LCD Pen Type Palm Digital Portable Hardness Tester For Steel

Price Negotiable
Price: USD200-500/Pcs
MOQ: 1
Delivery Time: 2-3 days upon advanced payment for small order
Brand: SADT
Product Description

HARTIP 1600 is an advanced state-of-the-art integrated palm sized metal hardness tester which incorporate impact device and controller into one unit. Using our patent technology, SADT HARTIP1600 gives out extraordinary high accuracy up to +/-2 HL. HARTIP 1600 will be used easily by menu operation even without operation manual, also it has a customer re-calibration and statistics function.

Advantages:
Integrated design , easy operation,

Digital with high contrast LCD display,

High accuracy with patient technology: +/-2 HL (or 0.3% @HL800),

Memories with 999 data, data can be recalled easily,

USB interface, it can connect to computer ,

Customer re-calibration allowed ,

Statistics value can be calculated automatically,

With strength conversion value
 

Accuracy
+/-0.3% @HL=800/+-2 HLD
Materials
10 common metal materials Steel/Cast Steel, Alloy tool steel, Stainless steel, Grey cast Iron , Nodular cast iron, Cast aluminum, Copper-Zinc Brass, Copper aluminium, Wrought cooper, Forged steel
Memory
999 data
Statistics function
Average/Max./Min.
Display
LCD with back light
Recalibration
Allowed by user
Impact device
D or DL
Indicator
Low battery
Materials
10 common metal materials Steel/cast steel, Alloy tool steel, Stainless Steel, Grey cast iron, Nodular cast iron, Cast aluminum, Copper-Zinc Brass, Copper aluminium, Wrought copper, Forged steel
Measuring range
HL170-960/HRC1-74/HRB1.2-140/HB8-1027/HV42-1220/HS3.9-112/HRA7-88.5/89-3300N/mm2
Working environment
-20C~+45C
Interface
USB for transferring data with PC
Net weight(g)
105
Power supply
AAA battery x1(1.2~1.5V)
Dimension(mm)
148x45x21
Standards
Conforming to ASTM A956, DIN50156, GB/T17394-199

 

Requirements related to sample weight

  • For samples weighing over 5 kg and of compact shape, no support is needed.
  • Samples weighing between 2-5 kg, and also for heavier samples with protruding parts or thin walls, should be placed on a solid support in such a manner that they do not bend or move by the impact force.
  • Samples weighing less than 2 kg should be firmly coupled with a stable support weighing over 5 kg.
  • For coupling purposes,
    • The coupling surface between the sample and base plate should be flat, plane parallel and ground.
    • A proper thin layer of coupling paste is to be applied to the contact surface of the sample.
    • The sample should be firmly pressed against the base plate surface by moving it with a circular motion.
    • The direction of impact should be perpendicular to the coupling surface.
  • For the coupling operation, the following prerequisites must be fulfilled:
    • Contact surface between the sample and the base plate must be flat, plane parallel and ground.
    • The direction of the test impact must be perpendicular to the coupled surface.
    • Minimum thickness of the sample for coupling under various impact devices are shown in following tab

Range for measurement and conversion:

 

IMPACT DEVICE D,DC L D : 200-900
  H R C H R B H B H V H S D
STEEL 20.0-67.9 59.6-99.5 80-647 80-940 32.5-99.5
CWT.ST 20.5-67.1     80-898  
ST.STEEL 19.6-62.4 46.5-101.7 85-655 85-802  
GC. IRON     93-334    
NC.IRON     131-387    
C.ALUM     30-159    
BRASS   13.5-95.3 40-173    
BRONZE     60-290    
COPPER     45-315    
 
_01_02

_04_05_06_07_08

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company SINO AGE DEVELOPMENT TECHNOLOGY, LTD.
Location Building 5, TEDA Raycom Park, No.12 Zhu Yuan Road, Tianzhu Free Trade Zone Shunyi, 101312, Beijing, China
Contact Person Hu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.