IEC 60529 IPX1-2 Vertical Drip Rain Test Chamber 600L For Household Appliances Waterproof Test
This equipment is primarily used to test the physical and related performance of electronic & electrical products, lighting fixtures, electrical cabinets, electrical components, automobiles, motorcycles and their spare parts under simulated dripping water climate conditions. After testing, product performance can be evaluated through inspection, facilitating product design optimization, improvement, calibration and factory inspection.
Application Fields
Lighting fixtures, household appliances, auto parts and other electronic & electrical products.
Compliant Standards
- IEC 60529:1989 + A1:1999 + A2:2013 - Degrees of protection provided by enclosures (IP Code), Clauses 14.2.1, 14.2.2 and Figure 3
- IEC 60598-1 - Luminaires - Part 1: General requirements and tests, Clause 9.2.3
Equipment Features
- Designed for IPX1 and IPX2 waterproof rating testing of products
- Double-layer structure with inner tank and outer cabinet; outer shell fabricated from high-quality A3 steel plate with baking paint coating
- All water-wetted components made of SUS304 stainless steel to prevent rust
- Vacuum-structured drip tank with patented brass cone technology for quick needle replacement
- Water supply pipeline equipped with precision filter to remove impurities and prevent needle clogging
- Compressed air drainage function to prevent scale buildup and needle blockage
- Sample carrier driven by stepper motor with precise rotation speed and angle settings via touch screen
- 50 mm cable port with rubber plug for external power supply to test samples
- Built-in LED waterproof lamp with tempered glass observation window
- Internal circulating water tank with automatic water level control and alarm detection
- Core control unit with 7-inch touch screen and imported electrical components
- Self-developed UI operation interface for simplified IP rating testing
- Four casters for easy movement and positioning
- Built-in spare parts storage box for accessories
Technical Parameters
| Technical Parameters | Structural Parameters |
|---|---|
| Drip Plate Size | Approx. L600 × W600 mm |
| Inner Chamber Size | Approx. L800 × D800 × H1000 mm |
| Overall External Dimension | Approx. L1250 × D1020 × H1750 mm |
| Drip Hole Diameter | Ø0.4 mm |
| Spacing Between Drip Holes | 20 × 20 mm |
| Turntable Diameter | Ø600 mm |
Functional Parameters
| Rainfall Volume | IPX1: 1±0.5 mm/min IPX2: 3±0.5 mm/min |
| Flow Regulation Mode | Manual adjustment |
| Drip Plate Lifting Mode | Fixed non-liftable type; lifting realized by sample carrier turntable |
| Turntable Lifting Height | 400-700 mm |
| Turntable Load Capacity | 50KG |
| Turntable Tilt Angle | 0° or 15° (horizontal reference) |
| Turntable Rotation Speed | 1 r/min (for IPX1 test) |
| Test Time Range | 0-999 min |
| Safety Protection Devices | Earth leakage protection, water shortage protection, short-circuit protection |
Electrical Parameters
| Power Supply | AC 220V |
| Rated Power | 1.0 kW |
Standard Accessories
1 copy of operation manual, 1 copy of factory certificate, 1 equipment warranty card, 1 filter cartridge, 100 test drip needles, 20 brass drip needle bases
Operating Conditions
The user shall guarantee the following conditions and complete corresponding connections.
Installation Site
- Flat floor with smooth drainage; floors and walls shall be waterproofed, equipped with floor drains or drainage ditches
- Floor load capacity ≥ 200 kg/m²
- Well ventilated site
- No severe vibration around the equipment
- No strong electromagnetic field interference around the equipment
- No flammable, explosive, corrosive substances or dust near the equipment
- Adequate space for operation and maintenance: 600 mm clearance at rear, left, right and top sides; 1200 mm clearance at front side
Ambient Conditions
- Temperature: 5°C ~ 35°C
- Relative Humidity: ≤85% RH
- Atmospheric Pressure: 86 kPa ~ 106 kPa
Power Supply Conditions
- Voltage & Frequency: AC 220V±10%, 50Hz±10%; Live wire + Neutral wire + Protective Earth wire
- Installed Power: 1.0 kW
- Protective Earth Resistance: Less than 4 Ω
- Power Switch: User shall install an independent residual current circuit breaker (RCCB) of matching capacity exclusively for this equipment
Water Supply Requirements
User shall provide water supply with water pressure ≥0.2 MPa, fitted with a 4-point water tap within 2 meters from the equipment.
Air Supply Requirements
Air compressor is required; recommended air pressure: 0.6 ~ 0.8 MPa.


Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Sinuo Testing Equipment Co. , Limited
Location
Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Contact Person
Zoe Zou