Universal IVD Dengue NS1 Antigen Detection Kit Immunochromatography

Price Negotiable
Price: US$0.4-0.8/pcs
MOQ: 10000/Pcs
Delivery Time: 5-7 work day
Brand: LABNOVATION
Product Description

Rapid Test Kit Dengue NS1 Antigen Detection Test Kit High Accuracy Medical One Step Rapid Test Kit

 

Intenden Use

The Dengue NS1 Antigen Rapid Test Kit is intended for the qualitative detection of dengue virus NS1 antigen to dengue virus in serum/plasama/whole blood to aid in the diagnosis of Dengue virus infection.

Specifications

Test Item Dengue NS1 Antigen Rapid Test Kit
Number  LQ-000102
Package Size 25 Test /Kit
Sample Type Serum, Plasma, Whole Blood
Sample Volume 3 Drops(80μl-100μl)
Product Shelf Life 24 Months
Test Speed Within 15 minutes
Storage Condition Store 2-30℃
Method  Immunochromatography
Sensitivity 97.92%
Specificity 99.02%
Accuracy 98.67%

Analytical Resualts

  • Specificity: 99.02%
  • Sensitivity: 97.92%
  • Accuracy: 98.67%

Main Components

  • Test Cassettes
  • Disposable Pipettes
  • Specimen Buffer
  • Instruction For Use

Material Needed But Not Provided

  • Specimen Collection Containers
  • Centrifuge (for serum/plasma sample)
  • Timer

Use Step

  • Take off the outer packing, put the cassette onto the desk with the sample window up.
  • Drop 3 drops (80μl-100μl) of serum/plasma/whole blood vertically into the sample well of cassette. If the whole blood sample is thick, add 1 drop (40-50μl) of specimen buffer into the sample well of cassette.
  • Observe the test results immediately within 15-20 minutes, the result is invalid after 20 minutes.

Interpreation Of Result

  • POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (T).

  • INVALID: No red lines appear or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

Limitations

  • The results of the reagent are only for clinical reference, which is not the only basis for clinical diagnosis and treatment.
  • A confirmed diagnosis and treatment should only be made by a physician after all clinical and laboratory findings have been evaluated.
  • Cannot be used for screening the general population, but can only be used for the screening of patients with clinical symptoms or when there is suspicious exposure.
  • The best time for dengue testing is 6 ~ 14 days after the symptom of fever.
  • Do not use other kinds of quality control sample to test the reagent. Components of different batches cannot be exchanged for use to avoid erroneous results.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.