Gas Sensor
CH2O/C-10 Formaldehyde Gas Sensor 3 Electrode Electrochemical Highly Sensitive CH2O Measurement
CH2O/C-10 Formaldehyde Gas Sensor 3 Electrode Electrochemical Highly Sensitive CH2O Measurement Applications • Continuous Air Quality Monitoring • Safety and Environmental Control Formaldehyde Gas Sensor CH2O/C-10 Cross Sensitivity Data The table below does not claim to be complete. Interfering gases should not be used for calibration. Please contact Membrapor AG for further support regarding cross sensitivities. Specification Sheet Rec. Load Resistor 10 - 33 Ω Bias (V_Sens-V
YJJ ZE14-O3 Electrochemical Ozone Module Is Used In Disinfection Cabinets Smart Home Equipment And Other Places
Product Description: ZE14-O3 Electrochemical Ozone Module Is Used In Disinfection Cabinets Smart Home Equipment And Other Places Features: ZE14-O3 electrochemical ozone module is a universal and miniaturized module. The detection of O3 in the air by electrochemical principle has good selectivity and stability. Built-in temperature sensor for temperature compensation; Digital output and analog voltage output at the same time, easy to use. ZE14-O3 is a universal gas module
YJJ ZE03-NH3 Electrochemical Module Is Used For Portable Stationary Gas Detectors
Product Description: ZE03 Electrochemical Module Is Used For Portable Stationary Gas Detectors Features: Electrochemical module ZE03 is a high-performance, universal electrochemical series module, it uses a three-electrode electrochemical gas sensor and high-performance microprocessor, equipped with different gas sensors can measure the corresponding gas. Built-in temperature sensor for temperature compensation, can accurately measure the gas concentration in the environment,
SGX-4CO Industrial Carbon Monoxide (CO) Sensor Electrochemical Gas Sensor Two-year Life Range 0 – 2000 ppm
SGX-4CO Industrial Carbon Monoxide (CO) Sensor OUTLINE: All dimensions are in mm All tolerances are ±0.15mm IMPORTANT NOTES: 1) Do not glue or solder to the connector pins as this may damage the sensor and thereby invalidate the warranty, please use PSB sockets. 2) Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website. 3) All performance specifications are based upon the following environmental
OX-B431 Electrochemical Gas Sensor Ozone Sensor And Nitrogen Dioxide Sensor O3 Sensor And NO2 Sensor Low Sensitivity To SO2 And Repeatable Sensitivity To NO2 Including Emissions Monitoring
OX-B431 O3 Sensor + NO2 Sensor Description Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ozone (O3) The new O3-B4 measures Ozone at low ppb concentrations. Low sensitivity to SO2 and repeatable sensitivity to NO2. OX-B431 O3 Sensor + NO2 Sensor Features High resolution up to 15ppb Short response time of 45s Linear output,
NO-A1 NO-AE Electrochemical Gas Sensor Nitric Oxide Sensor NO Sensor Industry Standard Size For Portable Gas Detectors Portable Safety Instruments Urban Air Monitoring And Stack Gas Analysers
NO-A1 Nitric Oxide Sensor (NO Sensor) Description Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology. NO-A1 Nitric Oxide Sensor size:20mm diameter, the industry standard size for portable gas detectors The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm.
