16mm Hole Diameter AB510 DIN43650A Flow Control Valve Magnetic Coil

Price Negotiable
Price: Negotiation
MOQ: 500pcs
Delivery Time: Negotiation
Brand: BRANDO
Product Description

16mm Hole Diameter AB510 DIN43650A Flow Control Valve Magnetic Coil

 

The solenoid coil shown is AB510 solenoid coil which is used in CKD type AB31/41/42 solenoid valves. In addition, we have other AB310 and AB410 solenoid valve coils for you to choose.This AB510 is φ16mmx46mmx40mm; voltage is AC220V, DC24V; the power is AC:4.5VA, DC:31W; other voltgae and power can be customized; the connection type is DIN43650A; main material is thermoset, brass; Not only do we have the CKD type AB series solenoid coils, but we also have a matching armature assembly for you to choose.

 
 

Technical data of DIN43650A AB510 CKD Type Solenoid Valve Coil:

Model BB16039502
Normal voltage DC24V, AC220V, or customized
Normal power AC:4.5VA, DC:31Watt
Insulation class H
Connection type DIN43650A
Application CKD fluid control solenoid valves
Hole diameter 16mm
Height 40mm
Width 46mm

 

Main dimension of AB510 CKD Type Solenoid Coil For AB/AP Series Solenoid Valve:

 

Details display of AB510 CKD Type Electric Magnetic Coil φ16mm x 46mm x 40mm:

 

Production display of DC24V 220VAC AB510 CKD Type Electromagnetic Coil:

 

Other AB series (AB310, AB410) solenoid valve coils for your reference:

 

More display of AB510 CKD Type Solenoid Valve Coil in below Youtube Video:

 

Correctly repair the solenoid coil to reduce the occurrence of faults:

Any use of the product will cause certain faults, which is of course no exception for electromagnetic coils. The use of electromagnetic coils will bring great convenience to people, but if there is a fault, it will have a very bad impact on people, and people who pay attention to the maintenance of electromagnetic coils should pay attention.

 

1. It is necessary to test the voltage of the electromagnetic coil. When the attracting coil of the AC contactor has a voltage of 90% of the rated voltage of the electromagnetic coil, such an electromagnetic coil can work normally without worrying too much.

 

2. When using the electromagnetic coil, it is necessary to check whether there is overheating. If it is overheated, it will appear aging or discoloration. If this happens and it may be due to short circuit noise, it needs to be replaced at this time. To prevent accidents.

 

3. For the lead wire and the wiper wire of the electromagnetic coil, it is also necessary to check whether there is open welding or disconnection. If there is an abnormality, it must be repaired in time.

 

It is very important to correct the electromagnetic coil, which can reduce the occurrence of faults and avoid injury.

 

Focus on your demands, Offer you best solution:


√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Ningbo Brando Hardware Co., Ltd
Location 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Contact Person Brandon Bao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.