Hospital Medical HbA1c Test Analyzer 4ul Sample Automated Haematology Analyzer

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 10 work day
Brand: LABNOVATION
Product Description

HbA1c Test Analyzer LD-100 Fully Automatic Testing Hematogy Analyzer Medical Use HbA1c Analyzer

 

Intended Use

This instrument is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. Testing processis very simple, touch screen for start testing by click. The LD-100 HbA1c Analyzer is a semi-automatic instrument used to analyze glycated hemoglobin. It just need small sample the can do the HbA1c tetsing, very esay operation and it is suitable for the detection of HbA1c in medical units at all levels.

Specifications

Model LD-100
Sample Type Whole blood
Weight 800gs
Sample Vloum 4ul
Method Fuorescent immunoturbidimetry
Operating Type Fully automatic testing
Measurement Time  within 3 minutes
Sample Type Whole blood
Data storage 7000
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Dimensions 220(w)x150(L)x120(H)mm
Shelf-Life of Test Kit 9 months
Power connection Detachable power supply cord
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A

 

PRINCIPLE
HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.

 

Performance Parameters

  • Accuracy:The relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.

 

Feature

  • Boronate Affinity
  • Battery Integrated
  • Portable, Compact
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • External printer (Blue-tooth)
  • USB Port, LIS Support
  • Operating mode: Continuous
  • Easy for use

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

 

Certificated

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.