Silver Water Solenoid Valve 2S-400-40 / Stainless Steel Solenoid Valve Direct Drive

Price Negotiable
Price: negotiation
MOQ: 1 pc
Delivery Time: 3 days
Brand: BRANDO
Product Description

2S-400-40 Water Valve / Silver 1 1/2 Inch Stainless Steel Solenoid Valve Direct Drive

 

The two-position two-way water industrial valve uses high-quality copper core coils to enable the product to produce more stable magnetic properties and improve the stability of the switch.With 304 stainless steel valve body, it is strong and wear-resistant and does not rust.Thickened interface design for durability.

 

Specifiation

Model:2S-400-40

Voltage:AC220V AC110V  DC24V 

Body Material:304 Stainless Steel

Medium:Air,Water,Oil,Gas

Transfer method:Direct active

Type:Normal Close

Port Size:1 1/2″

Flow aperture:40mm

Oil seal material:NBR, EPDM

Pressure:0-0.7Mpa

Temperature:-5~80℃

 

Technical data

odel 2S025-06 2S025-08 2S040-10 2S160-10 2S160-15 2S200-20 2S250-25 2S350-35 2S400-40 2S500-50
CV value 0.23 0.23 0.6 4.8 4.8 7.6 12 24 29 48
Pipe size 1/8'' 1/4'' 3/8'' 3/8'' 1/2'' 3/4'' 1'' 1 1/4'' 1 1/2'' 2''

 

Drawing

Note:Don't install the water intake and outlet in contrast

 

Installation instructions

1. Special Note: The pipe must be cleaned and purged before installation to prevent impurities from clogging the valve port and destroying the sealing surface. If there are tiny impurities and dust, install a filter in front of the valve (filter ≥ 80 mesh cm2).

 

2. When installing, note that the arrow on the valve body should be consistent with the flow direction of the pipe, and the coil should be installed horizontally vertically.

 

3. Check whether the pressure, temperature and voltage are consistent with the actual parameters of the solenoid valve nameplate before installation.

 

4. Pay attention to the cleaning of the media. During the use, the components inside the valve should be cleaned regularly. After disassembly, the gasket should be inspected at the same time. If damage is found, it should be replaced in time.

 

5. When installing, clamp the valve body with a wrench, and then screw the pipe. Do not apply force to the coil to avoid bending and deformation of the solenoid valve and loosening of the connection.

 

6. After the solenoid valve is installed, it must be fluidly operated several times to ensure normal operation before it can be put into normal use.

 

Solenoid valve failure and elimination

Failure Reason Approach
Does not work after power on Poor contact of power supply wiring reconnect
The power supply voltage is not in the working range Adjust the normal position range
Coil break Resolder
Coil short circuit Replace the coil
Solenoid valve cannot be closed Seal damage Replace the seal
Fluid temperature is too high Replace the solenoid valve of the opposite port
Impurities enter the solenoid valve moving iron core Cleaning
Spring deformation Replace
Choke plugging Cleaning

 

please care the products details at our website, any confuse please contact us or Note your request online. Big quantity purchase ,please contact our online service to ask more economic shipping way or discuss the more pretty price.

 

Wait your inquiry!

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Ningbo Brando Hardware Co., Ltd
Location 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Contact Person Brandon Bao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.