Guangzhou Rongtao Medical Tech LTD.
                                                                                                           
Verified Supplier
12 Years
Since 2014
Menu
Home Products Ultrasound Probe Repair

Ultrasound Probe Repair

China GE  RIC5-9A-RS 4D Ultrasound Probe Repair Crystal Replacement for sale Video

GE RIC5-9A-RS 4D Ultrasound Probe Repair Crystal Replacement

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE RIC5-9A-RS 4D Ultrasound Probe Crystal Replacement GE RIC5-9A-RS 4D Probe Change Original Crystal Lines showing up on the screen: Ultrasound probe defects are hardware failures of the ultrasound transducer manifesting as various abnormalities of the scan image, in severe cases even causing complete signal loss. These are a form of ultrasound artifact. Therefore, awareness of the various signs of equipment damage is crucial. It has been shown that regular monitoring of the

China Damage cable sheath Ultrasound Probe Repair  S5 1 for sale Video

Damage cable sheath Ultrasound Probe Repair S5 1

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair S5-1 EPIQ/IU22 Sector Probe Cable Tears on the sheath/ Damage in the cable sheath / Broken cable Tears on the sheath can cause further internal damages to probe and can also hurt the patient. It leads to noise in the picture, a missing connection or lines in the image. It could have been caused by falling on the floor or being hit with another object, wear and tear of the wires, or a cut of the wire by a sharp object. It can even be caused from frequent and

China Toshiba PVU 375BT Ultrasound Probe Repair For Physical Damage for sale Video

Toshiba PVU 375BT Ultrasound Probe Repair For Physical Damage

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Ultrasound Scanner Housing Repair Service Toshiba PVU-375BT Damaged Defective Housing​ Physical damage or broken housing Ultrasound probe casing can be cracked after using for long time or improper handling, dropping of probe, poor storage etc. This needs almost immediate attention or else it may not only be not repairable, but also cause damage to other parts like lens etc. Humidity can enter those small leaks and burst the probe from inside. This will be serious when the

China Siemens Ultrasound Transducer Repair For Lens Fault for sale Video

Siemens Ultrasound Transducer Repair For Lens Fault

Delivery Time: 1-5 work days
Brand: GE, , Siemens, Toshiba, Hitachi Aloka, Biosound

Ultrasound Transducer Repair, Repair Ultrasonic Lens, Crystal, Probe Connector, Cable, Strain Relief, Shell We provide repair service on most common probes, 3D/4D transducers, and Endocavity/TEE probes. With 10 years experiences on probe repair, our technical engineer team owns the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault. Once repaired, all probes will go through an extensive testing process, till reach

China GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement for sale Video

GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes Crystal damage -Weak, dead, or damaged crystals Very often the cause of crystal damage in ultrasound probes is the dropping of probe on the floor or hitting of probe with gel bottle or other object. Once a probe is dropped its piezoelectric crystals may stop sending or receiving signals, resulting in scans with weak or dead elements. This leads to black lines in an image, these lines are called dropouts. Weak

China Motor Control Failures 4D Probe Repair GE RAB2-5-RS for sale Video

Motor Control Failures 4D Probe Repair GE RAB2-5-RS

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Motor Control Failures 4D Probe Motor Repair GE RAB2-5-RS We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes. With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault. Once repaired, all probes will go through an extensive testing process ,until reach their optimal condition. Other hot GE models we can repair:

China Lens Replacement Hitachi Aloka Probe C251 Diagnostic Medical Device for sale

Lens Replacement Hitachi Aloka Probe C251 Diagnostic Medical Device

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Ultrasound Repair Service Lens Replacement Hitachi Aloka Probe C251 We provide repair service on most common probes, 3D/4D transducers, and Endocavity/TEE probes. With 10 years experiences on probe repair, our technical engineer team owns the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault. Main Service Scope Other Hot Models We Repair: Siemens VF12-4 (X700) Siemens VF10-5 (X300) Siemens C8-5 (X300) Siemens 6C1HD

