X20CP3586 B&R Automation Plc 1.6 GHz CPU Processor For X20 PLC System Module
Price:
USD
MOQ:
1EA
Delivery Time:
Negotiable
Brand:
B&R
Product Description
General information
| B&R ID code | 0xBF2B |
| Cooling | Fanless |
| Status indicators | CPU function, Ethernet, POWERLINK, CompactFlash, battery |
| Diagnostics | |
| Battery | Yes, using LED status indicator and software |
| CPU function | Yes, using LED status indicator |
| CompactFlash | Yes, using LED status indicator |
| Ethernet | Yes, using LED status indicator |
| POWERLINK | Yes, using LED status indicator |
| Temperature | Yes, using software register |
| Support | |
| Controller redundancy | Yes |
| Storage health data support | Yes |
| ACOPOS support | Yes |
| Visual Components support | Yes |
| Power consumption without interface module and USB | 9.7 W |
| Power consumption for X2X Link power supply | 1.42 W |
| Power consumption | |
| Internal I/O | 0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| Certifications | |
| CE | Yes |
| UKCA | Yes |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B(0 - 55°C) Humidity: B(up to 100%) Vibration: B(4 g) EMC: B(bridge and open deck) |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| EAC | Yes |
| KC | Yes |
CPU and X2X Link power supply
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 1.5 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
X2X Link power supply output
| Nominal output power | 7 W |
| Parallel connection | Yes |
| Redundant operation | Yes |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Permissible contact load | 10 A |
Power supply - General information
| Status indicators | Overload, operating status, module status, RS232 data transfer |
| Diagnostics | |
| RS232 data transfer | Yes, using LED status indicator |
| Module run/error | Yes, using LED status indicator and software |
| Overload | Yes, using LED status indicator and software |
| Electrical isolation | |
| I/O supply - I/O power supply | No |
| CPU/X2X Link supply - CPU/X2X Link power supply | Yes |
Controller
| CompactFlash slot | 1 |
| Real-time clock | Nonvolatile, resolution 1 s, -10 to 10 ppm accuracy at 25°C |
| FPU | Yes |
| Processor | |
| Type | Atom E680T |
| Clock frequency | 1.6 GHz |
| L1 cache | |
| Data code | 24 kB |
| Program code | 32 kB |
| L2 cache | 512 kB |
| Integrated I/O processor | Processes I/O data points in the background |
| Modular interface slots | 3 |
| Remanent variables | Max. 1 MB |
| Shortest task class cycle time | 100 µs |
| Typical instruction cycle time | 0.0027 µs |
| Data buffering | |
| Battery monitoring | Yes |
| Lithium battery | Min. 2 years at 23°C ambient temperature |
| Standard memory | |
| RAM | 512 MB DDR2 SDRAM |
| User RAM | 1 MB SRAM |
Interfaces
| Interface IF1 | |
| Signal | RS232 |
| Variant | Connection via 12-pin terminal block X20TB12 |
| Max. distance | 900 m |
| Transfer rate | Max. 115.2 kbit/s |
| Interface IF2 | |
| Signal | Ethernet |
| Variant | 1x RJ45 shielded |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | 10/100/1000 Mbit/s |
| Transfer | |
| Physical layer | 10BASE-T/100BASE-TX/1000BASE-T |
| Half-duplex | Yes |
| Full-duplex | Yes |
| Autonegotiation | Yes |
| Auto-MDI/MDIX | Yes |
| Interface IF3 | |
| Fieldbus | POWERLINK (V1/V2) managing or controlled node |
| Type | Type 4 |
| Variant | 1x RJ45 shielded |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | 100 Mbit/s |
| Transfer | |
| Physical layer | 100BASE-TX |
| Half-duplex | Yes |
| Full-duplex | POWERLINK mode: No / Ethernet mode: Yes |
| Autonegotiation | Yes |
| Auto-MDI/MDIX | Yes |
| Interface IF4 | |
| Type | USB 1.1/2.0 |
| Variant | Type A |
| Max. output current | 0.5 A |
| Interface IF5 | |
| Type | USB 1.1/2.0 |
| Variant | Type A |
| Max. output current | 0.5 A |
| Interface IF6 | |
| Fieldbus | X2X Link master |
Electrical properties
| Electrical isolation | Ethernet (IF2), POWERLINK (IF3) and X2X (IF6) isolated from each other, from other interfaces and from PLC |
Operating conditions
| Mounting orientation | |
| Horizontal | Yes |
| Vertical | Yes |
| Installation elevation above sea level | |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature | |
| Operation | |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section "Derating". |
| Storage | -40 to 85°C |
| Transport | -40 to 85°C |
| Relative humidity | |
| Operation | 5 to 95%, non-condensing |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order application memory (CompactFlash) separately Backup battery included in delivery X20 end cover plate (right) included in delivery 12-pin X20 terminal block included in delivery Interface module slot covers included in delivery |
| Dimensions | |
| Width | 200 mm |
| Height | 99 mm |
| Depth | 85 mm |
| Weight | 470 g |