Liquid Hematology Analyzer Reagents For HYCEL CELLY 18 CELLY 70

Price Negotiable
Price: US$8-12/Pieces
MOQ: 500 Pieces
Delivery Time: 10 work day
Brand: LABNOVATION
Product Description

Hematology Analyzer Reagents Hycel Celly Hematology Reagent For HYCEL CELLY 18, CELLY 70 Analyzers

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Hycel Celly 18, CELLY 70 hematology analyzers. This product is for In Vitro Diagnostic Use only.

 

APPLICABLE INSTUMENT

For use with Hycel Celly 18, Celly 70 hematology analyzers.

 

Specification

90-10-020 DILUENT CEL 20L
90-20-020 RINSE CEL 20L
90-30-001 LYSE CEL 1L
90-40-001 CLEANER CEL 1L

 

KIT COMPOSITION

DILUENT CEL

NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1%

RINSE CEL Sodium Sulfate Anhydrous<2.0%
LYSE CEL Quaternary Ammonium Sal t<10% Sodium Lauryl Sulfate <1.5%
CLEANER CEL

Buffer<0.5%, Proteolytic Enzyme<0.5%

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Procedures 

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.
Advantage
  • One source for all brands of analyzer
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand

Storage

90-10-020 DILUENT CEL 24 months 60 days
90-20-020 RINSE CEL 24 months 30 days
90-30-001 LYSE CEL 24 months 60 days
90-40-001 CLEANER CEL 18 months 30 days
  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.

 

PRECAUTIONS
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

FAQ

  • About MOQ?

We have the limit order which is 10000, we would like to cooperate with you, don't worry about MOQ, just send us of your what items you want order.

  • What is your lead time?

Stock 3-7 days in general. Or please contact us by email for specific lead time base on your order quantities.

  • Accept OEM or ODM order?

Yes, we accept both OEM and ODM for customers.

  • What are your terms of delivery?

We can accept EXW, FOB, CIF, etc. You can choose one which is the most convenient for you.

  • Manufacturer or Trade Company?

We're Manufacturer.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.