Motor Control Failures 4D Probe Repair GE RAB2-5-RS

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days
Brand: GE
Product Description

 

Motor Control Failures 4D Probe Motor Repair GE RAB2-5-RS

 

 

We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes.

With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault.

Once repaired, all probes will go through an extensive testing process ,until reach their optimal condition.

 

 





 

 

Other hot GE models we can repair:

 

GE C1-5-D
GE C1-5-RS
GE 4C
GE 4C-RS
GE 4C-A
GE 4C-D
GE 4C-SC
GE E8C/E8C-RS
GE E8CS
GE RIC5-9-D
GE 3CRF-D
GE C1-6-D
GE RAB4-8-RS
GE RAB2-5-RS
GE 6S-RS
GE 12L-RS
GE 3SC-RS
GE L6-12-RS
GE 11L
GE 11L-D
GE 12L-RS
GE 8C
GE 3S
GE 3S-RS
 

 

 

 

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

 

Common ultrasound probe damage Solutions
Lens cap damage Lens cap replacement
Fluid and oil leaks Lens cap replacement, oil reservoir repair and replacement
Cable cuts Cable patches, possible cable replacement
Inoperative steering Motor repair
Connector housing electrical damage Minor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an image Array ball replacement, oil reservoir repair and replacement

 

 

 

Warnings and cautions of ultrasonic probe

 

The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou Rongtao Medical Tech LTD.
Location Room 201, 203, Building C ,No. 26, Ningcai Road, Huangpu District, Guangzhou, China
Contact Person Aurora Zhu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.