Temperature Transmitters
2 Wire Programmable Transmitter PR 5334B High Accuracy With Galvanic Isolation Programmable Sensor Error Value
2-wire programmable transmitter PR 5334B Product Overview TC input with high measurement accuracy Galvanic isolation for enhanced safety Programmable sensor error value Designed for DIN form B sensor head mounting Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree (enclosure/terminal) IP68 / IP00 Mechanical Specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g
High Measurement Accuracy Programmable Transmitter PR 5333D With 3 Wire Connection Programmable Sensor Error Value
2-Wire Programmable Transmitter PR 5333D RTD or Ohm input with high measurement accuracy 3-wire connection configuration Programmable sensor error value Designed for DIN form B sensor head mounting Environmental Conditions Operating temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degree (enclosure/terminal)IP68 / IP00 Mechanical Specifications DimensionsØ 44 x 20.2 mm Weight approx.50 g Wire size1 x 1.5 mm²
2 Wire Programmable RTD Transmitter 4-20ma PR 5332D For Precise Temperature Measurement
2-Wire Programmable RTD Transmitter PR 5332D Input Type: RTD or Ohm Accuracy: Better than 0.05% of selected range Features: Programmable sensor error value Mounting: For DIN form B sensor head Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree (enclosure/terminal) IP68 / IP00 Mechanical Specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g Wire size 1 x 1.5 mm²
PR 9113A Din Rail Temperature Transmitters With 4-20 MA Output
Temperature / mA Converter PR 9113A Product Overview Input for RTD, TC and mA signals Active/passive mA output via the same two terminals Available in 1 or 2 channel configurations Can be supplied separately or installed on power rail, PR type 94 Environmental Conditions Operating temperature-20°C to +60°C Storage temperature-20°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Installation inPollution degree 2 &
Field Mounted HART Temperature Transmitters PR 7501 With High Definition LOI Selectable Backlight
Field Mounted HART Temperature Transmitter Model: PR 7501 Product Overview RTD, TC, Ohm, and bipolar mV input with analog output High definition local operator interface (LOI) with 3 optical buttons Selectable red or white backlight display Environmental Conditions Operating temperature-40°C to +85°C (with silicone O-ring)-20°C to +85°C (with FKM O-ring) Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity0...100% RH (condensing) Protection
2-wire HART 7 Temperature Transmitters PR 6437A With RTD TC MV Inputs
PR 6437A 2-Wire HART 7 Temperature Transmitter Product Overview Advanced 2-wire HART 7 temperature transmitter supporting RTD, TC, potentiometer, linear resistance and bipolar mV inputs. Features single or true dual inputs with sensor redundancy and drift detection capabilities. Environmental Conditions Operating temperature -50°C to +85°C (standard) -40°C to +80°C (SIL) Storage temperature -50°C to +85°C Calibration temperature 23...25°C Relative humidity < 99% RH (non-cond.
PR 6337A Temperature Transmitters HART 7 Protocol For RTD TC Signals In DIN Rail Mounting
2-Wire HART Transmitter PR 6337A 1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals with 2 analogue inputs and 5 device variables with status available. HART protocol revision selectable. Environmental Conditions Operating temperature -40°C to +85°C Storage temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree IP20 Mechanical Specifications Dimensions (HxWxD) 109 x 23.5 x 104 mm Weight (1 / 2
HART 5 Protocol Temperature Transmitter PR 6335A 2 Wire With Galvanic Isolation
PR 6335A 2-wire HART Transmitter RTD, TC, Ohm, or mV input capability Extremely high measurement accuracy HART 5 protocol compatibility Galvanic isolation Available in 1- or 2-channel versions Environmental Conditions Operating temperature -40°C to +85°C Storage temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree IP20 Mechanical Specifications Dimensions (HxWxD) 109 x 23.5 x 104 mm Weight (1 / 2 channels)
High Accuracy Programmable Measurement Transmitter PR 6334A With Galvanic Isolation
PR 6334A 2-Wire Programmable Transmitter Product Overview TC input capability High measurement accuracy Galvanic isolation Programmable sensor error value Available in 1- or 2-channel versions Environmental Conditions Operating temperature-40°C to +85°C Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Mechanical Specifications Dimensions (HxWxD)109 x 23.5 x 104 mm Weight (1 / 2 channels)145 /
High Measurement Accuracy Programmable Transmitter PR 6333A With 3 Wire Connection
