Toshiba TX Board Ultrasound Repair Service PM30 32732 1
Toshiba TX Board Small Parts Ultrasound PM30 32732 1
Repair Toshiba Xario 200 TX Board PM30-32732-1/Medical Parts
1. Model: PM30-32733-1
2. Repair time: 2-4 days
3. With 60 days warranty
4. Compatible with Xario 200
Knowledge Point
Toshiba Xario 200 Ultrasound
Toshiba’s Xario 200 ultrasound system takes the worry out of providing high-quality patient care with a smaller, compact ultrasound system. Combining advanced imaging technologies with industry-leading depth and detail, the Xario 200 delivers outstanding clinical performance for routine and advanced studies in the widest range of clinical applications. The system includes an array of ergonomic enhancements automated features to enhance your productivity.
The Xario 200 provides exceptional cost of ownership with the industry’s best technology protection program. All with a sleek, compact system that’s fully loaded and ready to roll into almost any space.
Xario 200’s High-Density Beamformer Architecture produces advanced digital signal processing technology to reveal clinical information never seen before. With comprehensive image enhancement capabilities and an unsurpassed 40 cm depth setting, Toshiba is clearly the leader in delivering best-in-class images for all patient exams.
- Precision Imaging enhances the definition and sharpens the edges of
structures to separate clinical information from noise.
Differential Tissue Harmonic imaging (D-THI)*
- D-THI increases contrast and spatial resolution at greater depths and on difficult-to-image patients.
ApliPure+
- ApliPure+ achieves unparalleled uniformity and detail while preserving clinically significant markers.
Advanced Dynamic Flow (ADF)*
- ADF displays smallest blood vessels and complex blood flow with unequaled accuracy and detail.
Xario 200 systems also feature advanced imaging technologies and quantification tools that extend diagnostic capabilities, increasing confidence in your clinical decision making.
Volume Imaging Suite*
- Volume Imaging Suite captures volume data sets at high—volume rates for shorter exam times and features a comprehensive set of imaging modes (Surface rendering, Muitiview and MPR).
Stress Echo
- Stress Echo enables fast and accurate wall motion assessment and supports both standard and user-definable protocols for exercise and pharmacological stress studies.
Auto- IMT
- Auto-IMT provides an easy-to-use automation tool for measuring intima-media thickness (IMT) of the proximal and distal arterial walls to help determine a patients risk for cardiovascular disease.
Real-time Elastography*
- Real-time Elastography provides a visual representation (color mapping) of the elasticity of lesions following manual compression and helps localize and assess palpable masses with exceptional accuracy, sensitivity and reproducibility.
Other ultrasound parts that we can offer:
| Repair List of Featured Ultrasonic Board & Assy | |||
| Brand | System | Description | Part Number |
| GE | Logiq P5 | APS Power Supply | 5140505/5166108/5329667 |
| GE | Logiq P5 | CPU mainboard | 5168431 |
| GE | Logiq P5 | SYSCONPM | 5177848-3 |
| GE | Logiq P6 | CPU mainboard | |
| GE | Logiq P6 | PST Power Supply | 5245004/5244555 |
| GE | Logiq P6 | SYSCONML | 5252326-3 |
| GE | Logiq S7/Logiq S8 | CPS Power supply | 6626600 R02/5413249-3 |
| GE | Logiq S7 | BF128 transmitting board | 5392446 |
| GE | Logiq S7 | GFS board | 5371196 |
| GE | Logiq S8 | BF192 Beamformer | 5357234-2 |
| GE | Logiq S8 | GFS board | 5371196-2/5455247 |
| GE | Logiq E9/vivid E9 | GTX | GA200726 |
| GE | Logiq E9 | MRX Board | 5393908/5393912 |
| GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
| GE | Logiq E9 | BEP Power Supply | 5393800-3/5166790-2 |
| GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
| GE | Voluson E6/Voluson E8 | RST | KTI301148 |
| GE | Voluson E6/E8/E10 | RSX | KTZ303054 /KTI303054 |
| GE | Voluson E6/E8/E10 | RFM201 FE mainboard | KTZ303916 |
| GE | Voluson E6/E8/E10 | RFM221 FE mainboard | KTZ303915 |
| GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
| GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
| GE | Voluson S6/S8/P8 | BF128 | 5338209-2 |