China GE 3SC RS Ultrasound Transducers Repair Damaged Crystals for sale Video

GE 3SC RS Ultrasound Transducers Repair Damaged Crystals

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair GE 3SC-RS Crystal/Crystal Replacement/Damaged Crystals Crystal failure reason Most internal ultrasound probe uses a piezoelectric crystal. After long-term use, it can be causing the crystal of natural aging, and external force such as the use of non-standard or fall off, touch hit will make probe crystal damage, after crystal damaged, B ultrasonic detector detected in the image will appear signal attenuation, the image has dark, black bars, interference, defects such

China Repair GE RAB4 8 D For Oil Leaking for sale Video

Repair GE RAB4 8 D For Oil Leaking

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE 3D 4D Probe Oil Leakage Repair Service Repair Oil-Leaking Rab4-8-D Ultrasonic Sensor​ We provide repair service on most common probes (Linear, convex, sector), 3D/4D transducers, and Endocavity/TEE probes. 3D/4D Probe Repair Service Brand GE,,Siemens Repair Range 3D/4D dome replacement,3D/4D motor repair,Oil and sealing,Strain relief replacement,Crystal/Array replacement,Housing repair,Connecting cable repair Recommended model Samsung V5-9. V6-2/3D9-3V. Siemens 7CF1/7CF2

China Siemens 7CF2 4D Probe Repair Fluid And Oil Leak for sale Video

Siemens 7CF2 4D Probe Repair Fluid And Oil Leak

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair 4D Siemens 7CF2 Acuson Lens Cap/Fluid And Oil Leaks/Leaking Oil Fluid and oil leaks Solution Lens cap replacement, oil reservoir repair and replacement Other hot models we can repair: Brand Model Toshiba PLT-704AT Toshiba PLT-604AT Toshiba PLT-805AT Toshiba PLT-1005BT Toshiba PLT-1204AT Toshiba PLT-704SBT Toshiba PST-30BT Toshiba PST-25ST Toshiba PVM-375AT Toshiba PVT-375BT Toshiba PVT-712BT Toshiba PVM-651VT Toshiba PVM-621VT Toshiba PVT-382BT Toshiba PVT-674BT

China GE 12L-RS Ultrasound Probe Repair For Crystal Array Replacement for sale Video

GE 12L-RS Ultrasound Probe Repair For Crystal Array Replacement

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair Service GE 4C-RS For Array Strain Relief Housing Replacement Crystal Damage We provide repair service on most common probes (Linear, convex, sector), 3D/4D transducers, and Endocavity/TEE probes. With 10 years experiences on probe repair, our technical engineer team owns the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault. Once repaired, all probes will go through an extensive testing process, till reach

China GE RAB2 5 D Ultrasound Probe Repair Strain Relief for sale Video

GE RAB2 5 D Ultrasound Probe Repair Strain Relief

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair 3D/4D GE RAB2-5-D Strain Relief/Missing Connection/Ultrasound Replacement Strain relief separated from connector or head/ Ultrasound probe artifact may lead to noise due to missing connection. A cracked strain relief may occur where the probe attaches to the cable or it may also be seen at the transducer connector location. Strain relief may be getting separated or coming loose from connector or head due to bending, system could have run over the cable, or the

China Damaged Cable Strain Relief Ultrasound Probe Repair GE 4C-D for sale Video

Damaged Cable Strain Relief Ultrasound Probe Repair GE 4C-D

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Damaged Cable Repair Strain Relief Replacement Ultrasound Probe GE 4C-D Cable leakage failure reason and solution Ultrasound probe cable is adopted by high quality of high multi-fiber shielded cable, and good workmanship wires, many hundreds of root, like hair thickness. Due to the bending and torsion of the cable, it makes outside of reserve cable insulating layer will be broken, fracture, revealing the inside line, shielding layer damage, break, corrugated and defect image

