Low Insertion LSZH 1.8mm Fiber Optic Patch Cord LC To LC
Low Insertion Single-Mode Simplex 1.8mm Fiber Optic Cable LC To LC Connector
Basic Introduction:
LC Apc fiber patch cord has good in repeatability and exchangeability and 100% Insertion, Return Loss, End Face, and Interference inspection.
Optical fiber is sensitive to stress, particularly bending stress. When overstressed, light in the outer part of the core is no longer guided in the fiber are core creating a higher loss at the stressed section of the fiber. Geehe's bend insensitive fiber patch cords (BIFPC) are constructed with Corning, by preventing as much bending loss as possible.
The cords are available with LC connectors in a variety of polishes and standard lengths of up to 30 meters.
Fiber Optic Patch Cord Benefit & Features:
- Bend insensitive OM2, OM3, OM4, and OS2 type fibers
- Conforms to IEC, EIA-TIA, and Telecordia performance requirements
- Available in duplex configurations with clips
- Low insertion loss
- High return loss &high reliability& stability
- Standard LC ,SC ,FC,ST, MU,MPO connector types
- TIA color-coded connectors
- Riser Rated (OFNR) jacket type
- Precision ferrule end-face geometry
- Factory polished tested and serialized
Fiber Optic Patch Cord Applications:
Use to carry signals in LANs, SANs and high-speed parallel interconnects for head-ends, central offices, and data centers
Use with vertical-cavity surface-emitting laser (VCSEL) or LED laser light sources in a LAN network
Add backward and forward compatibility to a high-speed data network
Specification&Technology Parameter
| Parameters | Value | ||||
| Connector Type | LC/UPC,LC/UPC | ||||
| Center Wavelength(nm) | 1310 or 1550 | ||||
| Max.Insertion Loss(dB) | 0.3 | ||||
| Min.Extinction Ratio(dB) | 23 | ||||
| Min.Return Loss(UPC) (dB) | 50 | ||||
| Min.Return Loss(APC) (dB) | 60 | ||||
| Key Orientation | Slow Axis | ||||
| Axis Alignment(deg) | ±3 | ||||
| Operating Temperature(℃) | -20~+70 | ||||
| Storage Temperature(℃) | -40~+85 | ||||
| FIber Type | PM Panda Fiber | ||||
* For Device with connector.IL is 0.3dB higher,RL is 5dB lower,ER is 2dB lower.
* The default connector key is aligned to the slow axis.
LC Connector Specification& Technology Parameter:
| Parameter | Unit | Index | |||
| End-Face Type | PC | UPC | APC | ||
| IL | dB | SM: ≤0.3;MM ≤0.1 | |||
| Repeatability | dB | ≤0.1 | |||
| interchangeability | dB | ≤0.2 | |||
| RL | SM | dB | ≥50 | ≥50 | ≥50 |
| MM | dB | ≥36(Without APC connector) | |||
| Mating Times | >1000 | ||||
| Operating Temperature | ℃ | -40~ +80 | |||
LC Patch Cord Ordering Information:
| OFC | -X | -XX | -XX | -XX | -X | -X |
| S: Simplex D: Duplex |
LA:LC/APC LC:LC/UPC LP:LC/PC | LA:LC/APC LC:LC:UPC LP:LC/PC | 09:0.9mm 20:2.0mm 30:3.0mm | 0:G652D 1:G657A 2:50/125 3:62.5/125 4:others | 0.5:0.5m 1.0:1.5m 10:10.0m |
|
| Fiber Mode | Connector Type | Connector Type | Cable Diameter | Flange Type | Fiber Length |
* EX:OFC-D-LA-LA-09-1-1.0
You decide:
- Fiber types (G652-D, G657A1, G657A2, ULTRA, G655, OM1, OM2, OM3, and OM4), also available in various types of cable.
- Connector types (conform IEC 61753, 61754, 61755) such as SC/APC 8 degrees, LC/APC 8 degrees, E2000/APC 8 degrees, SC/PC, LC/PC, ST/PC, MTP, and LC Uniboot.
- The required quality (A-, B-, C-, or D-grade).
- Any length and color you need.
- 100% ceramic ferrule (standard for prime quality guarantee) or other ferrule types (on request)