Ultrasound Machine Repair
Bisound Biosound Mainboard Processor Board 9501080 9501361000
Repair Bisound MyLab 15/25/30/40/50 mainboard 9501361000 1. Part number: 9501361000/9501361/ 9501080 2. Compatible with Bisound MyLab 15/25/30/40/50 Ultrasound 3. With 60 days warranty 4. Maintenance time: 2-4 days Knowledge point The BioSound Biosound MyLab 25 provides excellent image quality with sophisticated software and features. In combination with the high-level of performance in general imaging, the BioSound MyLab 25 covers and satisfies all clinical needs for a shared
5245004 5244555 Ultrasound Machine Repair Ge Logiq P6 PST Power Supply
Repair Troubleshoot GE LOGIQ P6 APS II PST DC POWER SUPPLY (P/N:5244555) 1. Part number: 5245004/5244555 2. Compatible with GE Logiq P6 3. With 60 days warranty after fixed 4. Maintenance time: 2-4 days Knowledge Point GE Logiq P5 Features The GE LOGIQ P5 ultrasound system puts quality ultrasound technology well within the reach of your private practice, a specialized clinic, or a hospital. It offers solid image quality, including enhanced 4D capabilities and an extensive
5168431 CPU Board Diagnostic Medical Device With GE Logiq P5
Maintenance GE Logiq P5 Ultrasonic CPU Board( P/N: 5168431) 1. Part number: 5168431 2. Compatible with GE Logiq P5 3. Maintenance cycle: 2-4 days 4. Warranty: 60 days after fixed Logiq P5 Compatible Ultrasound Probes / Transducers GE 3.5C Curved Array Probe GE 4C Curved Array Probe GE 5C Curved Array Probe GE 8C Curved Array Probe GE E8C Endocavitary Probe GE 9L Linear Array Probe GE 10L Linear Array Probe GE 12L Linear Array Probe GE 3S Sector Array Probe GE 5S Sector Array
GE 5396937 2 Medical Ultrasound Machine Repair Voluson S6 S8 P8
Repair GE Voluson S6/S8/P8 BF64 board 5396937-2 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 5396937-2 4. Compatible with GE Voluson S6/S8/P8 Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC 2158390-2 GE Logiq 400 VIPP 2245652 GE Logiq 400 MPU ASSY (CPUboard) 2123339 GE Logiq 400 LV3 power board 2211491
GE RFS Board Ultrasound Machine Repair 5364098-2 5364098-3
Repair Voluson S6/S8/P8 CPS ASSY Power Supply (P/N:5393431) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 5393431 4 .Compatible with GE Voluson S6/S8/P8 Knowledge Point GE Voluson S10 The GE Voluson S10 is a high-end and full-featured ultrasound system designed for general radiography use and specialized for OB/GYN with particular features for realtime 3D/4D acquisition. The GE Voluson S10 is developed based on Voluson S series platform; however, it has
SONOACE X6 Ultrasound Machine Repair For Hospital
Maintenance Cases of MEDISON SONOACE X6 Color Doppler Ultrasound The fault phenomenon The color Doppler machine of SONOACE X6 operates normally, but there is no display in the image area after entering the working interface of the ultrasound. Failure analysis Remove the SONOACE X6 probe interface board and observe that the internal structure of the machine consists of only three plates, namely FE plate, BE plate and POWER plate. Since the probe has normal working sound after
5177848 3 Ultrasound Machine Repair SYSCONPM Board GE Logiq P5
Repair GE Logiq P5 SYSCONPM Board 5177848-3 1. Part number: 5177848-3 2. Compatible with GE Logiq P5 3. With 60 days warranty after fixed 4. Maintenance time: 2-4 days Note: Different faults are also able to be fixed. Knowledge point The GE Logiq P5 ultrasound system provides high end imaging capability in a mid range affordable system. A full range of broadband transducers including 4D options make the P5 a perfect fit for a private practice office setting. Enhanced 4D
Aloka Alpha 7 Ultrasound Machine Repair EP539100BB For Image Fault
Aloka Alpha 7 RX board Diagnosis Model: Aloka Alpha 7 Part number: EP539100BB, EP539501DG, EP539500DE Failure phenomenons: Few lightspots occurred on the image Solutions: Diagnose from EP539100BB, EP539501DG, EP539500DE Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8 RSR KTI301394-2
Aloka EP555501AA Beamformer Ultrasound Spare Parts
Repair Aloka Alpha 6 RX Beamformer EP555501AA/Radiography 1. Part Number: EP555501AA,EP555501,EP5555/555501 2. Condition: Original and used,in good working condition 2. Repair Time: 2-4 days 3. Warranty :60 days Knowledge point The Aloka ProSound Alpha 6 is small, fast and powerful, which makes it an ideal choice for virtually any office setting. It provides advanced options like 3D/4D imaging, Color Flow 3D, Multi Slice Imaging (MSI) and 3D Automated Volume Measurement in a
GE Voluson E6 Ultrasonic System Repair
GE Voluson E6 System Reports Error The parts with high failure rate&available in stock of this machine: 1.RSX(KTZ303054/KTI303054) 2.RST(KTI301148) 3.RSR(KTI301394-2/KTI196357) 4.RFM201 FE mainboard(KTZ303916) 5.RFM221 FE mainboard(KTZ303915) 6.RFM423 FE-Mainboard(KTZ304074/5729200) 7.RFI20/ RFI21b Board(KTI300614/KTI302197_6) Common faults of GE ultrasound machine System Faults Solutions LOGIQ 500 No image when scanning far field Check power supply, reinsert the circuit
