DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
                                                                                                           
Verified Supplier
22 Years
Since 2004
Menu

IEC 60331 Fire Retardant Testing Machine For Electric Cables

Price Negotiable
Price: Negotiation
MOQ: one set
Delivery Time: 15work days
Brand: DAXIAN
Product Description

IEC 60331, BS 6387 Electric Cables Under Fire Conditions Circuit integrity Testing Machine EN 50200

 

Description:

- Fire-resistant cable refers to the cable that can keep a safe running time in the case of flame combustion. Fire Resistance Tester is designed according to the requirements of IEC60331-11, and used to obtain the refractory characteristics of a fire resistant cable or optical cable under flame conditions.

- It is applicable to cables of rated voltage not exceeding 600V/ 1000V, including those of rated voltage below 80 V, matallic data and telecom cables and optical fibre cables.

- It is intended for use when testing cables of greater than 20mm overall diameter.
 

Standards:
- IEC 60331 

- BS 6387 

- EN 50200 

 

Main Features:
1. The burner is a belt type propane blowtorch with a Venturi mixer, and the burner nozzle is length 500mm, width 15mm;
2. Those burning holes are staggered into 3 rows, and the front width is 15mm, holes diameter is 1.32mm and these holes center distance is 2mm;
3.  One end of the specimen holder is equipped with a clamp to fix the sample, and the other end is convenient for heat transfer along the longitudinal specimen;

4. All fixtures are made of stainless steel;
5. The cable sample is supported by two metal rings, and the middle length of the two rings is about 300mm;
6. An inner diameter of the sample supporting metal rings is 150mm, and the cross-sectional diameter of the ring is 10 ± 2mm.
7. The position of the burner torch from burning the bottom is not less than 200mm, and not less than 300mm from the tank wall.


Combustion System:
1. Independent standard electrical control platform;
2. With intelligent detection function, when a short circuit in the sample during the test, automatic alarm and turn off the fire source.
3. Fuse current in the experimental circuit is 2A;
4. The sample is applied to power of AV 100V ~ 1000V adjustable;
5. The time can be set free for the fire, the time recommended by standards is 90min.


Device parameters:
 

The input voltage 0 ~ 1000V; can be adjusted
Maximum power 5000VA
Timer 0 ~ 999min
The flame temperature 0 ~ 1100 ºC adjustable
The test load current 0.25A, can be adjusted
The breakdown current 2A
Voltage AC 380V 3-phase, 50 / 60Hz, 30A

 


 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
Location No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China
Contact Person Sophia Su

Request A Quote

Please check your email address.
Your message must be at least 20 characters.