50Hz 60Hz 3000 Tests HbA1c Test Analyzer HPLC Detection Haematology Analyser
HbA1c Test Analyzer Fully Automatic HbA1c Analyzer LD-560 HPLC Detection Hematology Analyzer
Intended Use
- The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
- The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.
Specifications
| Name |
Fully Automated HbA1c Analyzer |
| Model | LD-560 |
| Method | HPLC(High Performance Liquid Chromatography) |
| Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
| Test Speed | 90 seconds per test |
| Wavelength | 420nm |
| Sample Type | Whole Blood, Pre-diluted blood |
| Autoloader Capacity | 20 tubes |
| Precision | CV<2% |
| Column Capacity | 3000 tests |
| Working Condition | Temperature: 15-30℃ |
| Net weight | 28kg |
| Storage environment: Temperature | -20℃~55℃ |
| Humidity | 10%~93% |
Principle
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger. According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single-wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.
Feature
- Information Input
- Sample Dispense
- Automatic Detection
- Result Output
- Easy Operation
- Fast Testing Speed
Advantage
- HPLC Method
- Full Automation
- Smart System
- Best Quality And Performance
- Most Cost-effective
Performance Parameters
-
Repeatability: For samples with a test concentration of 4%-6%, the sample coefficient of variation (CV) of the test results is not greater than 2.0%.
-
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.
-
Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
-
Linear range: Within the range of 3%-18% of glycosylated hemoglobin, the linear correlation coefficient R value of the test results should not be less than 0.9900
-
Basic function: Provides Chinese report and abnormal alarm.
Certificated
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.