China World Technology Medical Equipment Service Group
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

Nihon Kohden TEC-5602 Defibrillator Alarm Indicator Board UR-0493 6190-909778 for Hospital Operating Room

Price Negotiable
Price: USD
MOQ: 1
Delivery Time: 3-5 Working Days
Brand: Nihon Kohden
Product Description

             

Nihon Kohden TEC-5602 Defibrillator Alarm Indicator Board UR-0493 6190-909778 for Hospital Operating Room

 

 

►Quick Detail:

 

Common faults of defibrillators


①Cannot turn on the machine, the AC indicator light is on, and the switch encoder is broken.

②The self-test cannot be passed, the energy cannot be charged to the preset value, and the power PCA is broken.

③If an error is reported, it is mostly due to a bad power PCA.

 

④It can only work with batteries and cannot use AC power. The power supply of the whole machine is broken

⑤Turn on the machine and enter self-test mode, and the panel is short-circuited.

⑥Display back panel.

⑦There are many broken motherboards.

 

⑧It reports low battery, but the battery is full. Capacity detection circuit problem.

⑨No sound, no display, the motherboard is broken.

 

This product is Nihon Kohden TEC-5602 Defibrillator Alarm Indicator Board UR-0493 6190-909778,When determining the main board fault of the defibrillator, please find a professional engineer to inspect and repair it, determine whether it is the main board fault, and find the accurate replacement model of the main board.

 

 

 

 

                                     

 

 

 

Precautions:

 

As an important component of medical equipment, multi parameter electrocardiogram monitors play a crucial role in the medical process. Over time, multi parameter electrocardiogram monitors may also experience various malfunctions. Common malfunctions include power on system failure, irregular or no electrocardiogram waveform, communication system failure, blood oxygen saturation measurement failure, non-invasive blood pressure measurement failure, and so on.
We medical equipment engineers need to deeply learn and understand the system structure and working principle of electrocardiogram monitors, so that in the future, when encountering faults, we can quickly identify the cause of the fault and repair it, ensure the normal operation of hospital medical equipment, help medical personnel timely grasp the patient's physiological condition, timely raise emergency alarm signals, and provide emergency conditions, which is conducive to improving the efficiency of rescue and effectively reducing the workload of hospital doctors.

 

 

Key features:

 

 

Type: Nihon Kohden TEC-5602 Defibrillator Alarm Indicator Board UR-0493 6190-909778
Warranty period: 90 Days
Shipping Date: 3-5 Working Days
MODEL:

UR-0493 6190-909778

Storage temperature: -20-70°c
MOQ: 1 PCS
COLOR: Green
Delivery Date: 3 - 5 Working Days
Package Standard export packaging

 

 

► Company situation:

 

The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.

 

About delivery:

 

We default to express delivery by DHL,Fedex,etc.We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.

 

 

 

 

 

 

 

 


 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.