P/N 453564015271 453564052551 VM6 Patient Monitor Parts Nibp Pump Module
P/N 453564015271 453564052551 PHiliphhilip VM6 Patient Monitor Nibp Pump Module
NBP Introduction
Oscillometric using stepwise deflation pressure
• Adult/pediatric measurement range
– Systolic: 30 – 255 mmHg
– Diastolic: 15 – 220 mmHg
– Mean: 20 – 235 mmHg
• Neonatal measurement range
– Systolic: 30 – 135 mmHg
– Diastolic: 15 – 110 mmHg
– Mean: 20 – 125 mmHg
• Blood pressure accuracy: ±5 mmHg
• Pulse rate accuracy: ±2
Removing the NBP Module
Caution :After replacing the NBP module, you must reset the NBP cycle count and run the NBP test
Step :
- Separate the front and rear monitor case assemblies
- Remove the main board assembly
- Remove the front end assembly
- Remove the two Torx T10 screws and washers from the metal bracket holding the NBP module assembly to the bottom of the main board
- Lift the NBP module and gently pull it free from the pressure sensor tube connectors
- Disconnect the 6-pin connector from the main board and remove the NBP module.
Removing the NBP Filter
- Separate the front and rear monitor case assemblies
- Remove the main board assembly
- Remove the front end assembly
- Remove the NBP module
- Use wire cutters to cut the plastic zip tie securing the filter to the module, and disconnect the filter from the NBP filter tube
Caution: When you replace the NBP filter, secure it to the NBP module with a new plastic zip tie.
| Item name |
PHiliphhilip VM6 patient monitor nibp pump 453564015271 453564052551
|
| Brand | PHiliphhilip |
| Model |
453564015271 453564052551
|
| Use place | Hospital Devices; Medical Care; ICU; |
| Deliver time | 3-5 days |
| Warranty | 90 days |
Identify NBP hardware modules
The VM series patient monitors support two types of NBP hardware modules: PHiliphhilip and CAS. The steps to monitor NBP are the same whether the monitor contains a PHiliphhilip or CASNBP module. However, the upper and lower limits of PHiliphhilipysiological NBP alarms, the conditions that lead to technical NBP alarms, and the range of initial inflation pressure settings are different for the PHiliphhilip and CASNBP modules.
Step :
1. Rotate the wheel until the System button is highlighted.
2. Press the wheel key. The System menu appears.
3. View the Configuration settings. The type of NBP module appears as one of the following:
NBP-P - PHiliphhilip NBP Module
NBP-C-CAS NBP Module
FAQ
- What’s the condition ?
Some products have refurbished and original new ,some have only original,which depends on products .
- Can i order one sample firstly ?
Sure,our MOQ is one piece ,It’s totally okay to order one sample to try .
- Can you accept cash on delivery ?
I’m sorry we cannot accept that .Even our VVIP customers order are shipped out after receiving full payment .Thank you for your cooperation .
- How fast can i receive the order ?
We ship by DHL,Fedex ,UPS ,around 5-7 working days to arrive on your side .
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.