LD-100 PPOCT HbA1c Auto Hematology Analyzer Machine 220mm*150mm*120mm

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 10 work day
Brand: LABNOVATION
Product Description

HbA1c Analyzer LD-100 (PPOCT) Fully Automatic HbA1c Testing Analyzer One Step Operation Analyzer

Intended Use

  • It is one of the Labnovation HbA1c Testing Analyzer
  • Intended for the content determination of hemoglobin A1c (HbA1c) in human whole blood.
  • Testing with 4μL sample,fast testing speed within 3min
  • Color touch screen easy to click and read the results
  • Protable and convience,suitable for the detection of HbA1c in medical units at all levels.

Specifications

Model LD-100
Measurement Time < 3 minutes
Sample Type Whole blood
Sample Volume 4ul
Data storage 7000
Method (Borate affinity)Fluorescent Immunoturbidimetry
Operating Type One-Step, fully automatic system
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Power connection Detachable power supply cord
Certificated NGSP, IFCC

 

 

Basic Parameters

  • Blood collection volume: The sampling volume of whole blood should not be less than 4μl.
  • Sample volume: 4μl full-blood.
  • Analytical wave-length: 510nm and 580nm.

Analysis Interface

Click the Analysis button on the main interface to enter the sample detection program. For details, see 5.3 Sample Detection

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • Simple Operation Step, One-Step Testing Process
  • Protable, Light and Small,Easy to carry
  • Working environment: Standard
  • Battery Integrated
  • Operating mode: Continuous
  • High Accuracy
  • RFID For Batch Management
  • Color Touch Screen
  • One Analyzer For HbA1c Testing

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

Performance Indicators

  • Accuracy: tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision: Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is within 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.
  • Permission: The authority is the first-level authority, and the login authority is the first-level authority.

 

Certificated

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.