Factory deep cycle gel battery 12v 200ah AGM Lead Acid Battery for wind and Solar system
Factory deep cycle gel battery 12v 200ah AGM Lead Acid Battery for wind and Solar system
>Main Features
1.What is an AGM Battery?
AGM Technology Explained AGM batteries are based on the standard SLA (sealed lead-acid) battery construction. The difference lies in the addition of an ultra-thin glass mat (or AGM separator) that "absorbs" the electrolyte and makes the battery non-spillable. A sealed lead-acid battery is also known as a VRLA battery.
2.AGM Battery vs. Other Batteries
Although AGM, gel, and flooded batteries are classified as lead-acid batteries, AGM batteries stand out in the internal construction of the battery. AGM batteries are easy to install, with zero maintenance and gas formation.free maintenance and spill-proof design make an AGM battery extremely suitable as a solar battery.The construction of an AGM battery is suitable for systems that require high currents (such as starting an engine). Furthermore, AGM battery poles can be unscrewed for the battery to be combined with any other standard battery terminal.
A battery type differs in price and lifespan. For example, an AGM battery is believed to last around 600 cycles, but a lithium battery may last 7,000 cycles. In addition, AGM batteries are expensive than flooded batteries and cheaper than gel batteries.
3.AGM battery vs. Gel battery
Both AGM and gel batteries are categorized as VRLA batteries that are known for easy maintenance. Unlike an AGM battery, a gel cell battery uses a special type of silica gel to hold the electrolytes together and facilitate the free movement of electrons from the plates.
Gel batteries lose power faster at lower temperatures, but AGM batteries work well even in extreme weather conditions.
Moreover, a deep cycle gel battery has other disadvantages, such as a shorter lifespan and slower charging time than a deep cycle AGM battery.
4.AGM battery vs. Lead-acid battery
How is an AGM battery different from a typical lead-acid battery? Unlike conventional lead-acid batteries, AGM batteries provide better cycling performance and faster charging performance.
AGM batteries demonstrate minimal gassing and acid leakage, last longer and are resistant to freezing. Furthermore, the spill-proof and leak-proof design makes it easier to mount an AGM battery in any direction.
| Battery Model No. | FBR12V200Ah | |
| Nominal Voltage | 12V | |
| Capacity | 20HR(5.25V) | 200Ah |
| (25ºC) | 10HR(5.25V) | 176Ah |
| 1HR(4.80V) | 124Ah | |
| Dimension | Length | 522±2mm |
| Width | 238±2mm | |
| Height | 218±2mm | |
| Total height | 221±2mm | |
| Approx. Weight | 59.5kg±4% | |
| Terminal type | F13 | |
| Internal resistance (Fully charged,25ºC) |
Approx 3.5mΩ | |
| Capacity affected by | 40ºC | 102% |
| temperature(20HR) | 25ºC | 100% |
| 0ºC | 85% | |
| -15ºC | 65% | |
| Self-discharge | 3month | Remaining Capacity:91% |
| (25ºC) | 6month | Remaining Capacity:82% |
| 12month | Remaining Capacity:65% | |
| Nominal operating temperature | 25ºC±3ºC(77ºF±5ºF) | |
| Operating | Discharge | -15ºC-50ºC(5ºF-122ºF) |
| temperature range | Charge | -10ºC-50ºC(14ºF-122ºF) |
| Storage | -20ºC-50ºC(-4ºF-122ºF) | |
| Float charging voltage | 13.5 to 13.8V | |
| (25ºC) | Temperature compensation:-18mV/ºC | |
| Cyclic charging voltage | 14.5 to 15V | |
| (25ºC) | Temperature compensation:-30mV/ºC | |
| Max charging current | 60A | |
| Max discharging current | 1600A(5sec.) | |
| Designed floating life(20ºC) | 10years | |
| Component | Positive plate | Negative plate | Container | Cover | Separator | Electrolyte | Safety valve | Terminal |
| Raw material | Lead dioxide | Lead | ABS | ABS | AGM | Sulfuric acid | Rubber | Copper |

It is widely used in communication equipment, UPS/EPS power supply, medical equipment, emergency lamp,
aviation signal, railway signal,alarm and safety system, instrument and instrument system.

| F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
| 9.6V | 436 | 336 | 201 | 124 | 73.1 | 52 | 42 | 35.9 | 24.7 | 20.4 | 10.8 |
| 9.9V | 423 | 328 | 197 | 122 | 72.6 | 51.7 | 41.8 | 35.7 | 24.5 | 20.3 | 10.8 |
| 10.2V | 405 | 316 | 191 | 119 | 72 | 51.4 | 41.5 | 35.4 | 24.4 | 20.3 | 10.7 |
| 10.5V | 388 | 305 | 186 | 116 | 70.9 | 51 | 41.2 | 35.2 | 24.2 | 20.1 | 10.7 |
| 10.8V | 366 | 289 | 179 | 113 | 69.1 | 49.5 | 41 | 34.1 | 23.5 | 20 | 10.6 |
>Constant Power Discharge Characteristics(Watt,25ºC)
| F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
| 9.60V | 4709 | 3689 | 2255 | 1409 | 846 | 612 | 494 | 424 | 293 | 243 | 129 |
| 9.90V | 4568 | 3601 | 2210 | 1388 | 841 | 608 | 491 | 422 | 292 | 243 | 129 |
| 10.2V | 4379 | 2468 | 2142 | 1353 | 834 | 604 | 488 | 419 | 290 | 242 | 129 |
| 10.5V | 4191 | 3350 | 2091 | 1324 | 821 | 600 | 485 | 416 | 287 | 240 | 128 |
| 10.8V | 3955 | 3173 | 2014 | 1284 | 800 | 582 | 470 | 404 | 279 | 239 | 127 |


A1: Tell us your demand, then our sales will recommend a suitable battery for you.
Q2. Do you have any MOQ limit?
A2: Yes, we have MOQ for mass production, it depends on the different model numbers.
Q3. Is it OK to print my logo on the product?
A3: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
Q4: How to solve the technical problem?
A4: 24 hours after-service consultancy just for you and to make your problem to solve easily.
Q5:. What certificate your company have?
A5: ISO 9001, ISO 14001, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.
Q6.What is your warranty time for VRLA battery ?
A6: It depends on battery capacity, depth of discharge, and battery usage.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.