IEC60112 CTI And PTI Flammability Testing Equipment PLC Control

 

Standard:

IEC60112-2009 Method for the determination of the proof and the comparative tracking indices of solid insulating materials.

It specifies the method of test for the determination of the proof and comparative tracking indices of solid insulating materials on pieces taken from parts of equipment and on plaques of material using alternating voltages. Flammability Testing Equipment

 

comparative tracking index

CTI

numerical value of the maximum voltage at which five test specimens withstand the test period for 50 drops without tracking failure and without a persistent flame occurring and including also a statement relating to the behaviour of the material when tested using 100 drops

 

proof tracking index

PTI

numerical value of the proof voltage in volts at which five test specimens withstand the test period for 50 drops without tracking failure and without a persistent flame occurring

 

Parameter:

ParametersModel LT-3(0.5m³) (Touch screen)
Working voltage 220V/50Hz, 1KVA
Control operation mode PLC control, 7 inch color touch screen operation, with infrared remote control
Testing voltage 0~600V adjustable, precision 1.5%
Timing device 9999X0.1S
Electrode Material: Platinum electrode and brass connecting rod
Size: (5±0.1)×(2±0.1)×(≥12)mm, 30°slant, Tip rounding:R0.1mm
Relative position of electrode Included angle: 60°±5°, distance is 4±0.1mm
Electrode pressure 1.00N±0.05N, Touch screen display
Dripping liquid The interval time of dropping liquid: 30±5S, digital display, can be preset
Height: 35±5mm
The number of drips:0-9999 times, can be preset, the volume size of the dripping liquid is controlled by the imported micro pump within 50 ~ 45 drips /cm³
Test liquid resistance A liquid 0.1%NH4Cl, 3.95±0.05Ωm, B liquid 1.7±0.05Ωm
Time-delay circuit 2±0.1S (in 0.5A or larger current)
Short-circuit pressure drop 1±0.1A 1%, pressure drop 8% MAX
Wind speed 0.2m/s. Flammability Testing Equipment
Environmental requirement 0~40℃, relative humidity≤80%, in the place of no obvious vibration and corrosive gas
Dimensions and weight WDH=1100×550×1200 mm, about 130kg

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Location No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
Contact Person Tessa Huang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.