48V DC 113-030-0045 113-030-0032 PU220 PU225 Solenoid Valve Bobine

Price Negotiable
Price: Negotiation
MOQ: 1000
Delivery Time: Negotiation
Brand: BRANDO
Product Description

48V DC 113-030-0045 113-030-0032 PU220 PU225 Solenoid Valve Bobine

 

Width: 30mm
Connection : FormA – EN 175301-803-A
Material : Duroplast
Voltage: 48V DC

 

Technical parameter of electronic drain valve solenoid coils:

Code No Voltage

Frequency

(Hz)

Power
W/VA
113-030-0042 24VDC   2,0  
113-030-0045 48VDC   2,1  
113-030-0032 48VDC   1,6  
113-030-0032 220VAC 50   6,4
113-030-0032 230VAC 50   6,6
113-030-0032 240VAC 50   5,7
113-030-0278 12VDC   6,0  
113-030-0026 24VDC   6,1  
113-030-0029 24VAC 50   10,8
113-030-0029 24VAC 60   9,6
113-030-0036 110VAC 50   11,1
113-030-0036 120VAC 60   11,7
113-030-0033 220VAC 50   10,8
113-030-0044 12VAC 50   19,3
113-030-0044 12VAC 50   17,1
113-030-0027 24VDC   11,0  
113-030-0039 24VAC 50   17,9
113-030-0039 24VAC 60   15,6
113-030-0037 110VAC 50   17,6
113-030-0037 120VAC 50   18,3
113-030-0034 220VAC 50   18,1
113-030-0034 240VAC 60   18,9
113-030-0033 240VAC 50   11,4
113-030-0047 12VDC   15,0  
113-030-0028 24VDC   15,0  
113-030-0040 24VAC 50   21,8,
113-030-0040 24VAC 50   19.4
113-030-0043 48VAC 50   26,2
113-030-0043 48VAC 50   23,2
113-030-0052 48VAC 50   19,0
113-030-0052 48VAC 50   16,6
113-030-0038 110VAC 50   24,8
113-030-0049 110VAC 50   21,7
113-030-0049 110VAC 50   19,2
113-030-0038 120VAC 50   26,1
113-030-0041 195VDC   16,6  
113-030-0035 220VAC 50   22,0
113-030-0050 230vAC 50   21,4
113-030-0050 230VAC 50   19,0
113-030-0031 240VAC 50   17,9
113-030-0035 240VAC 50   23,2


Main dimension of 5043/5045 solenoid coils for water electronic drain valve:

 

Detail enlargement of 14 mm Inside Hole 42 High electric solenoid coils:

 

Connection of AC220V/DC24V black electromagnetic coils in electronic drain valve:

 

In the process of using the electronic drain valve, the following points should be noted:


1. Before installing the drain valve, it is preferred to remove the sludge, copper scrap, rust, etc. from the compressed air system. It is recommended to drain the system for 3-5 minutes under full pressure before installing the drain valve.


2. The direction of drainage is the same as the direction of the arrow on the valve body.


3. The supply voltage should be consistent with the drain valve voltage (the drain valve voltage is marked on the coil). Do not connect the wrong power supply.


4. The test membrane switch on the timer is a manual test button. Each time the button is pressed, the drain valve is discharged once. This button is used to check the drainage condition at any time in daily work.


5. The two knobs of the timer are used to adjust the discharge and interval time. The user should adjust the time according to the climate and working conditions.


6. In addition to the connection function, the small screws on the drain valve junction box have the function of pressing the seal to prevent water from entering the timer and the coil, so be sure to tighten. Otherwise, the gasket will not be waterproof, which will cause the coil. And the burning of the timer. The lock nut of the terminal is also waterproof, so be sure to tighten.

 

7. When the electronic drain valve is in use, the solenoid valve may not be tightly closed, which is always leaking. Usually the fault is not caused by the quality of the drain valve itself. The reason is that the condensate is too dirty, and the tiny solid particles in it Enter the valve plug and catch the valve plug.

 

Welcome to your inquiry!

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.