F14 Terminal Sealed Vrla 12v90ah UPS Battery Lead Acid 306*169*211mm
Stable quality Sealed vrla 12v 90ah UPS lead acid battery for solar system
>Summary
1.Why UPS use lead-acid batteries?
The reason why lead acid batteries are preferred for UPS applications is the lower cost and relatively lower-tech battery
management requirements.
Lead acid battery performance degrades for several reasons. In an uninterruptible power supply,
the battery set is used in a standby power application.
2.How long do UPS lead-acid batteries last?
UPS batteries (traditional sealed lead-acid batteries) tend to have either a 5-years or 10-years design life.
Some may last for 10-15 years.
Yet performance will significantly reduce overtime to a degree where it is not safe to use in a UPS system.
So you should figure out its service life instead of design life.
| Battery Model No. | FBR12V90Ah | |
| Nominal Voltage | 12V | |
| Capacity | 20HR(5.25V) | 90Ah |
| (25ºC) | 10HR(5.25V) | 79Ah |
| 1HR(4.80V) | 55.6Ah | |
| Dimension | Length | 306±2mm |
| Width | 169±2mm | |
| Height | 211±2mm | |
| Total height | 214±2mm | |
| Approx. Weight | 27kg±4% | |
| Terminal type | F14 | |
| Internal resistance | Approx 5mΩ | |
| (Fully charged,25ºC) | ||
| Capacity affected by | 40ºC | 102% |
| Temperature(20HR) | 25ºC | 100% |
| 0ºC | 85% | |
| -15ºC | 65% | |
| Self-discharge(25ºC) | 3month | Remaining Capacity:91% |
| 6month | Remaining Capacity:82% | |
| 12month | Remaining Capacity:65% | |
| Nominal operating temperature | 25ºC±3ºC(77ºF±5ºF) | |
| Operating | Discharge | -15ºC-50ºC(5ºF-122ºF) |
| temperature range | Charge | -10ºC-50ºC(14ºF-122ºF) |
| Storage | -20ºC-50ºC(-4ºF-122ºF) | |
| Float charging voltage (25ºC) |
13.5 to 13.8V Temperature compensation:-18mV/ºC |
|
| Cyclic charging voltage (25ºC) |
14.5 to 15V Temperature compensation:-30mV/ºC |
|
| Max charging current | 27A | |
| Max discharging current | 800A(5sec.) | |
| Designed floating life(20ºC) | 10years | |
| Component | Positive plate | Negative plate | Container | Cover | Separator | Electrolyte | Safety valve | Terminal |
| Raw material | Lead dioxide | Lead | ABS | ABS | AGM | Sulfuric acid | Rubber | Copper |

| F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
| 9.6V | 262 | 202 | 121 | 74.2 | 43.8 | 31.2 | 25.2 | 21.5 | 14.8 | 12.2 | 6.47 |
| 9.9V | 254 | 197 | 118 | 73 | 43.6 | 31 | 25.1 | 21.4 | 14.7 | 12.2 | 6.46 |
| 10.2V | 243 | 190 | 115 | 71.2 | 43.2 | 30.8 | 24.9 | 21.3 | 14.6 | 12.2 | 6.44 |
| 10.5V | 233 | 183 | 112 | 69.7 | 42.6 | 30.6 | 24.7 | 21.1 | 14.5 | 12.1 | 6.4 |
| 10.8V | 220 | 173 | 108 | 67.6 | 41.5 | 29.7 | 24 | 20.5 | 14.1 | 12 | 6.36 |
> Constant Power Discharge Characteristics(Watt,25ºC)
| F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
| 9.60V | 2825 | 2214 | 1353 | 845 | 508 | 367 | 297 | 255 | 176 | 146 | 77.7 |
| 9.90V | 2741 | 2160 | 1326 | 833 | 505 | 365 | 295 | 253 | 175 | 146 | 77.5 |
| 10.2V | 2628 | 2081 | 1285 | 812 | 500 | 362 | 293 | 251 | 174 | 145 | 77.3 |
| 10.5V | 2514 | 2010 | 1254 | 795 | 493 | 360 | 291 | 250 | 172 | 144 | 76.9 |
| 10.8V | 2373 | 1904 | 1208 | 770 | 480 | 349 | 282 | 242 | 167 | 143 | 76.3 |


1.Solar and wind energy storage system;
2.EPS and UPS battery backup;
3.Signal system , emergency lighting system , security system;
4.Telecommunication Equipment;
5.Power source for portable devices or tools.


A1: Tell us your demand, Then our sales staff will recommend a suitable battery for you.
Q2. Do you have any MOQ limit?
A2: Yes, we have MOQ for mass production, It depends on the model. 50-500pcs sample order is available. for sample checking is available.
Q3. Is it OK to print my logo on the product?
A3: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
Q4: How to solve the technical problem?
A4: 24 hours after-service consultancy just for you and to make your problem to solve easily.
Q5:. What certificate your company have?
A5: ISO 9001, ISO 14001, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.
Q6.What is your warranty time for VRLA battery ?
A6: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.
Q7. Why battery has different capacity at different hour rate?
A7: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.
Q8. Are you a battery manufacturer, and do you produce the plate by yourself ?
A8: Yes, we are a professional battery manufacture in Fujian Province, China. And we produce plates by ourselves.
Q9. How to proceed with an order?
A9. Firstly let us know your requirements or application. Secondly, We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places a deposit for formal order.
Fourthly We arrange the production.
Q10: How about the delivery time?
A10: About 7 days for stock products, around 20 days for half container products, 20 foot container products for 30 days.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.