Portable Compact POCT HbA1c Analyzer Battery Integrated One Step Operation

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 10 work day
Brand: LABNOVATION
Product Description

HbA1c Analyzer Hematology Anlyzer LD-100 POCT HbA1c Testing One Step Operation HbA1c Analyzer

 

Intended Use

This instrument is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. HbA1c Analyzer is a semi-automatic instrument used to analyze glycated hemoglobin. It has the characteristics of small sample consumption and easy operation. It is suitable for the detection of HbA1c in medical units at all levels

Specifications

Model LD-100
Method Boronate Affinity
Operating Type 1-Step, fully automatic
Measurement Time Less than 3 minutes
Sample Type Whole blood
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Shelf-Life of Test Kit 9 months
Voltage 12VDC-3.33A
Sample Volume 4ul
Power connection Detachable power supply cord
Device category Fixed
Operating mode Continuous

 

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry.
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin.
  • Glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.

 

Feature

  • One-step Operation
  • Boronate Affinity
  • Battery Integrated
  • Portable, Compact
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

Performance Parameters

  • Accuracy:The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.
  • Permission: The authority is the first-level authority, and the login authority is the first-level authority

 

Certificated

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.