| GE | Voluson S6/S8/P8 | CPS Power supply | 5393431 |
| GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
| GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
| Aloka | Alpha 5 | mainboard | EP493700DD |
| Aloka | Alpha 6 | RX Beam Former | EP555501AA |
| Aloka | Alpha 6 | CW board | EP555700 |
| Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
| Aloka | Alpha 6 | TX/RX | EP555300 |
| Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
| Aloka | Alpha 7 | RX Beam Former | EP539100BB/EP539500DG/EP539501DG |
| Aloka | Alpha 7 | CPU mainboard | EP558900 |
| Aloka | Alpha 7 | TI Board | EP539000 |
| Aloka | Alpha 7 | TX board | EP548300BB |
| Aloka | Alpha 7 | touch screen | L-Key-93H |
| Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
| Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
| Aloka | Alpha 10 | High-voltage Board | EP541800 |
| Aloka | Alpha 10 | CPU mainboard | EP496000 |
| Hitachi | F31 | RX Beamformer board | EP568900 |
| Hitachi | F31 | mainboard | EP575700BC/EP560800 |
| Hitachi | F37 | TX/RS | EP557400/EP557300 |
| Hitachi | F37 | mainboard | EP575700BC/EP560800 |
| Hitachi | F37 | BF Beamformer board | EP557400 |
| Hitachi | F37 | RX mainboard | EP557500 |
| Aloka | F75 | CONT-B | EP556700BB |
| Aloka | F75 | USP board | EP556600 |
| Aloka | F75 | Cell Board | EP558800 |
| Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
| Hitachi | HI VISION Avius | CONT-B | 7513734A |
| Hitachi | HI VISION Avius/Preirus | Cell board | 7345930A |
| Hitachi | HI VISION Preirus | RX Board | CZH4AA |
| Hitachi | HI VISION Preirus | TX Board | 7513629A |
| Hitachi | HI VISION Preirus | CONT-B | 7513640A/CZ84AJ |
| Hitachi | Arietta 60 | TX | |
| Hitachi | Arietta 60 | RX | |
| Hitachi | Arietta 60 | CELL | EU-9160C |
| Hitachi | Arietta 70 | TX | EP572300AA |
| Hitachi | Arietta 70 | RX | EP572900/EP572200 |
| Hitachi | Arietta 70 | CELL | |
| Hitachi | Noblus | CELL | |
| Hitachi | Noblus | CONT-B | |
| Hitachi | Ascendus | TX | |
| Hitachi | Ascendus | CELL | 7352830A |
| Siemens | X150/G40 | BE | 10131804 |
| Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
| Siemens | X700 | BE | 10136465 |
| Siemens | X700 | RC | 10136467 |
| Siemens | X700 | TI | 11014292 |
| Siemens | Antares | BE | 7472421 |
| Siemens | Antares | CB | 7288504 |
| Siemens | S1000/S2000 | RM200 | 10038592 |
| Siemens | S1000/S2000 | RM220 | 10853882/10439172 |
| Siemens | S2000 | RM300 | 10852163 |
| Siemens | S2000 high version/S3000 | RM301 | 10854749 |
| iU22/iE33 | CB Channel Board | 453561156011/453561156012/453561303902 | |
| iU22/iE33 | AIM Board | 453561210241/453561210243/453561210321/453561210243 | |
| iU22/iE33 | FEC Front End Controller | 453561278261/453561278266/453561464291/453561153751 | |
| iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
| iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
| HD7/Envisor | T/R board | 453561448371 | |
| HD11/HD11XE | SP Board | 453561210154/453561343282 | |
| HD15 | ACB acquisition control board | 453561197145/453561197144 | |
| HD15 | AIM board | 453561197306 | |
| CX50 | CX50 control panel | 453561685791 | |
| CX50 | mainboard | 453561368033/453561622163/453561495832 | |
| CX50 | Power Supply board | 453561375144/453561384831/453561473243 | |
| Affiniti 50 | ACQ acquisition control board | 4535161610416/4535161610426 | |
| Affiniti 70 | ACQ acquisition control board | ||
| EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
| Esaote | Mylab Series | CPU mainboard | 9501361000 |
| Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
| Toshiba | Aplio 300/400/500 | VI | |
| Toshiba | Aplio 300/400/500 | TX | PM30-38691 |
| Toshiba | Aplio 500 | RX | ywm2056*a |
| Toshiba | Xario 200 | TX | PM30-32732-1 |
| Toshiba | Xario 200 | RX | PM30-32733-1 |
| Remarks | |||
| 1.The repair cycle is within 3-5 days. | |||
| 2.Warranty after fixed:60 days. | |||
| 3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
| 4.Package price is available if repair 3 pcs or more at one time. | |||
| 5.Extra discount for VIP partners. | |||
| 6.You could have different part No.under same description. | |||
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.