Siemens 7CF2 4D Probe Repair Fluid And Oil Leak
Repair 4D Siemens 7CF2 Acuson Lens Cap/Fluid And Oil Leaks/Leaking Oil
Fluid and oil leaks
Solution
Other hot models we can repair:
| Brand | Model |
| Toshiba | PLT-704AT |
| Toshiba | PLT-604AT |
| Toshiba | PLT-805AT |
| Toshiba | PLT-1005BT |
| Toshiba | PLT-1204AT |
| Toshiba | PLT-704SBT |
| Toshiba | PST-30BT |
| Toshiba | PST-25ST |
| Toshiba | PVM-375AT |
| Toshiba | PVT-375BT |
| Toshiba | PVT-712BT |
| Toshiba | PVM-651VT |
| Toshiba | PVM-621VT |
| Toshiba | PVT-382BT |
| Toshiba | PVT-674BT |
| Toshiba | PVT-661VT |
| Toshiba | PVT-675MV |
| Toshiba | PVT-575MV |
| Toshiba | PVT-681MV |
| Toshiba | PLU-1204BT |
| Toshiba | PSU-25BT(5S1) |
| Toshiba | PSU-30BT(5S2) |
| Siemens | EV-8C4 (S2000) |
| Siemens | EC9-4(S2000) |
| Siemens | 4V1C (S2000) |
| Siemens | P5-1 (X300) |
| Siemens | 6C1HD (S2000) |
| Siemens | 18L6HD (S2000) |
Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)
| Common ultrasound probe damage | Solutions |
| Lens cap damage | Lens cap replacement |
| Fluid and oil leaks | Lens cap replacement, oil reservoir repair and replacement |
| Cable cuts | Cable patches, possible cable replacement |
| Inoperative steering | Motor repair |
| Connector housing electrical damage | Minor electrical repairs, pin module replacement |
| Weak or dead elements, dropouts in an image | Array ball replacement, oil reservoir repair and replacement |
We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes.
With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault.
Once repaired, all probes will go through an extensive testing process ,until reach their optimal condition.
Storage for Transport of ultrasonic transducer
- Make sure that the transducer is clean and disinfected before placing it in the case to avoid contaminating the foam that lines the carrying case.
- Place the transducer in the case carefully to prevent kinking of the cable.
- Before closing the lid, make sure no part of the transducer is protruding from the case.
- Wrap the case in plastic material containing sealed-air pockets (such as Bubble Wrap material), and pack the wrapped case in a cardboard carton.
Daily and Long-Term Storage of ultrasound transducer
1. Always store transducers in the transducer holders on the side of your system or on a securely mounted wall rack when you are not using them.
2. Ensure the transducer holders are clean before storing transducers
3. When storing transducers, use the cable-management clips, if available, to secure the transducer cable
4. Avoid storing transducers in areas of temperature extremes or in direct sunlight.
5. Store transducers separately from other instruments to avoid inadvertent transducer damage.
6. Before storing transducers, make sure they are thoroughly dry.