IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: 5-7 work day
Brand: LABNOVATION
Product Description

Hematology Analyzer Reagents Hematology Reagent For Erma Pce-210 Analyzers High Quality

 

Intended Use

The hematology ana;yzer reagents to be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Erma PCE-210 hematology analyzers. This product is for In Vitro Diagnostic Use only.

 

Specification

80-10-020 DILUENT CM 20L
80-30-005 LYSE CM 500mL
80-40-001 CLEANER CM 1L

 

Kit Composistion

DILUENT CM NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
LYSE CM Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
CLEANER CM

Buffer<0.3%, Proteolytic Enzyme<0.2%

 

Applicable Insteument

For use with Erma PCE-210 hematology analyzers.

 

Procedures

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.

Storage

Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.

 

Precautions

  1. Re-calibration is recommended when changing the origin of the reagents.
  2. It is not recommended using different brands of solutions together on one unit of analyzer.
  3. Do not ingest. Avoid contact with skin and eyes.
  4. Skin contact: Flush with plenty of water.
  5. Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  6. This kit is for professionals and in vitro diagnostic use only.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.