33KV Gas Insulated Switchgear
SF6 Metal-Clad Enclosed Ring Main Unit
12 24 36KV50/60Hz, 630,1250A
OEM & ODM,Complete equipment
Meet IEC standards
Send us your SLD (Single Line Drawing) or requirements, we design the switchgear plan for you
Product Introduction
General
The ring network refers to the ring power distribution network, that is, the power supply mainline forms a closed-loop, and the power supply supplies power to the ring main line and then distributes power all the way from the mainline through the high-voltage switch. The advantage of this is that each power distribution branch can take power from its left mainline and its right mainline. When the left mainline fails, it continues to receive power from the right mainline, and when the right mainline fails, it continues to receive power from the left mainline. In this way, even though the main power supply is the single-circuit power supply, However, from each distribution branch, the benefits similar to the dual power supply are obtained, thereby improving the reliability of the power supply.
Service Environment
1. Air temperature: -35℃~+40℃
2. Humidity: Monthly average humidity 95%; Daily average humidity 90%.
3. Altitude2500m
4. Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
5. No frequent violent shake
Technical Data
| No. | Item | Unit | Parameter | |||
| 1 | Rated voltage | kV | 12 | 24 | 36 | |
| 2 | Rated frequency | Hz | 50/60 | |||
| 3 | Rated current | A | 630(1250*) | |||
| 4 |
1min Power frequency withstand voltage |
wet | kV | 38 | 50 | 70 |
| dry | kV | 48 | 60 | 85 | ||
| 5 | Lightning impulse withstand voltage | kV | 75 | 125/150 | 170 | |
| 6 | Rated short circuit breaking current (peak) | kA | 80 | 63 | 63 | |
| 7 | Rated active load and close circuit breaking current | A | 63 | 50 | 50 | |
| 8 | Rated transferring current | A | 1700 | 1200 | 1200 | |
| 9 | Rated short circuit making current (peak) | kA | 80 | 63 | 63 | |
| 10 | Rated cable(line) charging breaking current | A |
50 and 10 50/10 |
|||
| 11 | Cable charge breaking current in earthing fault | A | 20 | 20 | 20 | |
| 12 | Rated withstand current (peak) | kA | 80 | 63 | 63 | |
| 13 | Short-time withstand current (2s) | kA | 25 | 20 | 20 | |
| 14 | Mechanism life | times | 5000 | 2000 | 2000 | |
Note: For short circuit breaking and peak current is based on Fuse plus combination