12VDC 3.33A HbA1c Test Analyzer Small Light Haematology Analyzer Machine
Price:
Negotiation
MOQ:
1
Delivery Time:
10 work day
Brand:
LABNOVATION
Product Description
HbA1c Test Analyzer LD-100 Fully Automatic Hemoglobin Testing Analyzer One Step Testing HbA1c
Intended Use
LD-100 HbA1c Analyzer is intended for for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. LD-100 set up fully automatic system and color touch screen just need one step to click then start all testing. LD-100 is very small and light so it can suitable for the detection of HbA1c in medical units at all levels.
Specifications
| Model | LD-100 |
| Sample Type | Whole blood |
| Sample Volume | 4ul |
| Testing Time | Within 3 minutes |
| Data storage | 7000 |
| Power connection | Detachable power supply cord |
| Operating Condition | Temperature:15~35℃ Humidity:15~80%R.H |
| Measurement Range | HbA1c 4.0~15%(NGSP Unit) eAG 68-385mg/dl(mmol/l) |
| Storage Condition | Analyzer:10-60℃; Test kit: 2~8℃ |
| Voltage | 12VDC-3.33A |
| Analytical wave-length | 510nm and 580nm. |
| Input power | <60VA |
| Power supply | AC |
PRINCIPLE
- Uses the (borate affinity) fluorescent immunoturbidimetry
- Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
- The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
- The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
- Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
- The percentage of glycosylated hemoglobin in total hemoglobin can be determined.
Feature
- Fully Automatic System
- Protable, Convenient, Easy for use
- Fast test speed, Get the result within 3 min
- Battery Integrated
- Cv<3%, Excellent Correlation With HPLC
- RFID For Batch Management
- Color touch screen
Reliable
| IFCC calibrator | Normal | Abnormal | Normal | Abnormal |
| Mean HbA1c% | 5.4 | 9.6 | 5.3 | 9.2 |
| CV (%) | 2.5% | 1.9% | 2.4% | 1.8% |
Use Step
- Place cartridge in analyzer
- Push bead into reagents
- Insert sample into cartridge
Performance Parameters
- Accuracy:Relative deviation of the determination results of the analyzer should be within the range of ±8%.
- Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
- Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
- Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
- Functions of the analyzer:The function of report output in English; Abnormal alarm function.
- Result reporting unit: Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
- Functions of the analyzer: The function of report output in English; Abnormal alarm function.
Certificated
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.