2-Wire Programmable Transmitter PR 6333A Product Overview RTD or Ohm input capability High measurement accuracy 3-wire connection system Programmable sensor error value Available in 1- or 2-channel versions Environmental Conditions Operating temperature-40°C to +85°C Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Mechanical Specifications Dimensions (HxWxD)109 x 23.5 x 104 mm Weight (1 / 2
Precise 2 Wire Programmable Transmitter PR 6331A Temperature Monitoring High Accuracy
PR 6331A 2-Wire Programmable Transmitter Key Features RTD, TC, Ohm, or mV input capability Extremely high measurement accuracy Galvanic isolation for enhanced safety Programmable sensor error value Available in 1- or 2-channel versions Environmental Conditions Operating temperature-40°C to +85°C Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Mechanical Specifications Dimensions (HxWxD)109 x
PROFIBUS PA Temperature Transmitters PR 5450A With PROFIBUS PA Profile 4.0 Multiple Input Options
PROFIBUS PA Temperature Transmitter Model PR 5450A Key Features PROFIBUS PA profile 4.0 compatibility Multiple input types: RTD, TC, potentiometer, linear resistance and bipolar mV Single or true dual inputs with sensor redundancy Drift detection capability Environmental Conditions Operating temperature -40°C to +80°C Storage temperature -50°C to +85°C Calibration temperature 23...25°C Relative humidity < 99% RH (non-condensing) Protection degree (enclosure/terminal) IP68 /
2 Wire HART 7 Temperature Transmitter PR 5437A With RTD TC Potentiometer Input IP65 / IP67
PR 5437A 2-Wire HART 7 Temperature Transmitter Key Features RTD, TC, potentiometer, linear resistance and bipolar mV input capability Single or true dual inputs with sensor redundancy and drift detection Wide ambient operating temperature range HART 7 protocol compatibility Environmental Conditions Operating temperature -50°C to +85°C (standard) -40°C to +80°C (SIL) Storage temperature -50°C to +85°C Calibration temperature 23...25°C Relative humidity < 99% RH (non-condensing
High Accuracy 2 Wire Level Transmitter PR 5343A With Programmable Sensor Error
2-wire Level Transmitter PR 5343A Key Features Potentiometer or Ohmic input Programmable sensor error value High measurement accuracy Unique process calibration function Programmable via standard PC Environmental Conditions Operating temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-cond.) Protection degree (encl./terminal)IP68 / IP00 Mechanical Specifications DimensionsØ 44 x 20.2 mm Weight approx.50 g Wire size1 x 1.5 mm² stranded
Industrial 2 Wire HART Pressure Measurement Transmitter PR 5337A With 4-20MA Output
2-wire Transmitter with HART Protocol PR 5337A Product Overview RTD, TC, Ohm, and bipolar mV input capability 2 analog inputs with 5 device variables and status monitoring Selectable HART protocol revision (HART 5 or HART 7) Environmental Conditions Operating temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degree (enclosure/terminal)IP68 / IP00 Mechanical Specifications DimensionsØ 44 x 20.2 mm Weight approx.50
HART 5 Protocol 2 Wire Temp Transmitters PR 5335A With Programmable Sensor Error Value
2-Wire Transmitter with HART Protocol - PR 5335A RTD, TC, Ohm, or mV input capability Extremely high measurement accuracy HART 5 protocol compatibility Programmable sensor error value Designed for DIN form B sensor head mounting Environmental Conditions Parameter Specification Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree (enclosure/terminal) IP68 / IP00 Mechanical Specifications Parameter
2 Wire Industrial Programmable Transmitter PR 5334A High Accuracy Galvanic Isolation TC Input
2-Wire Programmable Transmitter PR 5334A TC input with high measurement accuracy Galvanic isolation for enhanced safety Programmable sensor error value Designed for DIN form B sensor head mounting Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree (enclosure/terminal) IP68 / IP00 Mechanical Specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g Wire size 1 x 1.5 mm
2 Wire Programmable Transmitter PR 5333A High Accuracy 3 Wire Connection For RTD / Ohm Input
Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-cond.) Protection degree (encl./terminal) IP68 / IP00 Mechanical specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g Wire size 1 x 1.5 mm2 stranded wire Screw terminal torque 0.4 Nm Vibration IEC 60068-2-6 2...25 Hz ±1.6 mm 25...100 Hz ±4 g Common specifications Supply Supply voltage 8.0...35 VDC Internal power dissipation 25 mW…0.8 W
2 Wire Programmable RTD Transmitter PR5332A For Precise Temperature Measurement
Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-cond.) Protection degree (encl./terminal) IP68 / IP00 Mechanical specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g Wire size 1 x 1.5 mm2 stranded wire Screw terminal torque 0.4 Nm Common specifications Supply Supply voltage 7.2...35 VDC Internal power dissipation 25 mW…0.8 W Response time Response time (programmable) 1...60 s Voltage drop