China Damaged Cable Ultrasound Probe Repair  V6 2 for sale Video

Damaged Cable Ultrasound Probe Repair V6 2

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair 4D V6-2 IU22/IE33 Cable/Connecting Cable Leakage/Damaged Cable Cable leakage failure reason and solution Ultrasound probe cable is adopted by high quality of high multi-fiber shielded cable, and good workmanship wires, many hundreds of root, like hair thickness. Due to the bending and torsion of the cable, it makes outside of reserve cable insulating layer will be broken, fracture, revealing the inside line, shielding layer damage, break, corrugated and defect

China Samsung EVN4-9 Ultrasound Probe Repair Imaging With Dark Shadows for sale Video

Samsung EVN4-9 Ultrasound Probe Repair Imaging With Dark Shadows

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Strain Relief is worn/dark shadows Samsung EVN4-9 Ultrasound Probe Repair Among the more common issues is a crack or separation in the strain relief. This problem occurs most often where the probe attaches to the cable, but also can occur at the transducer connector. This problem is easy to spot, as shown in the picture on the right. This is one of the most important problems to address quickly because eventually it will affect your image. Ultimately you will damage the wires

China Toshiba PVU-375BT Ultrasound Probe Repair Lens Replacement for sale Video

Toshiba PVU-375BT Ultrasound Probe Repair Lens Replacement

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

Repair Toshiba PVU-375BT Lens/Lens Replacement/Repair Service The lens of failures Reasons An acoustic lens is a gelatinous professional substance that ultrasound probe contacts the upper body.The acoustic lens can cause wear and tear, scratch, crack, corrosion, degumming, blister and other damage after used for long-time.Especially corrosion caused by coupling agent into the lower level.Not only cause blind spots such as artifacts.Causing doctors misdiagnosed.Serious damage

China 3D Ultrasound Probe Repair GE RAB-6-D Transducer Abnormal Image With Air Bubble for sale Video

3D Ultrasound Probe Repair GE RAB-6-D Transducer Abnormal Image With Air Bubble

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

3D 4D Probe Repair GE RAB-6-D Transducer Abnormal Image With Air Bubble Repair time: 2-5 days Warranty: 60 days after fixed We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes. With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault. Once repaired, all probes will go through an extensive testing process,until

China GE RIC5-9-D Ultrasound Transducers Repair Dome Replacement Oil And Sealing for sale Video

GE RIC5-9-D Ultrasound Transducers Repair Dome Replacement Oil And Sealing

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE RIC5-9-D 4d Probe 3D/4D Dome Replacement Oil And Sealing/Diagnostic Medical Device Service We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes. With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault. Once repaired, all probes will go through an extensive testing process,until reach their optimal condition.

China GE RM6C 4d Probe Repair Motor Control Failures for sale Video

GE RM6C 4d Probe Repair Motor Control Failures

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE RM6C 4d Probe Repair Motor Control Failures Repair 3D/4D GE RM6C Motor/Diagnostic Medical Device Service Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be repaired or replaced. Solution Motor repair Other hot GE models we can repair: GE C1-5-D GE C1-5-RS GE 4C GE 4C-RS GE 4C-A GE 4C-D GE 4C-SC GE E8C/E8C-RS GE E8CS GE RIC5-9-D GE 3CRF-D GE C1-6-D GE RAB4-8-RS GE RAB2-5-RS GE 6S-RS GE 12L-RS GE 3SC-RS GE

China 4D Ultrasound Probe Repair Dome Oil And Sealing GE RIC6-12-D Array Replacement for sale Video

4D Ultrasound Probe Repair Dome Oil And Sealing GE RIC6-12-D Array Replacement

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

3D/4D Probe Dome Replacement Oil and sealing GE RIC6-12-D Array replacement We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes. With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault. Once repaired, all probes will go through an extensive testing process ,until reach their optimal condition. Other hot GE

1 2 3 4 5