Wuhan Union Medical Technology Co., Ltd.
                                                                                                           
Verified Supplier
13 Years
Since 2013
Menu

Modular 15'' Vital Signs Patient Monitor With ETCO2 17 Languages

Price Negotiable
Price: Negotiable
MOQ: 1 unit
Delivery Time: 3-5 days
Brand: Union Medical
Product Description

Medical Hospital First-Aid 12 Inch Touchscreen Patient Monitor With Wifi Bluetooth

 

Model:PM9000D+
Screen: 15 inch

Features

3/5 lead ECG,suppot 7 ECG waveforms

Excellent ECG Anti-ESU, anti- defibrillator performanceUnique human voice alarm

Unique NIBP algorithm keep accuracy in all kinds of patient conditions

SpO2 have DSP algorithm and excellent performance when movement;

720 hours trend data and 2 hours wave data

Unique human voice alarm

USB WIFI module can easy connect to CMS
7 screen layouts: Standard, BigFont, Trend, OxyCRG, ECG Full-lead, OtherBed
Dynamic screen setting, every paramenters and waveforms can set open or closed and set color
USB WIFI module can easy connect to CMS
USB data output with software to view data on computer
Gas module can auto detect 5 anethesia gas type: HAL, ENF, ISO, SEV, DEV
Suport 17 languages include: English, French, German, Spanish, Portuguese, Russian and etc
USB data output with software to view data on computer
Moldular monitor has 4 slots inlucde: IBP, CO2, GAS and CSM/IoC

 

ECG Specifications

Lead mode: I,II,III,AVR,AVL,AVF,V

Gain:×0.25,×0.5,×1,×2

Heart rate:15-300BPM(Adult) 15-350BPM(Neonatal)

ST measurement Range:-2.0-+2.0mv Accuracy:±10%

Pacemaker: Yes

Sweep Speed:12.5mm/s,25mm/s,50mm/s

Bandwidth:
Diagnostic: 0.05~130Hz
Monitor: 0.5 ~40Hz
Surgery: 1~20Hz

 

SPO2 Specifications

Measure range: 0-100%

Resolution: 1%

Accuracy: 2%(70-100%)

Pulse Rate:20-250 BPM

Resolution: 1BPM

Accuracy:±3BPM

 

NIBP Specifications

Work Modes:Manual,Automatic,Continuous

Unit: mmHg,kPa

Measure range: 
 

Adult: SYS 40~280mmHg; DIA 10~225mmHg; MEAN 20~240mmHg
Pediatric: SYS 40~220mmHg; DIA 10~160mmHg; MEAN 20~170mmHg
Neonatal: SYS 40~135mmHg; DIA 10~100mmHg; MEAN 20~110mmHg

Resolution:1mmHg

Accuracy:±5mmHg

 

RESP Specifications

Measure range:0-150 BrPM

Resolution:1 BrPM

Accuracy: ±2%

 

TEMP Specifications

Measure range:0-50 ℃

Resolution:0.1 ℃

Accuracy: ±0.1℃

 


 

 
 
 
 
 
 
 
 
Union Medical Product Line:
 
Factory:
 
 
 
 
 
 
 
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Wuhan Union Medical Technology Co., Ltd.
Location BLD23, NO.5(1), DONGXIHU ROAD, NO.5647, DONGXIHU DISTRICT, WUHAN CITY, HUBEI, CHINA. (Unicode: 91420112303543774R)
Contact Person Alice Bai

Request A Quote

Please check your email address.
Your message must be at least 20 characters.