Cypress 4C1 Convex Ultrasound Transducer Probe B Scan
Siemens 4C1 Convex Ultrasound Transducer Probe
1. Type: convex
2. Frequency: 1.0-4.00 MHz
3. Compatible system:Cypress
4. Application: Adult Abdominal, OB/GYN, Fetal Heart, and Abdominal Vascular
5. Condition: original, in good working condition
6. With 60 days warranty
Knowledge point:
Elastography (ultrasound elasticity imaging)
Ultrasound is also used for elastography, which is a relatively new imaging modality that maps the elastic properties of soft tissue.This modality emerged in the last two decades. Elastography is useful in medical diagnoses as it can discern healthy from unhealthy tissue for specific organs/growths. For example, cancerous tumors will often be harder than the surrounding tissue, and diseased livers are stiffer than healthy ones.
Interventional ultrasonography
Interventional ultrasonography involves biopsy, emptying fluids, intrauterine Blood transfusion (Hemolytic disease of the newborn).
- Thyroid cysts: The high frequency thyroid ultrasound (HFUS) can be used to treat several gland conditions. The recurrent thyroid cyst that was usually treated in the past with surgery, can be treated effectively by a new procedure called percutaneous ethanol injection, or PEI. With ultrasound guided placement of a 25 gauge needle within the cyst, and after evacuation of the cyst fluid, about 50% of the cyst volume is injected back into the cavity, under strict operator visualization of the needle tip. The procedure is 80% successful in reducing the cyst to minute size.
- Metastatic thyroid cancer neck lymph nodes: The other thyroid therapy use for HFUS is to treat metastatic thyroid cancer neck lymph nodes that occur in patients who either refuse surgery, or are no longer a candidate for surgery. Small amounts of ethanol are injected under ultrasound guided needle placement. A blood flow study is done prior to the injection, by power doppler. The blood flow can be destroyed and the node become inactive, although it may still be there. Power doppler visualized blood flow can be eradicated, and there may be a drop in the cancer blood marker test, thyroglobulin, TG, as the node become non-functional. Another interventional use for HFUS is to mark a cancer node one hour prior to surgery to help locate the node cluster at the surgery. A minute amount of methylene dye is injected, under careful ultrasound guided placement of the needle on the anterior surface, but not in the node. The dye will be evident to the thyroid surgeon when opening the neck. A similar localization procedure with methylene blue, can be done to locate parathyroid adenomas at surgery.
- Joint injections can be guided by medical ultrasound, such as in ultrasound-guided hip joint injections.
Other Siemens probes we can offer:
| Brand | Model | Compatible System |
| Siemens | 3.5C55S | G50/X150/X300 |
| Siemens | 6C1HD | S2000 |
| Siemens | 7.5L40A | G20/G40 |
| Siemens | 7.5L75S | G20 and Prima / Adara |
| Siemens | C7F2 | Antares/ X300 and X500 |
| Siemens | CH4-1 | Antares |
| Siemens | CH5-2 | G40/G60/X150/X300 |
| Siemens | CH6-2 | Antares |
| Siemens | CX5-2 | Antares/ Sonoline Elegra |
| Siemens | C6-2 | CV70/ G50/G60/ X300/X500 |
| Siemens | C6F3 | G50/G60 |
| Siemens | C5F1 | Antares |
| Siemens | C8-5 | X300 |
| Siemens | P10-4 | Antares |
| Siemens | PH4-1 | Antares |
| Siemens | P4-2 | G50/G60/CV70/X150/X300/X500 |
| Siemens | P5-1 | X300, X300PE |
| Siemens | EC9-4 | G40/ X150/ X300/Antares |
| Siemens | EV9F4 | X300 and Antares |
| Siemens | VFX9-4 | Antares |
| Siemens | VF13-5sp | Antares/X300/X500/G50/G60 |
| Siemens | VFX13-5 | Antares |
| Siemens | VF13-5 | X150/X300/X500/G40 /G50/G60/ Sonoline Sienna/Sonoline Elegra |
| Siemens | VF13-5 | Antares |
| Siemens | VF10-5 | Antares |
| Siemens | 4V1C | Sequoia 512 GI, Sequoia C512, S2000 |
| Siemens/Acuson | 4V1 | Sequoia |
| Siemens/Acuson | 6L3 | Acuson Sequoia |
| Siemens/Acuson | 8C4 | Sequoia 512 G /Sequoia C512 |
| Siemens/Acuson | 8L5 | Sequoia 512 |
| Siemens/Acuson | 8V5 | Sequoia |
| Siemens/Acuson | 7L3 | Cypress |
| Siemens/Acuson | 8V3 | Sequoia 512 /S1000 |
| Siemens/Acuson | 9EVF4 | S1000/ S2000 and S3000 |
| Siemens/Acuson | 9L4 | Acuson S2000/ Sequoia/Sequoia C512 |
| Siemens/Acuson | 10V4 | Sequoia |
| Siemens/Acuson | 15L8W | Sequoia 512 |
| Siemens/Acuson | 15L8 | Sequoia |
| Siemens/Acuson | 17L5HD | Sequoia 512 |
| Siemens/Acuson | 18L6HD | S1000, S2000, S3000 |
| Siemens/Acuson | AUX CW | Cypress / Cypress CV System |
| Siemens/Acuson | C3 | Aspen |
| Siemens/Acuson | EC9-4 | G40/ G60/X150/ X300 |
| Siemens/Acuson | EC7 | Aspen/ XP128 |
| Siemens/Acuson | EV-8C4 | Sequoia 512/ S2000 |
| Siemens/Acuson | EC-10C5 | Sequoia 512 |
| Siemens/Acuson | L5 | Aspen |
| Siemens/Acuson | L7 | Aspen/128XP-10 |
| Siemens/Acuson | TE-V5M | Sequoia/ Sequoia C512/Sequoia 512/ Aspen/ Cypress/S1000/S2000 |
| Siemens/Acuson | TE-V5Ms | Cypress/Sequoia/S2000/X300 systems |
| Siemens/Acuson | V4 | Aspen/ XP |
| Siemens/Acuson | V7 | Aspen/ XP |
Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)
| Common ultrasonic probe damage | Solutions |
| Lens damage, wear, holes, swelling, delamination | Lens replacement |
| Strain relief damage, separation | Strain replacement |
| Nosepiece and probe separation and cracks | Strain replacement |
| Cable cuts | Cable patches, possible cable replacement |
| Connector housing electrical damage | Major and minor electrical repairs, pin module replacement |