POCT One Step HbA1c Testing Analyzer Whole Blood Hemoglobin Analyzer LD-100

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 10 work day
Brand: LABNOVATION
Product Description

HbA1c Analyzer POCT One Step HbA1c Testing Analyzer LD-100 Hemoglobin Analyzer

 

Product application

This instrument is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood.

Specifications

Model LD-100
Method Boronate Affinity
Operating Type 1-Step, fully automatic
Measurement Time Less than 3 minutes
Sample Type Whole blood
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Dimensions 220(w)x150(L)x120(H)mm
Shelf-Life of Test Kit 9 months
Weight 800gs
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A

 

PRINCIPLE

HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells. The total concentration of hemoglobin depends on the initial reduced fluorescence signal. Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients. The percentage of glycosylated hemoglobin in total hemoglobin can be determined

 

Performance Indicators

  • Result reporting unit: Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
  • Accuracy: The relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision: Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity: In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.

 

Feature

  • One-step Operation
  • Battery Integrated
  • Portable, Compact
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port, LIS Support
     

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

 

Certificated

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.