quickly and accurately. New color screen design (5.7" true color TFT LCD). Automatic cloud and fog color visual beacon. Automatic pupil distance