Repair GE GFS Main Board Assy 5371196 2 / 5455247
Repair GE Logiq S8 mainboard GFS Assy (P/N: 5371196-2/5455247) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 5371196-2/ 5455247 Note: Different faults are also able to be fixed. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC 2158390-2 GE Logiq 400 VIPP 2245652 GE Logiq 400 MPU ASSY (CPUboard) 2123339
Aloka Alpha 6 Ultrasound Machine Repair STCW Assy EP555700 CW Board
Repair Aloka Alpha 6 STCW Assy 1. Part Number: EP555700BD 2. Repair time: 2-4 days 3. With 60 days warranty Knowledge point The Aloka ProSound Alpha 6 is small, fast and powerful, which makes it an ideal choice for virtually any office setting. It provides advanced options like 3D/4D imaging, Color Flow 3D, Multi Slice Imaging (MSI) and 3D Automated Volume Measurement in a system with the smallest footprint in its class. This model also provides exceptional efficiency when it
GE VIVID Ultrasound Machine Repair For System Maintain 60 Days Warranty
GE VIVID I System Maintainance First, the failure phenomenon: The machine starts normally, and after receiving the probe, it prompts an error and the probe is not recognized. Second, the failure analysis: The ultrasonic probe does not recognize the power supply that normally considers the probe interface board or supplies power to the probe interface board. The machine configuration diagram shows that there is no high-voltage switch on the interface board of the model, that
Ultrasound Repair Service Ge Logiq P6 Pst Power Supply 5245004 / 5244555
Repair Troubleshoot GE LOGIQ P6 APS II PST DC POWER SUPPLY (P/N:5244555) 1. Part number: 5245004/5244555 2. Compatible with GE Logiq P6 3. With 60 days warranty after fixed 4. Maintenance time: 2-4 days Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC 2158390-2 GE Logiq 400 VIPP 2245652 GE Logiq 400 MPU ASSY (CPUboard)
Ultrasound Repair Service Siemens X150 BE Board 10131804/Maintenance
Repair Siemens X150 BE board 10131804 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 10131804 4. Compatible with Siemens X150 Various GE/Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to Siemens that we can offer: Brand System Description Siemens S1000/S2000 RM200 10038592 Siemens S1000/S2000 RM220 10853882 10439172 Siemens S2000 RM300 10852163 Siemens S2000 high version/S3000 RM301
Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
Hitachi Aloka HI VISION Preirus troubleshoot color image interference Fault Phenomenon The color ultrasound diagnostic apparatus has a hot wheel interference during use, which seriously affects the diagnosis of the image. Fault analysis and Troubleshooting The color ultrasound diagnostic apparatus has a hot wheel interference during use, which seriously affects the diagnosis of the image. According to the fault phenomenon, each probe of the machine in use has the same
GE Clinic Ultrasound Machine Repair
Common faults of GE ultrasound machine System Faults Solutions LOGIQ 500 No image when scanning far field Check power supply, reinsert the circuit board. Suggest to do metal earthing. LOGIQ 500PRO Artifacts appear in color flow imaging (betweentimes) Replace ACFP3 board LOGIQ 200E No image on displayer, whereas normal image in workstation Fix displayer LOGIQ 200E Curved lines interpolated into sector-shaped image, from near field to far field Replace DSC board, and make sure
IU22 Ultrasound Machine Repair Report Error 201 When Booting Medical Equipments
IU22 Ultrasound Machine Repair Report Error 201 When Booting Medical Equipments 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Enter the background to perform self-test on the equipment, find that the CB board reports an error, and judge the CB board failure; Maintenance result: After replacing the CB board, the equipment is normal. Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound
Original Ultrasound Machine Repair Samsung H60 Monitor And Touch Screen Display Nothing
Samsung H60 Monitor And Touch Screen Display Nothing Ultrasound Machine Repair 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Monitor And Touch Screen Display Nothing Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Knowledge point Importance of maintaining ultrasound machine Paying attention to preventive maintenance is the basic requirement of medical equipment engineers and technicians.
Repair HD15 AIM Ultrasonic Assy 453561197306/Ultrasound Solution
Repair HD15 AIM Ultrasonic Assy (P/N: 453561197306) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 453561197306 4. Compatiable with HD15 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX