Photoelectric Smoke Alarm With 10-Year Lithium Battery Battery Operated CO Detector
Photoelectric Smoke Alarm With 10-Year Lithium Battery Battery Operated CO Detector
Photoelectric smoke detector fire alarm use a photoelectric sensor to quickly detect smoldering, slow burning smoke from wide ranges before catching flames. The fire detector does not contain any radioactive material, fire-retardant and eco-friendly material free from harsh smells and chemicals, making it great for bedrooms.
Home smoke detectors alerts of smoldering smoke sounding a clear 85-decibel and blinking LED light. Use microprocessor control, no false alarms. This smoke alarm meets TUV CE certification for approved installation and safety requirements for homes depot businesses hotel school office.
Wireless smoke detector is operated by a 9V battery(included) for wireless, hassle-free installation and no worry potential outages during a power failure. The long-lasting battery and life span reduces reminders for battery changing, flashing red LED lights to signal when a battery change is needed.
Easy-to-use smoke alarm includes a with a silence/ single test button to silence the hush functionality and quickly test the home fire alarm during monthly check-ups.
Great fire alarm for home, office, business, apartments, garage, hospital, classroom. Also it perfect as a gift for Christmas, birthday and holiday. If you need any assistance or have any confused, just email us, we are always here to help you with any problem.
Sepcification
| Product name | Photoelectric Smoke Alarm With 10-Year Lithium Battery |
|
Audible alarm
|
≥85 dB at 3m
|
|
Working distance
|
Up to 100m (Outdoor open) |
|
Frequency
|
433.92MHz or 868MHz (Customized)
|
|
Temperature
|
0℃~40℃
|
|
Humidity
|
≤95%RH non-condense
|
| Battery | 10-Year Lithium Battery |
| Operation Current | <10uA (standby); <70mA (alarm) |
| Alarm Sensitivity | 0.09 - 0.17 dB/m |
| Silence Time | Approx. 10 minutes |
2. Test status: Red LED flashes once every second.
3. Hush/Silence mode: Red LED flashes once every 8 seconds.
4. Low Battery status: Red LED flashes once every 60 seconds and 1 beep every 60 seconds.
5. Fault status: the alarm will deliver beeps every 40 seconds.

Radio-interlinked smoke detectors are interlinked through radiofrequency signals. If one smoke alarm detects fire, all alarms go
off. In the case of the battery operated radio-interlinked smoke alarms, no wiring is required at all.
Step 1: Press the test/silence button on one of these smoke alarms 4 times, and the green LED will rapidly flash continuously, indicating it has entered the transmitting mode (valid time: 60 seconds) .
Step 2: Press the test/silence button on the other smoke alarms twice, and the green LED will slowly flash continuously,indicating it has entered the receiving mode.
-----When it is failure: The green light will continue to flash for 60 seconds, and then the red light will stay on for 2 seconds.
Press the test/silence button on the smoke alarms twice and the green LED will slowly flash continuously still 60 seconds, then ignore it and it will automatic despairing.
How to silence the alarms in network when alarm
If the smoke alarm detects fire, the device will goes into Source/Master smoke alarm sound pattern alarmed, and emits the alarm signal;
When other alarm devices received alarm signal, they will goes into Slave smoke alarm sound pattern, until the Source/Master alarm device stopped alarm; During the unit is alarming, you can find out the Source/Master smoke alarm , press the Test/Silence button to pause all other
interconnected alarms.

1. The low battery signal can last for maximum 30 days, please replace the batteries in time to keep it working properly.
2. Battery required: 10-Year Lithium Battery
3. Acceptable brand: Duracell MN1500, Golden Peak LR6, GP GN15A, etc.
4. Correctly install the positive and negative poles of the battery (“+” & “-”)
5. Waste batteries should not be placed into any household waste or recycling bin as all of them have the potential to spark. Check with your Local Authority for recycling advice.
Q: How can i place an order?
Please provide the details of your requirements as clear as possible. So we can send you the offer at the first time.
A: For designing or further discussion, it is better to contact us with Skype / email / phone, in case of any delays.
Q: How about the quality of the personal alarm ?
A:We produce every product with good quality materials and fully test three times before shippment. What is more, our quality
areapproved by CE RoHS SGS & FCC, IOS9001, BSCI.
Q: Can i have a sample order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q:What is your terms of delivery?
A: We accept EXW, FOB, CFR, CIF, DDU, DDP, etc. You can choose the one which is the most convenient or cost effective for you.
Q: How do you ship the goods and how long does it take arrive?
A:We usually ship by DHL(3-5days), UPS(4-6days), Fedex(4-6days), TNT(4-6days), Air(7-10days), or by sea(25-30days)at your request.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.