Small Sample Fully Automated Hematology Analyzer Professional
HbA1c Analyzer LD-560 Fully Automatic Hemoglobin Testing Analyzer For Professional Test Use
Intended Use
- The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
- This analyzer is a fully automated instrument used to analyze glycosylated hemoglobin. It has the characteristics of small sample amount and simple operation. It is suitable for the detection of glycosylated hemoglobin in medical institutions.
Specifications
| Name |
Fully Automated HbA1c Analyzer |
| Model | LD-560 |
| Method | HPLC(High Performance Liquid Chromatography) |
| Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
| Test Speed | 90 seconds per test |
| Wavelength | 420nm |
| Sample Type | Whole Blood, Pre-diluted blood |
| Autoloader Capacity | 20 tubes |
| Precision | CV<2% |
| Column Capacity | 3000 tests |
| Working Condition | Temperature: 15-30℃ |
| Net weight | 28kg |
| Storage environment: Temperature | -20℃~55℃ |
| Humidity | 10%~93% |
| Power supply type | AC |
| Operating conditions | Continuous |
| Input power |
300VA |
Principle
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non-glycosylated hemoglobin has a positive charge.According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single-wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.
Feature
- Information Input
- Sample Dispense
- Automatic Detection
- Result Output
- Easy Operation
- Fast Testing Speed
Advantage
- Autoloader for 20 tubes
- One click to start testing
- Easy to change reagents
- Fully-automated solution
- No sample pre-treatment needed
Performance Parameters
-
Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
-
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.
-
Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
-
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
Certificated