China World Technology Medical Equipment Service Group
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

Mindray IMEC8 Patient Monitor Parts LED Light Board 6301 Alarm Board PCBA 051-000879-01

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5 working days
Brand: Mindray
Product Description

 

Mindray iMEC8 Patient Monitor LED Light Board 6301 Alarm Board PCBA 051-000879-01

 

 

 

►Brief Introduction

The alarm lamp board is located at the top of front housing. It has two-color indicators, red and yellow. The alarm lamp board directly connects the main board through a cable. It is controlled directly by the main board.

The LED Light Board and Alarm Board are two separate printed circuit boards (PCBA) used in the Mindray iMEC8 Patient Monitor.

The LED Light Board is responsible for providing visual indications for the physiological parameters being measured and displayed on the monitor. The board consists of a number of LED lights, each representing a specific parameter such as heart rate, blood pressure or oxygen saturation.

The Alarm Board, on the other hand, is responsible for monitoring the physiological parameters being measured and sounding an audible alarm when any of them goes beyond their pre-set limits. This board is connected to sensors attached to the patient and continuously monitors their vital signs. It triggers an alarm when any of the readings go beyond their normal ranges indicating a potential medical emergency.

Both these boards are integral components of the Mindray iMEC8 Patient Monitor and help medical professionals quickly and accurately diagnose the patient's condition. They work by receiving and interpreting data from sensors attached to the patient, and providing visual and audible notifications to the medical staff when any of the parameters are abnormal.

 

 

 

► Alarm Lamp Problems

Symptoms Possible Cause Corrective Action
The alarm lamp is not light or extinguished, or the alarm lamp illuminates abnormally Cable defective or poorly connected 1. Check that the cable from alarm LED board to main board is properly connected.
2. Check that connecting cables and connectors are not damaged.
Alarm LED board failure Replace the alarm LED board.

 

 

 

Removing the Alarm Lamp Board

Unscrew the two PT3X8 screws indicated below and take out the alarm lamp board.

 

 

 

► Repair operations

As an experienced medical device industry expert, Apart from specializing in selling medical devices, accessories and repair parts such as patient monitor, defibrillator machine, patient monitor printer, ECG machine, EKG machine, main board, batteries and so on, we also engage in providing medical equipments or modules repair service. So if you have any that sort of machine or modules which in need of repair, please feel free to contact us at any time. Moreover, what need to pay attention to is that you have to make sure the repair item is unopened and has never been repaired before. And items lack of component is unacceptable. Accordingly, check out your item before shipping.

 

 

 

► About Us

We have supply the Parts, Accessories and medical equipment of Patient Monitor, Defibrillator Machine, ECG Machine, Ventilator, Anesthesia Machine, Ultrasound such as

  • GE,
  • PHiliphhilip,
  • Mindray,
  • Goldway,
  • Nihon Kohden,
  • Med-tronic,
  • Masima,
  • Drager,
  • Edan,
  • Zoll,

etc.

 

 

If you want to explore more details about Mindray iMEC8 Patient Monitor LED Light Board 6301 Alarm Board PCBA 051-000879-01, please let us know. Looking forward to receiving your early inquiry.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.