NO2-BE NO2-B1 Electrochemical Gas Sensor Nitrogen Dioxide Sensor NO2 Sensor Best Choice For Fixed Site Applications Portable Safety Instruments Urban Air Monitoring And Stack Gas Analysers
Nitrogen Dioxide Sensor (NO2 Sensor) - NO2-B1 NO2-BE Alphasense Nitrogen Dioxide gas sensors operate using proven fuel cell technology. NO2-B1 Nitrogen Dioxide Sensor size:32mm diameter package, the best choice for fixed site applicationsThe NO2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 50 parts per billion (ppb) and an operating range to 20ppm. The
NO2-A1 Electrochemical Gas Sensor Nitrogen Dioxide Sensor NO2 Sensor Industry Standard Size For Portable Gas Detectors Urban Air Monitoring And Stack Gas Analysers
Nitrogen Dioxide Sensor (NO2 Sensor) - NO2-A1 Alphasense Nitrogen Dioxide gas sensors operate using proven fuel cell technology. NO2-A1 Nitrogen Dioxide Sensor size:20mm diameter, the industry standard size for portable gas detectorsThe NO2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 50 parts per billion (ppb) and an operating range to 20ppm. The sensors are
HCN 3E 30 F Electrochemical Gas Sensor Hydrogen Cyanide Very Stable Zero Reading Highly Sensitive For TLV-monitoring Leakage Detection Portable & Fixed Point Applications
Hydrogen Cyanide Sensoric HCN 3E 30 F FEATURES: Amperometric 3 electrode sensor cell Very stable zero reading Very selective Highly sensitive Fixed organic gel electrolyte TYPICAL APPLICATIONS: TLV-monitoring, leakage detection portable & fixed point applications Gold mining PART NUMBER INFORMATION: MINI 1639-231-30009 SENSORIC CLASSIC 1639-231-30069 CTL 4 series adaptation 1639-231-30049 CTL 7 series adaptation 1639-231-30079 Long Term Sensitivity Drift < 5% per month
5NO2-B43F NO2-B43F Nitrogen Dioxide Sensor 4-Electrode (High Humidity)
5NO2-B43F Nitrogen Dioxide Sensor 4-Electrode (High Humidity) LIFETIME: Zero drift ppb equivalent change/year in lab air 0 to 20 Sensitivity drift % change/year in lab air, monthly test -20 to -40 Operating life months until 50% original signal (24 month warranted) > 24 ENVIRONMENTAL: Sensitivity @ -20°C (% output @ -20°C/output @ 20°C) @ 2ppm NO2 60 to 80 Sensitivity @ 40°C (% output @ 40°C/output @ 20°C) @ 2ppm NO2 95 to 115 Zero @ -20°C nA 0 to 25 Zero @ 40°C nA -10 to 50
YJJ MG811 Electrolyte CO2 Sensor Is Used To Monitor CO2 Concentration In Air Quality Control Systems
Product Description: MG811 Electrolyte CO2 Sensor Is Used To Monitor CO2 Concentration In Air Quality Control Systems Features: MG811 electrolyte CO2 sensor is a semiconductor oxide chemical sensor that uses the principle of a solid electrolyte battery to detect CO2. When the sensor is kept at a certain operating temperature and placed in a CO2 atmosphere, electrode reaction occurs in the positive and negative electrodes of the battery, electromotive force is generated
NAP-57A N57A Catalytic Combustion Of Combustible Gas Sensor Probe It Can Be Used In Industrial And Commercial Flammable Gas Detectors And Has Good Detection Sensitivity In Toxic Gas Environments Such
NAP-57A N57A Catalytic Combustion Of Combustible Gas Sensor Probe It Can Be Used In Industrial And Commercial Flammable Gas Detectors And Has Good Detection Sensitivity In Toxic Gas Environments Such NAP 57 A is a newly developed catalytic type gas sensor based on conventional type NAP 56A for not only residential but also commercial or semi industrial application s because of having highly excellent poisoning resistivity S ince its power cons umption and pin position s are
MQ-6 MOS Flammable Gas Sensor For Methane CH4 LPG Detection Industrial Flammable Gas Alarm And Portable Gas Detector
MQ-6 MOS Flammable Gas Sensor For Methane CH4 LPG Detection Industrial Flammable Gas Alarm And Portable Gas Detector Profile: Sensitive material of MQ-6 gas sensor is SnO2,which with lower conductivity in clean air. When the target flammable gas exist, the sensor’s conductivity gets higher along with the gas concentration rising. Users can convert the change of conductivity to correspond output signal of gas concentration through a simple circuit. MQ-6 gas sensor has high
