IU22 Ultrasonic Machine Repair No Display Failure
Price:
Negotiable
MOQ:
Negotiable
Delivery Time:
2-4 working days
Product Description
IU22 Ultrasound Device Has No Display
Fault phenomenon
After pressing the power button, the screen of the IU22 ultrasound device does not display an image.
Fault analysis and Troubleshooting
The device's non-display failure is roughly divided into two categories: the display or the display cable is faulty; the computer host fails to start normally. After the device is turned on, you can feel the vibration of the host when it is running. Press the shutdown button to shut down normally and judge the host computer to be normal. The fault may be a fault in the monitor or the monitor power cord.
Remove the device monitor, connect a computer monitor with DVI interface, the image display is normal, and finally determine the monitor failure. Disassemble the monitor, detect that the high-voltage board of the monitor is burnt out, and the front-level power supply of the driver board burns through, and the equipment is used normally after maintenance.
Summary
The failure of the display can be easily detected by the replacement method. It should be noted that the resolution of the current computer display is relatively high, the hardware of the ultrasound device does not support it, and a compatibility error will be reported after booting. When replacing, you can connect the original monitor to boot, unplug the video cable and connect to the new monitor.
Ultrasound parts that we can repair:
| Repair List of Featured Ultrasonic Board & Assy | |||
| Brand | System | Description | Part Number |
| GE | Logiq P5 | CPU mainboard | 5168431 |
| GE | Logiq P6 | CPU mainboard | |
| GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
| GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
| GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
| GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
| GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
| GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
| Aloka | Alpha 5 | mainboard | EP493700DD |
| Aloka | Alpha 6 | RX Beam Former | EP555501AA |
| Aloka | Alpha 6 | CW board | EP555700 |
| Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
| Aloka | Alpha 6 | TX/RX | EP555300 |
| Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
| Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
| Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
| Hitachi | F37 | TX/RS | EP557400/EP557300 |
| Hitachi | F37 | mainboard | EP575700BC/EP560800 |
| Aloka | F75 | USP board | EP556600 |
| Aloka | F75 | Cell Board | EP558800 |
| Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
| Hitachi | Arietta 60 | CELL | EU-9160C |
| Hitachi | Arietta 70 | TX | EP572300AA |
| Hitachi | Arietta 70 | CELL | |
| Hitachi | Noblus | CELL | |
| Hitachi | Noblus | CONT-B | |
| Hitachi | Ascendus | CELL | 7352830A |
| Siemens | X150/G40 | BE | 10131804 |
| Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
| Siemens | X700 | BE | 10136465 |
| Siemens | X700 | RC | 10136467 |
| Siemens | X700 | TI | 11014292 |
| Siemens | Antares | BE | 7472421 |
| Siemens | Antares | CB | 7288504 |
| Siemens | S2000 | RM300 | 10852163 |
| Siemens | S2000 high version/S3000 | RM301 | 10854749 |
| iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
| iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
| HD15 | ACB acquisition control board | 453561197145/453561197144 | |
| HD15 | AIM board | 4.53561E+11 | |
| CX50 | control panel | 4.53562E+11 | |
| CX50 | mainboard | 453561368033/453561622163/453561495832 | |
| Affiniti 70 | ACQ acquisition control board | ||
| EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
| Esaote | Mylab Series | CPU mainboard | 9501361000 |
| Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
| Toshiba | Aplio 500 | RX | ywm2056*a |
| Toshiba | Xario 200 | TX | PM30-32732-1 |
| Toshiba | Xario 200 | RX | PM30-32733-1 |
| Remarks | |||
| 1.The repair cycle is within 3-5 days. | |||
| 2.Warranty after fixed:60 days. | |||
| 3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
| 4.Package price is available if repair 3 pcs or more at one time. | |||
| 5.Extra discount for VIP partners. | |||
| 6.You could have different part No.under same description. | |||
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Guangzhou Rongtao Medical Tech LTD.
Location
Room 201, 203, Building C ,No. 26, Ningcai Road, Huangpu District, Guangzhou, China
Contact Person
Aurora Zhu