Labnovation Technologies, Inc.
                                                                                                           
Verified Supplier
25 Years
Since 2001
Menu

Hospitex Hema Screen Analyzer Hematology Reagents For WBC Differentiation

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Hematology Analyzer Reagents Hematology Reagent For Hospitex Hema Screen Analyzers

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Hospitex Hema Screen hematology analyzers. This product is for In Vitro Diagnostic Use only.

 

Specification

L-70010070 DILUENT HX 20L
L-70010075 LYSE HX 500ml
L-70010085 CLEANER HX 5L

Kit Composition

DILUENT HX NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
LYSE HX Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
CLEANER HX

Sodium Sulfate<1.5%, Anti-microbial Agent<0.1%

Application

For use with Hospitex Hema Screen hematology analyzers.

 

Procedures

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.

Storage

Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.

 

Precautions

  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.