VFD500-PV Solar Pump Inverter Technical Specifications
Electrical Specifications
| Parameter | 220V Model | 380V Model |
|---|---|---|
| Max Input DC Voltage | 450V | 810V |
| DC Voltage Range | 150-450VDC | 300-810VDC |
| Normal Working DC Voltage | 260-400V | 400-650V |
| Recommended MPPT Voltage | 330V | 550V |
| MPPT Efficiency | >99% | |
| Rated Output Voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
| Output Frequency Range | 50/60Hz | |
| Maximum Efficiency | 99% | |
| Power Range | 0.75kW to 75kW | 1.5kW to 160kW |
| Cooling Method | Air Cooling | |
| Protection Degree | IP20/IP65 | |
| Altitude Rating | Below 1000m; above 1% for every additional 100m | |
| Certifications | CE/ROHS | |
Installation Recommendations: Solar panel power should be 1.3-1.4 times higher than solar pump power. Solar pump inverter power should be higher level than solar pump. For distances exceeding 100m between solar pump and inverter, install output reactor or use higher power inverter. Solar panel total VOC must be less than maximum DC voltage of inverter.
Key Features & Advantages
- Automatic Operation: No parameter setup required - runs automatically after wiring connection
- Dual Power Support: Simultaneous solar panel and AC power operation with automatic compensation
- User-Friendly Interface: Easy parameter access and monitoring via LCD keypad
- Advanced Protection: Sleep/wake functions, dry run protection, self-learning, and water full protection
- High Efficiency: MPPT efficiency tracking exceeding 99% with PID function support
- Remote Monitoring: 2G/3G/4G GPRS remote monitoring capability
Operation & Setup Guide
- Motor Parameter Setup: Configure P11.02-P11.06 parameters according to motor pump nameplate specifications
- Dry Run Protection: Measure unload protection current if required, otherwise proceed to next step
- Solar Pump Optimization: Set additional solar pump parameters for optimal performance
- Troubleshooting: If motor pump fails to output water above 40Hz, disconnect power and replace any two-phase motor wiring