Triconex
Triconex CM3201 S2 Communication Module with 24 VDC Power Input and IP20 Ingress Protection
Environmental & Electrical Characteristics Power Input: 24 VDC (typical) Operating Temperature: -20°C to 60°C Storage Temperature: -40°C to 85°C Humidity Rating: 10% to 95% RH, non-condensing Ingress Protection: IP20 (typical) Installation & Environmental Guidelines Does the IP20 chassis rating limit our placement within the plant? Yes. The IP20 rating defines the CM3201 S2 as an "open-type" module. It is intended for installation within a secondary NEMA 4 or IP54/65
Triconex 3703E Isolated Analog Input Module with 16 Differential Input Points 12-bit Resolution
Parameter 3703E Voltage 0-5V or 0-10V, + 6% Type TMR, AI No. of Input Points 16, diff, isolated Isolated Points Yes Input Update Rate 50 ms Resolution 12 bits Accuracy < .15% of FSR (0° to 60°C) Input Resistance (load) 30 MΩ (DC), min. Power-Off Resistance 30 MΩ (DC), min. Common Mode Rejection -90 dB @ 60Hz, min. / -100 dB @ DC, min. Common Mode Range ±200V peak Leg-to-Leg Isolation 20 KΩ typical Normal Mode Rejection @ 8Hz: -3 dB / @ 60Hz: -17 dB / @ 120Hz: -23 dB Input
Triconex 4352B Communication Module with Fiber-Optic Connectivity
For installations using the TCM with fiber connectors (model 4352B), you will need to provide your own fiber-optic cables. The fiber cable you purchase should meet these specifications: Multimode 62.5/125 um cable Maximum length of 1.24 miles (2 kilometers) Compliance with ANSI/TIA/EIA-568-B.3 standards Every Tricon controller requires a Main Chassis and can support up to 14 Expansion or RXM Chassis. At least one ACM, NCM, EICM, or TCM module is necessary for TriStation PC
Triconex 4119A Communication Module with 4 Serial Ports, 500 VDC Port Isolation
The 4119A EICM enables seamless communication between your Tricon system and Modbus devices, TriStation, and printers. It supports multiple connection types including RS-232 for point-to-point communication with one master and one slave, or RS-485 for one master and up to 32 slaves. The RS-485 network operates on one or two twisted-pair wires with a range of up to 4,000 feet (1,200 meters). Each EICM features four serial ports and one parallel port, all capable of simultaneou
16 Bit Resolution AO3481 S2 Triconex Communication Module Safety Instrumented Systems
AO3481 S2 Triconex Communication Module Brand Triconex Product ID AO3481 S2 Packaging Original packaging Warranty period 1 year Delivery time 1-3 days Transportation period DHL /FEDEX /EMS /UPS /TNT Condition 100% original brand Payment method T/T The Triconex AO3481 S2 is a crucial communication module designed for the highly reliable and fault-tolerant Triconex Safety Instrumented Systems (SIS), such as the Tricon system. As part of a system engineered for critical safety