NAP-57A A Contact Combustion Type Combustible Gas Sensor Is Used For Stationary Alarms And Concentration Meters
Product Description: NAP-57A A Contact Combustion Type Combustible Gas Sensor Is Used For Stationary Alarms And Concentration Meters Features: NEMOTO Combustible Gas Sensor NAP-57A Nap-57a is a contact combustion type combustible gas sensor, the sensor has strong silicone resistance, in the fixed alarm and concentration meter and other fields has been selected by many customers. This kind of sensor itself does not have explosion-proof performance, it is recommended to put
H2S-B1 H2S-BH H2S-B4 Electrochemistry Hydrogen Sulfide Sensor Two-year Life High Current Output For Stationary Hydrogen Sulfide Transmitter
H2S-B1 H2S-BH H2S-B4 Electrochemistry Hydrogen Sulfide Sensor Two-year Life High Current Output For Stationary Hydrogen Sulfide Transmitter PERFORMANCE: Sensitivity nA/ppm in 20ppm H2S 300 to 440 Response time t90 (s) from zero to 20ppm H2S < 35 Zero current ppm equivalent in zero air < ± 0.2 Resolution RMS noise (ppm equivalent) < 0.1 Range ppm H2S limit of performance warranty 200 Linearity ppm error at full scale, linear at zero and 20ppm H2S 1 to -8 Overgas range maximum
EC4-Br2-5 3 Eletrode Electrochemical Gas Sensor Zero Bias High Sensitivity Excellent Sensitivity At Low Temperatures For Leakage Detection TLV-monitoring General Industry
EC4-Br2-5 3 Eletrode Electrochemical Gas Sensor Zero Bias High Sensitivity Excellent Sensitivity At Low Temperatures For Leakage Detection TLV-monitoring General Industry Features: • Zero Bias • High Sensitivity • High Selectivity • Excellent Sensitivity at Low Temperatures • Stable Zeropoint • Water Based Electrolyte • Double Sealed Housing for Advanced Leakage Protection Typical Applications: • Leakage Detection • TLV-monitoring • General Industry • Semiconductor Industry •
YJJ EC4-Br2-5 High Precision Electrochemical Bromine Gas Br2 Sensor
Product Description: EC4-Br2-5 High Precision Electrochemical Bromine Gas Br2 Sensor Features: • Zero Bias • High Sensitivity • High Selectivity • Excellent Sensitivity at Low Temperatures • Stable Zeropoint • Water Based Electrolyte • Double Sealed Housing for Advanced Leakage Protection Typical Applications • Leakage Detection • TLV-monitoring • General Industry • Semiconductor Industry • Emissions • Industrial Safety • Environmental Monitoring • Portable and Fixed Point
MG811 Electrolyte CO2 Sensor Is A Semiconductor Oxide Chemical Sensor That Uses The Principle Of A Solid Electrolyte Battery To Detect CO2
MG811 Electrolyte CO2 Sensor Is A Semiconductor Oxide Chemical Sensor That Uses The Principle Of A Solid Electrolyte Battery To Detect CO2 Product description: MG-811 is a semiconductor oxide chemical sensor that uses the principle of a solid electrolyte battery to detect CO2. When the sensor is kept at a certain operating temperature and placed in a CO2 atmosphere, electrode reaction occurs in the positive and negative electrodes of the battery, electromotive force is
7CO-100 051-1400-000 Gas CO Sensors 7 Series Electrochemical Carbon Monoxide
7CO-100 051-1400-000 Gas CO Sensors 7 Series Electrochemical Carbon Monoxide Product Description This sensor is designed for the measurement of Carbon Monoxide concentration in gas phase. It can be used as the pin-to-pin replacement of the standard 7-series electrochemical Carbon Monoxide sensors which made by the other manufacturers. Installation Output signals from the sensor pins are different. Inappropriate use of the pins in product design will affect the sensor
NH3-B1 Four Electrode Electrochemical Ammonia Sensor Electrochemical Gas Sensor For Detect The Concentration Of Ammonia In The Atmosphere Linear Current Output Easy Signal Processing
NH3-B1 Four Electrode Electrochemical Ammonia Sensor Electrochemical Gas Sensor For Detect The Concentration Of Ammonia In The Atmosphere Linear Current Output Easy Signal Processing NH3-B1 Ammonia Sensor NH3 Sensor Description Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ammonia (NH3) Our first family of Ammonia sensors. This